52
MEDEA Installation Manual
The keypad can be fixed directly to the wall with wall plugs or on top of a 3-module rectangular flush-
mounting box or on top of a 60 mm diameter round flush-mounting box, using the available holes. To
facilitate correct horizontal positioning, the keypad base is equipped with a level indicator.
Fixing on rectangular box
for flush-mounting, 3 positions
Fixing on 60 mm round flush-mounted box
For EN 50131 Grade 3 certification, the fixing hole for removal protection must always be used even if the
keypad is fixed on a flush-mounted box. This requirement is not compulsory for Grade 2 or lower
installations.
IMPORTANT
Before fixing the base, check its direction.
3.9.3
Closing the keypad
Re-apply the front of the keypad to the base, hooking in the sealing teeth.
3.10
DK700M-P / DK700M-P/B proximity reader installation
NOTE
: The two proximity readers differ only in the colour of the front panel (anthracite for DK700M-P and
white for DK700M-P/B).
The proximity reader is installed in modular flush-mounted or wall-mounted boxes, positioned in a dry
place.
The proximity reader is installed directly, or via an optional adapter, on the module holder frame. See
catalogue for correct adapter selection.
Figure 39 - DK700M-P / DK700M-P/B reader positioning in boxes
IMPORTANT
If two proximity readers are installed in the same box, leave at least the space of one
module between them (the space left free can still be occupied by another device).