58
MEDEA Installation Manual
4.2.2
Power connection in metal box
Figure 50 - MEDEA power supply connection in metal box
IMPORTANT
Fasten the mains power cables to the cable tie holders with the cable ties provided.
Figure 51 - MEDEA PE connection in metal box
Connect the earth conductor (yellow-green) with one end without Faston, supplied, to the terminal block
of the box.
Note
: Power supply in CAT I 2500 V. Once installed, the power supply is subject to transient voltages
higher than those of the overvoltage category for which it was designed for this reason, an additional
transient voltage protection is required outside the device.
IMPORTANT
After connecting the conductors, remember to insert the plastic cover provided on
the power supply terminals.
IMPORTANT
The system must only be powered from the mains when all devices have been
correctly installed. For safety purposes, also close the casings of the control unit and any additional
power supply units before supplying power.
230 V~
Fuse
Cables
included
Earth cable with
Faston supplied
14.4 V
⎓
Cable tie
holder
Содержание MEDEA
Страница 95: ......