Programming
37
Command 965 - Set Up Domestic Dialling Format
Command 965 has been included to allow the set up of the domestic dialling format a one step
operation. Refer to page 120 for more information on Domestic Dialling Format.
After you enter Installer's Programming Mode, enter command
965
followed by the
#
button. The command will automatically set Receiver 1 to domestic reporting and set the
following locations only for Receiver 2. No other locations will be changed when command
965 has been issued.
All domestic telephone numbers are stored in “LOCATION 466 – 513”. For more information
on programming domestic dialling, refer to Setting Up and Programming Domestic Reporting
on page 121 for more information.
Location
Description
Setting
LOCATION 032
Handshake Tone For Receiver 1
1
(Handshake Tone)
LOCATION 033
Transmission Format
4
(Domestic)
LOCATION 034 – 039
Subscriber ID Number
0, 0, 0, 0, 0,
1
(1 Beep)
LOCATION 332
Zone Status Reporting Options
2
(Receiver 2 Only)
LOCATION 333 – 334
Open/Close Reports
11, 12
(Open/Close Reports)
LOCATION 335
Open/Close Reporting Options
2
(Receiver 2 Only)
LOCATION 356 - 358
System Status – Access Denied
6, 7, 12
(Access Denied)
LOCATION 359
System Status Reporting Options
2
(Receiver 2 Only)
LOCATION 360 - 366
Test Reporting Time
0
,
0, 0, 0,
7, 1, 0
(Test Reports)
LOCATION 367
Test Reporting Dialler Options
1
(Receiver 1 Only)
Table 6: Command 965 Defaults
As you can see from the table above, the transmission format has automatically been set for
domestic dialling and the Subscriber ID Number has been set for one identification beep. All
reports except zone status reporting and system status reporting have been allocated to
Receiver 1 for domestic dialling.
This means that the zone status reports including zone bypass, zone trouble, sensor watch and
alarm restore codes as well as system status reports including fuse fail, AC fail, low battery and
access denied reports have been allocated to Receiver 2 and will not report unless Receiver 2
has also been set up to report.
Electronics Design and Manufacturing Pty Limited
ISSUE130
Содержание Solution 862
Страница 1: ...Solution 862 Installation Manual ISSUE 1 30...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 15: ...Introduction This section includes the following Introduction Features Quick Start Zone Defaults Zone Types...
Страница 43: ...Codepad Indicators This section includes the following CP5 Eight Zone LED Codepad CP5 Eight Zone LCD Codepad...
Страница 74: ...74 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 111: ...Remote System Operations Via Telephone This section includes the following Remote Arming Via The Telephone...
Страница 118: ...118 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 149: ...User Codes This section includes the following Installer Code User Codes User Code Priority...
Страница 154: ...154 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 188: ...188 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 212: ...212 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 228: ...228 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 237: ...Appendices This section includes the following Telephone Anti Jamming Test Reports Only When Armed...
Страница 240: ...240 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 245: ...Programming Sheets...
Страница 254: ...254 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 255: ...Index...
Страница 262: ......