Dialler Information
131
Primary Telephone Number For Receiver 1
LOCATION 000 - 015
0000000000000000
When the control panel needs to transmit a report, the control panel will dial this number in an
attempt to contact the monitoring station or pager etc. If the call is successful, the relevant
information will be transmitted and the dialler will return back to the stand-by mode.
If unsuccessful, the dialler will attempt two more times using the primary telephone number for
receiver 1, after which the secondary telephone number for receiver 1 will be called three
times. If the dialling sequence is still unsuccessful, the control panel will then attempt to
repeat this procedure dialling the primary telephone number and the secondary telephone
number for receiver 2 if programmed.
This procedure will be repeated only once again (i.e. Maximum of 12 call attempts per alarm)
after ten minutes if none of the first 6 attempts were successful if only the primary telephone
number and secondary telephone number for receiver 1 has been programmed.
If the primary telephone number and secondary telephone numbers for both receiver 1 and
receiver 2 have been programmed, a maximum of 24 call attempts per alarm will be made.
Contact your monitoring station or pager company for the relevant telephone numbers before
programming these locations.
When Receiver 1 has been set up for domestic reporting, telephone numbers
programmed into these locations will be ignored. Refer to Changing Domestic Phone
Numbers on page 78 when using the Installer Code function and Changing Domestic
Phone Numbers on page 94 when using the Master Code function.
Secondary Telephone Number For Receiver 1
LOCATION 016 - 031
0000000000000000
Refer to the Primary Telephone Number For Receiver 1 for programming information.
When Receiver 1 has been set up for domestic reporting, telephone numbers
programmed into these locations will be ignored. Refer to Changing Domestic Phone
Numbers on page 78 when using the Installer Code function and Changing Domestic
Phone Numbers on page 94 when using the Master Code function.
Electronics Design and Manufacturing Pty Limited
ISSUE130
Содержание Solution 862
Страница 1: ...Solution 862 Installation Manual ISSUE 1 30...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 15: ...Introduction This section includes the following Introduction Features Quick Start Zone Defaults Zone Types...
Страница 43: ...Codepad Indicators This section includes the following CP5 Eight Zone LED Codepad CP5 Eight Zone LCD Codepad...
Страница 74: ...74 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 111: ...Remote System Operations Via Telephone This section includes the following Remote Arming Via The Telephone...
Страница 118: ...118 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 149: ...User Codes This section includes the following Installer Code User Codes User Code Priority...
Страница 154: ...154 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 188: ...188 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 212: ...212 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 228: ...228 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 237: ...Appendices This section includes the following Telephone Anti Jamming Test Reports Only When Armed...
Страница 240: ...240 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 245: ...Programming Sheets...
Страница 254: ...254 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 255: ...Index...
Страница 262: ......