Sanitary compatibility
Drinking water suitability, WRAS - Approved Product, KTW
(for hard rubber)
Pressure Equipment Directive
Measuring devices with a nominal diameter smaller than or equal to DN 25 correspond to
Article 3(3) of the EC Directive 97/23/EC (Pressure Equipment Directive) and have been designed
and manufactured according to good engineering practice. Where necessary (depending on the
medium and process pressure), there are additional optional approvals to Category II/III for larger
nominal diameters.
CE mark
The measuring system is in conformity with the statutory requirements of the EC Directives.
Hauser confirms successful testing of the device by affixing to it the CE mark.
Other standards and
guidelines
EN 60529
Degrees of protection by housing (IP code)
EN 61010
Protection Measures for Electrical Equipment for Measurement, Control,
Regulation and Laboratory Procedures
EN 61326/A1 (IEC 6326)
Electromagnetic compatibility (EMC requirements)
NAMUR NE 21
Electromagnetic compatibility (EMC) of industrial process and laboratory control equipment.
NAMUR NE 43
Standardisation of the signal level for the breakdown information of digital transmitters with
analogue output signal.
NAMUR NE 53
Software of field devices and signal-processing devices with digital electronics.
Regulations for custody transfer:
– Allgemeine Vorschriften (AV) zur Eichordnung (EO)
– Anlage 6 zur Eichordnung (EO 6-1): Vorschriften für Volumen-Messgeräte
für strömendes Wasser
– PTB-A6.1: Volumen-Messgeräte für Kaltwasser
10.1.11 Ordering information
The Hauser service organisation can provide detailed ordering information and informa-
tion on specific order codes on request.
The following values are to be stated when ordering an instrument with “Custody transfer
approval”:
• Nominal flow rate Q
n
• Metrological Class
• If a certified pulse output is required for the custody transfer mode:
Pulse value, pulse width, output signal type (passive-positive, passive-negative)
The flowmeter is delivered with appropriate factory settings if no information is given on the
full scale value for current output, the current range (0/4...20 mA), pulse value, display mode or
totalizer units!
Содержание Proline Promag 51
Страница 4: ...QUICK SETUP commissioning Proline Promag 51 4 Endress Hauser...
Страница 10: ...1 Safety instructions Proline Promag 51 10 Endress Hauser...
Страница 52: ...4 Wiring Proline Promag 51 52 Endress Hauser...
Страница 80: ...7 Maintenance Proline Promag 51 80 Endress Hauser...
Страница 104: ...9 Trouble shooting Proline Promag 51 104 Endress Hauser...
Страница 122: ...11 Index Proline Promag 51 122 Endress Hauser...
Страница 124: ...www endress com worldwide BA080D 06 en 03 05 50101924 FM SGML6 0...