MEDEA Installation Manual
71
Electrical output
Positive present programmed
(positive safety)
No positive programmed
Stand-by
Active
Stand-by
Active
Table 33 - Electrical output stand-by state
4.8.2
Output position on MEDEA
Figure 74 - MEDEA output position
SR
power supply for external self-powered sirens
+V1
+13.8 V
⎓
-V1
earth
NC1
output 1 (relay), normally closed contact
NO1
output 1 (relay), normally open contact
C1
output 1 (relay), common contact
U2
output 2 (electrical)
4.8.3
PrIO configured as output
NOTE
: For the location of the PrIOs in the various devices see
The electrical outputs can be individually configured as:
•
“ s v p s " p , p v g V
⎓
.
•
“ p s v " p , w v s v g (p -free output).
Electrical outputs can be used to control relays (the relay coil must operate at 12 V
⎓
and require no more
current than the output can supply) or LEDs. Two relays in series can be used to control large loads.
The following diagrams are valid for an electrical output with positive reference and programmed as "no
positive".
Figure 75 - Relay connection diagrams to a PrIo output
V
V
Relay 1
RELAY
LO
AD
EL
ECTRICAL
O
UTPUT
Содержание MEDEA
Страница 95: ......