![EDM Solution 862 Скачать руководство пользователя страница 54](http://html1.mh-extra.com/html/edm/solution-862/solution-862_installation-manual_2362278054.webp)
54
Solution 862
Installation Manual
Arming The System In STAY Mode 1
Arming the system in STAY Mode 1 is only used when the perimeter and unused areas of the
premises need to be armed to detect any would be intruder from entering the premises, at the
same time allowing you to move freely within an area which has been automatically isolated.
Programming zones to be automatically isolated in STAY Mode 1 can only be programmed by
the installer. Refer to Zone Options 2 on page 171 for further information on setting zones to
be automatically isolated in STAY Mode 1.
There are two methods for arming your system in STAY Mode 1. Method one is standard and
will always operate. Method two is optional and needs Option 2 in "LOCATION 429" to be
enabled on page 220.
Entry Guard Timer For STAY Mode
When arming the system in STAY Mode 1, an optional entry timer called Entry Guard Timer
For STAY Mode may be used to delay the sirens, strobe and bell outputs if a zone that has not
been automatically isolated has triggered into alarm condition. Entry Guard Timer For STAY
Mode is the delay time used for all zones except 24 hour zones when the system is armed in
STAY Mode 1 or STAY Mode 2.
If the Entry Guard Timer For STAY Mode has been programmed and a zone that has not been
automatically isolated has triggered, the codepad will beep twice a second until the Entry
Guard Timer For STAY Mode has expired or the system has been disarmed. If the alarm
condition has not been reset before Entry Guard Timer For STAY Mode expires, the strobe,
bell and siren outputs will activate into alarm.
Single button arming in STAY Mode 1 will report as user code number 16.
Method One
How To Arm The System In STAY Mode 1
1.
Enter your
followed by the
button.
Two beeps will be heard and the
STAY
indicator will illuminate. Exit time will now
commence.
Any zones that have been programmed to be automatically isolated in STAY Mode 1
will begin to flash until exit time expires. At the end of exit time, the
ZONE
indicators
will extinguish and the codepad will give one short beep.
+
ISSUE130
Electronics Design and Manufacturing Pty Limited
Содержание Solution 862
Страница 1: ...Solution 862 Installation Manual ISSUE 1 30...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 15: ...Introduction This section includes the following Introduction Features Quick Start Zone Defaults Zone Types...
Страница 43: ...Codepad Indicators This section includes the following CP5 Eight Zone LED Codepad CP5 Eight Zone LCD Codepad...
Страница 74: ...74 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 111: ...Remote System Operations Via Telephone This section includes the following Remote Arming Via The Telephone...
Страница 118: ...118 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 149: ...User Codes This section includes the following Installer Code User Codes User Code Priority...
Страница 154: ...154 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 188: ...188 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 212: ...212 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 228: ...228 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 237: ...Appendices This section includes the following Telephone Anti Jamming Test Reports Only When Armed...
Страница 240: ...240 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 245: ...Programming Sheets...
Страница 254: ...254 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 255: ...Index...
Страница 262: ......