Mounting
Micropilot S FMR531 with HART/4...20 mA
20
E Hauser
3.4
Installation instructions
3.4.1
Mounting kit
In addition to the tool needed for flange mounting, you will require the following tool:
• 4 mm Allen wrench for turning the housing.
3.4.2
Installation in tank (free space)
Optimum mounting position
L00-FMR531xx-15-00-00-en-001
90°
90°
90°
90°
90°
90°
9
90°
90°
90°
±2°
0…2°
DN80…150
ANSI 3…6”
DN50
ANSI 2”
marker at instrument flange
Standard installation
• Observe installation instructions on Page 16.
• Marker is aligned towards tank wall.
• The marker is always exactly in the middle
between two bolt-holes in the flange.
• The device shall not be mounted in a slant
towards the tank wall.
• After mounting, the housing can be turned
350° in order to simplify access to the display
and the terminal compartment.
• In order to minimize temperature influences,
spring washers should be used in combination
with the plated flange of the FMR531.
• The rod antenna must extend below the
nozzle.
• Align rod antenna vertically
L00-FMR531xx-15-00-00-en-001
Antenna size
390 / 15
540 / 21
H [mm / inch]
< 100 / < 4
< 250 / < 10