Proline Promag 51
3 Installation
Hauser
17
3.2
Installation conditions
3.2.1
Dimensions
All the dimensions and lengths of the sensor and transmitter are provided in the separate
documentation “Technical Information”.
3.2.2
Mounting location
Correct measuring is possible only if the pipe is full. Avoid the following locations:
• Highest point of a pipeline. Risk of air accumulating
• Directly upstream a free pipe outlet in a vertical pipeline.
F06-5xxxxxxx-11-00-00-xx-000
Fig. 7:
Location
Installation of pumps
Do not install the sensor on the intake side of a pump. This precaution is to avoid low pressure
and the consequent risk of damage to the lining of the measuring tube. Information on the lining's
resistance to partial vacuum can be found on
It might be necessary to install pulse dampers in systems incorporating reciprocating, diaphragm
or peristaltic pumps. Information on the measuring system's resistance to vibration and shock
can be found on
F06-5xxxxxxx-11-00-00-xx-001
Fig. 8:
Installation of pumps
Содержание Proline Promag 51
Страница 4: ...QUICK SETUP commissioning Proline Promag 51 4 Endress Hauser...
Страница 10: ...1 Safety instructions Proline Promag 51 10 Endress Hauser...
Страница 52: ...4 Wiring Proline Promag 51 52 Endress Hauser...
Страница 80: ...7 Maintenance Proline Promag 51 80 Endress Hauser...
Страница 104: ...9 Trouble shooting Proline Promag 51 104 Endress Hauser...
Страница 122: ...11 Index Proline Promag 51 122 Endress Hauser...
Страница 124: ...www endress com worldwide BA080D 06 en 03 05 50101924 FM SGML6 0...