Error Message
Possible cause
Fault elimination
Error
Error text
53
STBY I HIGH
This alarm occurs two ways:
1) In the initial rest state after key
on, if the outputs of the current
amplifiers are not comprised in the
window 2.2 to 2.8 Vdc.
2) After the initial diagnosis this
alarm occurs when the outputs of
the current amplifiers at rest have a
drift larger than ±0.15 V.
It is necessary to replace
the controller.
61
HIGH TEMPERATURE
T h i s a l a r m o c c u r s i f t h e
temperature of the controller base
plate overtakes 75 degrees.
Improve the cooling of the
controller; otherwise it is
necessary to replace the
controller.
65
MOTOR TEMPERAT.
This alarm occurs only when DIAG
MOTOR TEMP is on and the
thermal sensor inside the motor
measures a temperature higher
than 150 degrees. It occurs also
when trying to acquire the motor
resistance with a temperature in the
motor higher than 150 degree
(still with DIAG MOTOR TEMP to
ON).
Check the thermal sensor in
the motor is right working. If
it is, improve the cooling of
the motor.
70
HIGH CURRENT
This alarm occurs if the circuit to
limit via hardware the current in the
motor is either always active at key-
on or repeatedly active when the
motor is turning.
Check the motor is suited to
work with the eps-ac0 (not
oversized). Otherwise it is
necessary to replace the
controller.
71
POWER FAILURE #3
This alarm occurs when the current
in the phase V of the motor is zero
and the motor is commanded for
moving.
Check the power fuse is OK.
Check the battery positive
arrives to the controller.
Check the continuity of
the wire in the phase V of
the motor. Otherwise it is
necessary to replace the
controller.
72
POWER FAILURE #2
This alarm occurs when the current
in the phase U of the motor is zero
and the motor is commanded for
moving.
Check the power fuse is OK.
Check the battery positive
arrives to the controller.
Check the continuity of
the wire in the phase U of
the motor. Otherwise it is
necessary to replace the
controller.
Содержание LIST JX0
Страница 1: ...Service Manual JX0 Task Support Vehicle...
Страница 2: ...Service Manual Task Support Vehicle JX0...
Страница 14: ...1 1 1 INFORMATION SPECIFICATIONS...
Страница 15: ...2 NOTE...
Страница 23: ...10 2 2 MAINTENANCE...
Страница 24: ...11 NOTE...
Страница 34: ...21 3 3 STRUCTURE FUNCTIONS...
Страница 35: ...22 NOTE...
Страница 45: ...32 4 4 CHASSIS SYSTEM...
Страница 46: ...33 NOTE...
Страница 50: ...37 5 5 DRIVE SYSTEM...
Страница 51: ...38 NOTE...
Страница 68: ...55 6 6 OPERATING SYSTEM...
Страница 69: ...56 NOTE...
Страница 83: ...70 7 7 HYDRAULIC SYSTEM...
Страница 84: ...71 NOTE...
Страница 86: ...73 REV 07 2019 HYDRAULIC SYSTEM 7 7 1 1 Hydraulic Schematic Diagram...
Страница 99: ...86 8 8 ELECTRICAL SYSTEM...
Страница 100: ...87 NOTE...
Страница 130: ...REV 07 2019 ELECTRICAL SYSTEM 8 117 operational...
Страница 169: ...REV 07 2019 ELECTRICAL SYSTEM 8 156 8 16 Electrical Schematic Diagrams...
Страница 170: ...REV 07 2019 ELECTRICAL SYSTEM 8 157...
Страница 171: ...REV 07 2019 ELECTRICAL SYSTEM 8 158 8 17 Wiring Harness and Connectors TO Handheld unit communication cable...
Страница 172: ...REV 07 2019 ELECTRICAL SYSTEM 8 159...
Страница 173: ...160 9 9 TROUBLESHOOTING...
Страница 174: ...161 NOTE...
Страница 179: ...166 APPENDIX...
Страница 180: ...167 NOTE...
Страница 181: ...168 A A SERVICE MANUAL MAST...
Страница 182: ...169 NOTE...
Страница 185: ...172 REV 07 2019 SERVICE MANUAL MAST A...
Страница 187: ...174 REV 07 2019 SERVICE MANUAL MAST A...
Страница 190: ...177 B B SERVICE MANUAL BATTERY...
Страница 191: ...178 NOTE...
Страница 204: ...191 C C SCHEDULE...
Страница 205: ...192 NOTE...