LOCATION 429
2
Option
Description
1
Codepad Display Extinguish After 60 Seconds
2
Single Button Arming Allowed (AWAY/STAY Mode 1 & 2)
4
Single Button Disarming Allowed (STAY Mode 1 & 2)
8
Alarm Memory Reset On Disarm
1
2
4
8
Table 130: Consumer Options 2
Codepad Display Extinguish After 60 Seconds
If this option has been selected, all indicators on the remote codepad display will extinguish if
a button is not pressed for 60 seconds. The indicators will illuminate when there is an alarm
(except a silent alarm), when a button is pressed on the codepad, when the AC mains fail
beeps, or if the entry timer has been activated.
Single Button Arming Allowed (AWAY Mode/STAY Mode 1 & 2)
If this option has been selected, the hold down functions for arming in AWAY Mode, STAY
Mode 1 and STAY Mode 2 will be functional. Refer to Hold Down Functions on page 107 for
more information.
Single Button Disarming Allowed (STAY Mode 1 & 2)
This option will only operate when Option 2 in this location has also been selected. This
option will allow hold down functions for disarming from STAY Mode 1 and STAY Mode 2.
Refer to Hold Down Functions on page 107 for more information.
Alarm Memory Reset On Disarm
This option allows the memory of alarm events to be cleared from the remote codepad when
the system has been disarmed. If this option has not been selected, the system will need to be
armed and disarmed again to clear alarm memory from the remote codepad.
ISSUE130
Electronics Design and Manufacturing Pty Limited
Содержание Solution 862
Страница 1: ...Solution 862 Installation Manual ISSUE 1 30...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 15: ...Introduction This section includes the following Introduction Features Quick Start Zone Defaults Zone Types...
Страница 43: ...Codepad Indicators This section includes the following CP5 Eight Zone LED Codepad CP5 Eight Zone LCD Codepad...
Страница 74: ...74 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 111: ...Remote System Operations Via Telephone This section includes the following Remote Arming Via The Telephone...
Страница 118: ...118 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 149: ...User Codes This section includes the following Installer Code User Codes User Code Priority...
Страница 154: ...154 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 188: ...188 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 212: ...212 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 228: ...228 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 237: ...Appendices This section includes the following Telephone Anti Jamming Test Reports Only When Armed...
Страница 240: ...240 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 245: ...Programming Sheets...
Страница 254: ...254 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 255: ...Index...
Страница 262: ......