3 Installation
Proline Promag 51
20
Hauser
Inlet and outlet runs
If possible, install the sensor well clear of fittings such as valves, T-pieces, elbows, etc. Compliance
with the following requirements for the inlet and outlet runs is necessary in order to ensure
measuring accuracy.
• Inlet run
≥
5 x DN
• Outlet run
≥
2 x DN
"
Caution!
• The inlet run and the outlet run must have the same nominal width as the flowmeter!
• This data is applicable even with the use of adapters to increase fluid velocity (see Page 22).
F06-5xxxxxxx-11-00-00-xx-005
Fig. 13:
Inlet and outlet runs
3.2.4
Vibrations
Secure the piping and the sensor if vibration is severe.
"
Caution!
It is advisable to install sensor and transmitter separately if vibration is excessively severe.
Information on resistance to vibration and shock can be found on
→
F06-5xxxxxxx-11-00-00-xx-006
Fig. 14:
Measures to prevent vibration of the measuring device
> 10 m