MEDEA Installation Manual
13
1.2.1
Control units
The control units consist of the combination of a motherboard (CPU), available in the MEDEA/32,
MEDEA/64 and MEDEA/160 versions, with a box, available in ABS and metal versions.
box
MEDEA/32 MEDEA/64 MEDEA/160
ABS (power supply 1.5 A, battery 7 Ah)
■
■
■
ABS (power supply 1.5 A, battery 9 Ah)
■
■
Metal (power supply 3.4 A, battery 18 Ah)
■
■
Table 4 - CPU-box matching
The CPUs have the following characteristics:
Features
MEDEA/32 MEDEA/64 MEDEA/160
Max. grade according to EN 50131
2
3
3
Inputs
6
6
6
PrIO
0
2
2
Tamper input (24H)
1
1
1
Relay output
1
1
1
O.C. output
1
1
1
SR output (siren power supply)
1
1
1
Bus RS485
1
2
2
USB A
-
1
1
USB B
1
1
1
Ethernet 10/100/1000
1
1
1
Manageable sectors (areas/departments)
8
16
32
Manageable scenarios
10
40
100
Stored events
1000
4000
4000
Max. number of Master users
1
1
1
Max. number of Technician users (installer)
1
1
1
Max. number of Technical Manager users
1
1
1
Max. number of users
50
150
200
Table 5 - CPU characteristics
PrIO is a connection terminal that can be configured as an input or output in programming.
1.2.2
Interfaces (optional modules)
The CPU is completed with optional interface boards. Up to 3 interfaces can be installed in the CPU chosen
from the following:
•
ILT700
: communication interface for connecting to traditional telephone lines (PSTN).
•
IT700-GSM
: communication interface for connecting to the GSM telephone network. The IT700-
GSM and IT700-4G interfaces are mutually alternative.
•
IT700-4G
: communication interface for connecting to the 4G telephone network. The IT700-GSM
and IT700-4G interfaces are mutually alternative.
•
IT700-WiFi
: interface for connecting to a wireless network or WiFi devices. With control panels with
metal box, the board can be operated using the UC700/ER-IT external control unit.
•
ER700-ZB
: interface for connection to ZigBee wireless devices. With control panels with metal box,
the board can be operated using the UC700/ER-IT external control unit.
The UC700-IT external control unit can be used if more than 3 interfaces need to be installed.