Appendix
Micropilot S FMR531 with HART/4...20 mA
94
E Hauser
Micropilot S radar devices continuously monitor the compliance with accuracyrequirements for
custody transfer measurements according to OIML R85. If, for example, the accuracy cannot be
maintained due to quick surface movements, this is reported via a separate alarm in the local display
(displays "#"- symbols) and via digital communication.
11.3.6
Definition of terms
For definitions and procedures please refer to the following documents:
• Manual of Petroleum Measurement Standards, Chapter 3 - Tank Gauging,
Section 1.B - Standard Practice for Level Measurement of Liquid Hydrocarbons in Stationary
Tanks by Automatic Tank Gauging, American Petroleum Institute, second edition, 2001
• OIML R 85, Organisation Internationale de Métrologie Légale, International Recommendation R
85, edition 1998 (E).
11.3.7
Integrated in tank gauging system
The Hauser Tank Side Monitor NRF590 provides integrated communications for sites with
multiple tanks, each with one or more sensors on the tank, such as radar, spot or average
temperature, capacitive probe for water detection and/or pressure sensors. Multiple protocols out
of the Tank Side Monitor guarantee connectivity to nearly any of the existing industry standard tank
gauging protocols. Optional connectivity of analog 4...20 mA sensors, digital I/O and analog output
simplify full tank sensor integration. Use of the proven concept of the intrinsically safe HART bus
(HART multidrop) for all on-tank sensors yields extremely low wiring costs, while at the same time
providing maximum safety, reliability and data availability.
L00-FMR53xxx-14-00-06-en-006
Micro
p
i
l
ot
S
Prothermo
T
ank
Side
Monitor
T
ank
Scanner
NXA8
2
0
NXA8
2
0
Data
Concentrator
T
CP
/I
P
NXA8
2
0
H
ost
Link
Pressure
HART
4 wire
Supply voltage:
16…253 VAC
DCS
T
ankvision
workstation
Содержание Micropilot S FMR531
Страница 4: ...Brief overview Micropilot S FMR531 with HART 4 20 mA 4 Endress Hauser ...
Страница 87: ...Micropilot S FMR531 with HART 4 20 mA Technical data Endress Hauser 87 ...
Страница 98: ...Micropilot S FMR531 with HART 4 20 mA Index 98 Endress Hauser ...
Страница 100: ...www endress com worldwide BA207F 00 en 04 09 71093754 CCS FM SGML 6 0 ProMoDo 71093754 ...