Error Message
Possible cause
Fault elimination
Error
Error text
28
PUMP VMN LOW
The pump motor output is lower
than expected, considering the
PWM duty cycle applied.
"A) If the problem occurs at start up
(the LC does not close at all), check:
- Motor internal connections;
- Motor power cables connections;
- If the motor connection are OK,
the problem is inside the controller.
B) If the problem occurs after
closing the LC (the LC closes and
then opens back again), check:
- Motor internal connections;
- If motor windings/cables have
leakages towards truck frame;
- If no problem are found on the motors,
the problem is inside the controller.
C) If the alarm occurs during motor
running, check:
- Motor internal connections;
- If motor windings/cables have
leakages towards truck frame;
- That the LC power contact closer
properly, with a good contact;
- If no problem are found on the
motors, the problem is inside the
controller, it is necessary to replace
the logic board."
29
PUMP VMN HIGH
This test is carried out when the
pump motor is turning (PWM
applied). The pump motor output is
higher than expected, considering
the PWM applied.
" -Motor internal connections
-If motor windings/cables have
leakages towards truck frame
-If no problem are found on the
motors, the problem is inside the
-controller, it is necessary to
replace the logic board."
30
VMN LOW
"Start-up test. Before switching
the LC on, the software checks
the power bridge: it turns on
alternatively the high-side power
MOSFETs and expects the phase
voltages increase toward the
positive rail value. If one phase
voltage is lower than a certain
percentage of the rail voltage, this
alarm occurs.
Motor running test. When the
motor is running, the power
bridge is on and the motor voltage
feedback tested; if it is lower than
expected value (a range
of values is considered), the
controller enters in fault state."
"If the problem occurs at start
up (the LC does not close at
all), check:
- motor internal connections
(ohmic continuity);
- motor power-cables connections;
- if the motor connections are
OK, the problem is inside the
controller; replace it.
If the alarm occurs while the
motor is running, check:
- motor connections;
- that the LC power contact
closes properly, with a good
contact;
- if no problem is found, the
problem is inside the controller.
Replace it."
Содержание LIST JX0
Страница 1: ...Service Manual JX0 Task Support Vehicle...
Страница 2: ...Service Manual Task Support Vehicle JX0...
Страница 14: ...1 1 1 INFORMATION SPECIFICATIONS...
Страница 15: ...2 NOTE...
Страница 23: ...10 2 2 MAINTENANCE...
Страница 24: ...11 NOTE...
Страница 34: ...21 3 3 STRUCTURE FUNCTIONS...
Страница 35: ...22 NOTE...
Страница 45: ...32 4 4 CHASSIS SYSTEM...
Страница 46: ...33 NOTE...
Страница 50: ...37 5 5 DRIVE SYSTEM...
Страница 51: ...38 NOTE...
Страница 68: ...55 6 6 OPERATING SYSTEM...
Страница 69: ...56 NOTE...
Страница 83: ...70 7 7 HYDRAULIC SYSTEM...
Страница 84: ...71 NOTE...
Страница 86: ...73 REV 07 2019 HYDRAULIC SYSTEM 7 7 1 1 Hydraulic Schematic Diagram...
Страница 99: ...86 8 8 ELECTRICAL SYSTEM...
Страница 100: ...87 NOTE...
Страница 130: ...REV 07 2019 ELECTRICAL SYSTEM 8 117 operational...
Страница 169: ...REV 07 2019 ELECTRICAL SYSTEM 8 156 8 16 Electrical Schematic Diagrams...
Страница 170: ...REV 07 2019 ELECTRICAL SYSTEM 8 157...
Страница 171: ...REV 07 2019 ELECTRICAL SYSTEM 8 158 8 17 Wiring Harness and Connectors TO Handheld unit communication cable...
Страница 172: ...REV 07 2019 ELECTRICAL SYSTEM 8 159...
Страница 173: ...160 9 9 TROUBLESHOOTING...
Страница 174: ...161 NOTE...
Страница 179: ...166 APPENDIX...
Страница 180: ...167 NOTE...
Страница 181: ...168 A A SERVICE MANUAL MAST...
Страница 182: ...169 NOTE...
Страница 185: ...172 REV 07 2019 SERVICE MANUAL MAST A...
Страница 187: ...174 REV 07 2019 SERVICE MANUAL MAST A...
Страница 190: ...177 B B SERVICE MANUAL BATTERY...
Страница 191: ...178 NOTE...
Страница 204: ...191 C C SCHEDULE...
Страница 205: ...192 NOTE...