Micropilot S FMR531 with HART/4...20 mA
Trouble-shooting
E Hauser
71
9.2
System error messages
Code
Description
Possible cause
Remedy
A102
checksum error
general reset & new
calibr.required.
device has been powered off before data
could be stored;
emc problem
E
2
PROM defect
reset
avoid emc problem;
if alarm prevails after reset,
exchange electronics
W103
initialising - please
wait
E
2
PROM storage not yet finished
wait some seconds; if warning
prevails, exchange electronics
A106
downloading please wait
processing data download
wait until warning disappears
A110
checksum error
general reset & new
calibr.required.
device has been powered off before data
could be stored
emc problem
E
2
PROM defect
Reset
avoid emc problem;
if alarm prevails after reset,
exchange electronics
A111
electronics defect
RAM defect
Reset
if alarm prevails after reset,
exchange electronics
A113
electronics defect
RAM defect
Reset
if alarm prevails after reset,
exchange electronics
A114
electronics defect
E
2
PROM defect
Reset
if alarm prevails after reset,
exchange electronics
A115
electronics defect
general hardware problem
Reset
if alarm prevails after reset,
exchange electronics
A116
download error
repeat download
checksum of stored data not correct
restart download of data
A121
electronics defect
no factory calibration existant
E
2
PROM defective
contact service
W153
initialising - please wait
initialisation of electronics
wait some seconds; if warning
prevails, power off device and
power on again
A155
electronics defect
hardware problem
Reset
if alarm prevails after reset,
exchange electronics
A160
checksum error
general reset & new
calibr.required
device has been powered off before data
could be stored
emc problem
E
2
PROM defect
Reset
avoid emc problem;
if alarm prevails after reset,
exchange electronics
A164
electronics defect
hardware problem
Reset
if alarm prevails after reset,
exchange electronics
A171
electronics defect
hardware problem
Reset
if alarm prevails after reset,
exchange electronics
A231
sensor 1 defect
check connection
HF module or electronics defective
exchange electronics
A270
custody switch undefcheck
position
switch for custody transfer may be
defective
check position of custody
switchexchange electronics
#
mm - accuracy not ensured
inconsistency between phase and
amplitude evaluation
inconsistent microfactor
inconsistent index mapping
check basic calibrationcheck
mounting calibrationcheck echo
quality
> 10 dB history reset
A272
electronics defect
amplifier
inconsistency in amplification
exchange electronics
Содержание Micropilot S FMR531
Страница 4: ...Brief overview Micropilot S FMR531 with HART 4 20 mA 4 Endress Hauser ...
Страница 87: ...Micropilot S FMR531 with HART 4 20 mA Technical data Endress Hauser 87 ...
Страница 98: ...Micropilot S FMR531 with HART 4 20 mA Index 98 Endress Hauser ...
Страница 100: ...www endress com worldwide BA207F 00 en 04 09 71093754 CCS FM SGML 6 0 ProMoDo 71093754 ...