Wiring
Micropilot S FMR531 with HART/4...20 mA
26
E Hauser
4.2
Connecting the measuring unit
Terminal compartment
The housing features a separate terminal compartment.
L00-FMR53xxx-04-00-00-en-001
Load HART
Minimum load for HART communication: 250
Ω
Cable entry
Cable gland: 2 x M20x1.5
Cable entry: 2 x G ½ or 2 x ½ NPT
Supply voltage
DC voltage: 16…36 VDC
Power consumption
Max. 330 mW at 16 V, max. 500 mW at 24 V, max. 600 mW at 30 V.
Current consumption
Max. 21 mA (50 mA inrush current).
Communication
Terminal voltage
minimum
maximum
Power supply
Standard
U (20 mA) =
16 V
36 V
Ex
U (20 mA) =
16 V
30 V
Signal
Ex
U (4 mA) =
11.5 V
30 V
U (20 mA) =
11.5 V
30 V
1
3
2
4
4
5
5
1
3
2
4
5
power suppl
y
signal