![EDM Solution 862 Скачать руководство пользователя страница 121](http://html1.mh-extra.com/html/edm/solution-862/solution-862_installation-manual_2362278121.webp)
Domestic Dialling
121
Setting Up and Programming Domestic Reporting
Programming the control panel for domestic reporting has been made extremely simple by the
use of the Installer's Programming Command 965. Refer to Command 965 - Set Up Domestic
Dialling Format on page 37 for more information.
How To Set Up The Control Panel For Domestic Dialling
1.
Enter Installer's Programming Mode (EG:
1234
followed by the
button).
Two beeps will be heard and the
STAY
and
AWAY
indicators will begin to flash.
2.
Enter Command
965
followed by the
button.
Two beeps will be heard. The control panel has now been set up for Domestic Dialling
Format. Refer to Command 965 - Set Up Domestic Dialling Format on page 37 for
more information.
3.
Exit Installer's Programming Mode by entering Command
960
followed by the
button. Two beeps will be heard and the
STAY
and
AWAY
indicators will
extinguish. The system will now return to the disarmed state.
4.
Enter your
followed by
2
and the
button.
Three beeps will be heard and the
STAY
and
AWAY
indicators will begin to flash.
If there are telephone numbers programmed, they will be displayed one digit at a time
via the codepad indicators.
If there are no telephone numbers programmed, a further two beeps will be heard after
entering this mode. These two beeps are normally heard after the last digit of the last
phone number has been displayed.
5.
Enter all the digits for
, one digit at a time. You will notice as each digit is
entered, the corresponding codepad indicators will illuminate.
6.
If there is more than one telephone number, press the
button followed by the
4
button after the last digit of the telephone number. This will insert a break between the
first telephone number and the second telephone number. If there is only one telephone
number, press the
button to exit this mode.
7.
Enter all the digits for
, one digit at a time. You will notice as each digit is
entered, the corresponding codepad indicators will illuminate.
8.
After the last digit of the second telephone number, press the
button to exit this
mode unless a third telephone number is required. If there is a third telephone number
to be programmed, press the
button followed by the
4
button to insert a break
between the second telephone number and the third telephone.
+
2
+
+
+
+
4
+
+
Electronics Design and Manufacturing Pty Limited
ISSUE130
Содержание Solution 862
Страница 1: ...Solution 862 Installation Manual ISSUE 1 30...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 15: ...Introduction This section includes the following Introduction Features Quick Start Zone Defaults Zone Types...
Страница 43: ...Codepad Indicators This section includes the following CP5 Eight Zone LED Codepad CP5 Eight Zone LCD Codepad...
Страница 74: ...74 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 111: ...Remote System Operations Via Telephone This section includes the following Remote Arming Via The Telephone...
Страница 118: ...118 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 149: ...User Codes This section includes the following Installer Code User Codes User Code Priority...
Страница 154: ...154 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 188: ...188 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 212: ...212 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 228: ...228 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 237: ...Appendices This section includes the following Telephone Anti Jamming Test Reports Only When Armed...
Страница 240: ...240 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 245: ...Programming Sheets...
Страница 254: ...254 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 255: ...Index...
Страница 262: ......