MEDEA Installation Manual
65
4.5.4
DK700 tamper connection
Figure 67 - DK700 tamper connection
4.6
PrIO
PrIOs are programmable terminals, each independently configurable as an input or output.
4.8.3 PrIO configured as output
4.7
Connecting inputs
The type of input is determined by the way in which the detectors are physically connected. The type of
each input is then specified in the programming. In this way you can create a system that includes inputs
of different types.
The input specialisation is defined exclusively by programming.
4.7.1
Input types
Feature
Input type
NO
(normally
open)
NC
(normally
closed)
Single-
balanced
Double-
balanced
Triple-
balanced
Tandem
EN 50131 compliant
■
■
Circuit in stand-by
Open
Closed to
positive
Closed to
positive with
kΩ s s
1% tolerance
Closed to
positive with
kΩ s s s
kΩ
tolerance 1%
Closed to
positive with
kΩ kΩ
kΩ
resistors,
tolerance 1%
Closed to
positive with
kΩ kΩ
kΩ
resistors,
tolerance 1%
Circuit in alarm state
Closed to
positive
Open
Open
Open
Open
Open
Input alarm indication
■
■
■
■
■
■
Tamper signal (wire short
circuit)
■
■
■
■
Tamper warning (wire cut)
■
■
■
Fault/masking
■
Alarm 1 / Alarm 2
■
Stand-by voltage *
0 V
13.8 V
8 V
8 V
8 V
8 V
Voltage with input alarm *
13.8 V
0 V
0 V
5.6 V
7 V
Cut the yellow cable (PrIO1)
Example of connection
configured as a single-
balanced input
Содержание MEDEA
Страница 95: ......