Wiring
Micropilot S FMR531 with HART/4...20 mA
24
E Hauser
4
Wiring
4.1
Quick wiring guide
When grounding conductive screens, the corresponding directives EN 60079-14 and EN 1127-1
must be observed. Recommendation for safe grounding of conductive screens:
Wiring
L00-FMR53xxx-04-00-00-en-007
5
-
-
1 2 3 4
EN
DR
E
SS+
H
AUS
E
R
Ser
.-N
o
.
:
Order Code:
M
I
CROP
I
LOT S
U: 16
...
30
V
DC
TA
>
70
°
C:
4...
20 mA / 16
...
30
V
DC
Dat
.
/
I
nsp
.
:
D00676
-F
x
=
i
f mod
i
f
i
cat
i
on
see sep
. l
abe
l
0032
0560
Made
i
n
G
erman
y
79689
Mau
l
burg
P
N
max
.
TAntenne max
.
°C
Messbere
i
ch
Ansch
l
uss
w
erte u
.
Temp
.-
K
l
asse s
i
ehe/
Connect
i
on va
l
ues and temp
.-
c
l
ass
i
f
i
c
.
see
Measur
i
ng range
max
.
t
>
85°C
8
7
XXXXXXXXXXX
2
3
5
4
X X X X X X
1
PTB 00 AT
EX
II
1/2
G EE
x
i
a
II
C T6
...
T3
1 2 3 4 5
1
3
2
4
5
2
4
3
1
p
l
ant
ground
po
w
er:
2
4 V
DC
(16
…
30
V
)
;
from a
transm
i
tter
supp
ly
un
i
t
s
i
gna
l
:
2
4 V
DC
Connect up the M
i
crop
il
ot S as fo
ll
o
w
s:
Before unscre
w
hous
i
ng cover (2) at seperate connect
i
on room
turn off the po
w
er supp
ly!
I
nsert cab
l
e (3) through g
l
and (
4
)
.
Use screened, t
wi
sted 2
-wi
re or
4-wi
re cab
l
e
.
On
ly
ground screen
i
ng of the
li
ne (5) on sensor s
i
de
.
Ma
k
e connect
i
on (see p
i
n ass
i
gnment)
.
T
i
ghten cab
l
e g
l
and (
4
)
.
Scre
w
off hous
i
ng cover (2)
.
S
wi
tch on po
w
er supp
ly.
·
·
·
·
·
Before connect
i
on p
l
ease note the fo
ll
o
wi
ng:
The po
w
er supp
ly
must be
i
dent
i
ca
l
to the data on the
namep
l
ate (1)
.
S
wi
tch off po
w
er supp
ly
before connect
i
ng up the dev
i
ce
.
Connect
E
qu
i
potent
i
a
l
bond
i
ng to transm
i
tter ground
term
i
na
l
before connect
i
ng up the dev
i
ce
.
T
i
ghten the
l
oc
ki
ng scre
w
:
I
t forms the connect
i
on bet
w
een the antenna and the
hous
i
ng ground potent
i
a
l
·
·
·
·
·
The po
w
er supp
ly
be de
li
vered b
y
a transm
i
tter supp
ly
un
i
t
.
W
hen
y
ou use the measur
i
ng s
y
stem
i
n hazardous areas, ma
k
e sure
y
ou comp
ly wi
th
nat
i
ona
l
standards and the spec
i
f
i
cat
i
ons
i
n the safet
y i
nstruct
i
ons (
X
A
’
s)
.
Ma
k
e sure
y
ou use the spec
i
f
i
ed cab
l
e g
l
and
.
Caution!
"
A M
i
crop
il
ot S s
i
tuated
i
n a hazardous area
i
s connected as a
to a
s
i
tuated outs
i
de of the
hazardous area
. I
n th
i
s case,
i
t
i
s recommended that the screen be
connected d
i
rect
ly
to the M
i
crop
il
ot at the hous
i
ng
'
s earth,
w
hereb
y
the M
i
crop
il
ot S and the po
w
er supp
ly
un
i
t are connected to the same
potent
i
a
l
match
i
ng
li
ne (PML)
.
si
ng
l
e
d
e
vic
e
p
o
w
er
supply u
n
i
t an
d
tran
smi
tter
Содержание Micropilot S FMR531
Страница 4: ...Brief overview Micropilot S FMR531 with HART 4 20 mA 4 Endress Hauser ...
Страница 87: ...Micropilot S FMR531 with HART 4 20 mA Technical data Endress Hauser 87 ...
Страница 98: ...Micropilot S FMR531 with HART 4 20 mA Index 98 Endress Hauser ...
Страница 100: ...www endress com worldwide BA207F 00 en 04 09 71093754 CCS FM SGML 6 0 ProMoDo 71093754 ...