Mounting
Micropilot S FMR531 with HART/4...20 mA
22
E Hauser
3.4.4
Mounting with Roof reflector
Reflektor
For high precision applications, measurements from a floating roof are inadvisable due to the
unsteady movements of the floating roof. For floating roof applications, a special reflector can be
used.
!
Note!
The roof reflector is not part of the standard offering from Hauser.
L00-FMR53xxx-06-00-00-en-002
Construction hints
• The construction serves as retroreflector such that a tank roof incline does not influence the
measured value.
• The cross-sectional area shouldn‘t be smaller than specified in the figure above to receive and
transmit enough energy.
• The construction should be open in the bottom part to allow rainwater to drop out. Thin stainless
steel sheets should be used, to prevent the construction from becoming too heavy.