REV. 07/2019
ELECTRICAL SYSTEM
8
134
Error Message
Possible cause
Fault elimination
Error
Error text
79
INCORRECT START
"Incorrect starting sequence.
Possible reasons for this alarm are:
1- A travel demand active at key-
on.
2- Man-presence sensor active at
key on."
"1- Check wirings.
2- Check microswitches for
failures.
3- Through the TESTER
function, check the states of
the inputs are coherent with
microswitches states.
4- If the problem is not solved,
replace the logic board."
80
FORW + BACK
This alarm occurs when both the
travel requests (FW and BW) are
active at the same time.
"1- Check that travel requests
are not active at the same time.
2- Check the FW and BW input
states through the TESTER
function.
3- Check the wirings relative to
the FW and BW inputs.
4- Check if there are failures in
the microswitches.
5- If the problem is not solved,
replace the logic board."
142
WAIT ACTIVATION
if downlaod a SW with activation
function,but haven't do any
activation before,the alarm occrus
do activation with EP TOOLS
143
WRONG
PASSWORD
if the EP PASSWORD function is
active but haven't enter the correct
password,the alarm occurs
"1-enter the correct password
2-disable the password function"
144
NO CAN DISP EP
When the truck is running, if the
DISPLAY TYPE=5,but the controller
lose the communication with EP
DISPLAY,this alarm occurs
"1-check the communication
wiring between EP DISPLAY
and controller
2-check if the EP DISPLAY is
broken"
145
WAIT DISP EP
if the DISPLAY TYPE=5,but the
controller can't get message from
EP DISPLAY when the truck
start,this alarm occurs
"1-check the communication
wiring between EP DISPLAY
and controller
2-check if the EP DISPLAY is
broken
3-try to set the DISPLAY TYPE
into a correct value"
146
RENTAL TIMEOUT
if the rental function is actived,but
the rental enable time is run out,this
alarm occurs
"1-check the rental hour left in
TESTER menu
2-use EP TOOLS to disable the
rental function"
147
NO CAN BMS EP
if the communication between BMS
and controller is out of time,this
alarm occurs
"1-check the communication
wiring between BMS and controller
2-there's a fault on BMS can
device,repalce the BMS"
Содержание LIST JX0
Страница 1: ...Service Manual JX0 Task Support Vehicle...
Страница 2: ...Service Manual Task Support Vehicle JX0...
Страница 14: ...1 1 1 INFORMATION SPECIFICATIONS...
Страница 15: ...2 NOTE...
Страница 23: ...10 2 2 MAINTENANCE...
Страница 24: ...11 NOTE...
Страница 34: ...21 3 3 STRUCTURE FUNCTIONS...
Страница 35: ...22 NOTE...
Страница 45: ...32 4 4 CHASSIS SYSTEM...
Страница 46: ...33 NOTE...
Страница 50: ...37 5 5 DRIVE SYSTEM...
Страница 51: ...38 NOTE...
Страница 68: ...55 6 6 OPERATING SYSTEM...
Страница 69: ...56 NOTE...
Страница 83: ...70 7 7 HYDRAULIC SYSTEM...
Страница 84: ...71 NOTE...
Страница 86: ...73 REV 07 2019 HYDRAULIC SYSTEM 7 7 1 1 Hydraulic Schematic Diagram...
Страница 99: ...86 8 8 ELECTRICAL SYSTEM...
Страница 100: ...87 NOTE...
Страница 130: ...REV 07 2019 ELECTRICAL SYSTEM 8 117 operational...
Страница 169: ...REV 07 2019 ELECTRICAL SYSTEM 8 156 8 16 Electrical Schematic Diagrams...
Страница 170: ...REV 07 2019 ELECTRICAL SYSTEM 8 157...
Страница 171: ...REV 07 2019 ELECTRICAL SYSTEM 8 158 8 17 Wiring Harness and Connectors TO Handheld unit communication cable...
Страница 172: ...REV 07 2019 ELECTRICAL SYSTEM 8 159...
Страница 173: ...160 9 9 TROUBLESHOOTING...
Страница 174: ...161 NOTE...
Страница 179: ...166 APPENDIX...
Страница 180: ...167 NOTE...
Страница 181: ...168 A A SERVICE MANUAL MAST...
Страница 182: ...169 NOTE...
Страница 185: ...172 REV 07 2019 SERVICE MANUAL MAST A...
Страница 187: ...174 REV 07 2019 SERVICE MANUAL MAST A...
Страница 190: ...177 B B SERVICE MANUAL BATTERY...
Страница 191: ...178 NOTE...
Страница 204: ...191 C C SCHEDULE...
Страница 205: ...192 NOTE...