Proline Promag 51
3 Installation
Hauser
23
3.2.7
Nominal flow rate (Metrological classes)
The diameter of the pipe usually governs the nominal diameter of the sensor. The plant should be
designed so that under “normal” operating conditions, the optimum flow rate lies between
2...3 m/s.
If it is necessary to increase the flow velocity, this can be done by reducing the nominal diameter of
the sensor (see Section 3.2.6).
Please indicate the following data in all requests and orders for certified devices:
Nominal flow rate (Qn) for Class A or B
This information is shown on the nameplate and must be given in the order text. Q
n
must lie
between the corresponding Q
n
(min) and Q
n
(max) valid for Class A or B.
Current output / pulse output
For scaling the current output, the scale value and if required the pulse output value must be given,
and will then set at the factory.
The full scale value and the value Q
n
are two different values. For example, the full scale value
can be higher than the defined Q
n
. In extreme cases, it is double the value of Q
n
(max) and lies
at 10 m/s.
Nominal flow rate Q
n
in [m
3
/h]
Nominal
Diameter DN
Metrological class
A
Metrological class
B
[mm]
Qn (min)
Qn (max)
Qn (min)
Qn (max)
15
0.8
Q
mi
n
: Q
n
= 1 :
2
5
3.0
1.6
Q
mi
n
:
Q
n
=
1 : 50
3.0
25
2.2
8.8
4.4
8.8
32
3.6
14.0
7.2
14.0
40
5.6
22.6
11.3
22.6
50
9.0
35.0
15.0 *
Q
mi
n
:
Q
n
=
1 :
3
3
35.0
65
15.0
60.0
20.0
60.0
80
15.0 *
Q
mi
n
:
Q
n
=
1 :
1
2
.5
90.0
30.0
90.0
100
18.0
140.0
46.0
140.0
125
28.0
220.0
73.0
220.0
150
40.0
320.0
105.0
320.0
200
70.0
550.0
190.0
550.0
250
110.0
880.0
290.0
880.0
300
160.0
1250
420.0
1250
350
215.0
1700
570.0
1700
400
280.0
2200
750.0
2200
500
440.0
3000
1170
3000
600
640.0
3000
1700
3000
700...2000
Diameters DN 700...2000 can also be approved.
However, measuring points with these diameters are not normally subject to metrological regulations
(Qmax = 2 x Qn > 2000 m
3
/h).
* Limit range Q
≥
15 m
3
/h (see also Table on Page 74)
Qn (min) = lowest nominal flow rate with reference to Q (min), v = 0.5 m/s
Qn (max) = highest nominal flow rate with reference to Q (max), v = 5 m/s
Designations
Содержание Proline Promag 51
Страница 4: ...QUICK SETUP commissioning Proline Promag 51 4 Endress Hauser...
Страница 10: ...1 Safety instructions Proline Promag 51 10 Endress Hauser...
Страница 52: ...4 Wiring Proline Promag 51 52 Endress Hauser...
Страница 80: ...7 Maintenance Proline Promag 51 80 Endress Hauser...
Страница 104: ...9 Trouble shooting Proline Promag 51 104 Endress Hauser...
Страница 122: ...11 Index Proline Promag 51 122 Endress Hauser...
Страница 124: ...www endress com worldwide BA080D 06 en 03 05 50101924 FM SGML6 0...