ER700-RF expansion module
1.10.1
Main elements
Figure 8 - ER700-RF expansion module elements
Ref.
Label
Description
A
+
Power positive (13.8 V
⎓
)
A
Data transmission/reception BUS A
B
Data transmission/reception BUS B
-
Power negative (Gnd)
B
TAMPER
Tamper input
C
+ A B -
BUS connection via cable to connectors
D
RUN
Wireless board communication LED
Flashing
= Receiving data from wireless board
ON
(30 seconds) = Local operation performed
E
Bus
BUS interface LEDs
Flashing
= Communication in progress
F
EXC
Expansion module tamper bypass
(jumper inserted = tamper bypassed)
G
PWR
BUS LED power (+13.8 V
⎓
)
ON
= Power present
H
+3V3
Logic LED power (+3.3 V
⎓
)
ON
= Power present
I
Wireless device LED
Slow flashing
= No device acquired
Normal flashing
= At least one device acquired
Fast flashing
= General fault