![Elkron MEDEA Скачать руководство пользователя страница 89](http://html.mh-extra.com/html/elkron/medea/medea_installation-manual_2393467089.webp)
MEDEA Installation Manual
87
MEDEA/32
MEDEA/64
MEDEA/160
Keypads on BUS
8
16
16
BUS proximity readers
16
32
32
IT700-GSM (GSM/GPRS mobile phone interface)
■
■
■
IT700-4G (4G mobile phone interface)
■
■
■
ILT700 telephone line interface
■
■
■
IT700-WIFI interface
■
■
■
COMMUNICATIONS
Internet connectivity (TCP/IP)
■
■
■
SIA IP communication protocol (DC09)
■
■
■
SIA DTMF communication protocol (DC05)
■
■
■
Voice messages (TTS)
■
■
■
SMS text messages
■
■
■
Push alerts
■
■
■
Email alerts
■
■
■
Video clips and images
■
■
■
PROGRAMMING AND STORAGE
Integrated web server
■
■
■
boxes
ABS box with 1.5A power supply unit
■
■
■
Metal box with 3.4 A power supply unit
■
■
1. If the battery is not connected, there is no voltage at the ends of the connection cables (red and black
fasteners).
2. Only if the absence of the mains power supply is notified to an alarm receiving centre or other remote
centre.
3. +SR does not supply voltage in the event of a mains power failure.
4. A line fault must be recognised within 20 seconds (SP6) to ensure compliance with EN50136-2 in the
configuration of the LAN.
DP1 guaranteed with
:
Primary LAN and alternate ILT700 interface.
DP2 guaranteed with:
Primary LAN and alternative IT700-GSM interface, with periodic test not exceeding 30 min. enabled.
Содержание MEDEA
Страница 95: ......