![EDM Solution 862 Скачать руководство пользователя страница 171](http://html1.mh-extra.com/html/edm/solution-862/solution-862_installation-manual_2362278171.webp)
Zone Information
171
Zone Options 2
When programming this location, you will notice that there are four options per location. You
may select one, two, three or all four of these options, however, only one number needs to be
programmed. This number is calculated by adding the option bit numbers together. Program a
seven (7) if you require options 1, 2 and 4 simultaneously (i.e. 1 + 2 + 4 = 7).
1
Isolate In STAY Mode 1
2
Zone Isolation Allowed
4
Forced Arming Allowed
8
Zone Restore Report
1
2
4
8
Option
Description
Table 76: Zone Options 2
Isolate In STAY Mode 1
If this option has been selected, it will allow the zone to be automatically isolated when the
system has been armed in STAY Mode 1.
If this option is not selected, when the system has been armed in STAY Mode 1, the zone will
activate an alarm when triggered as it normally would in AWAY Mode.
Refer to Entry Guard Timer For STAY Mode on page 205 if you wish to program a global
entry time for ALL zones except for 24 hour zone types when armed in STAY Mode 1 (i.e.
The entry guard timer will override the delay time programmed for a delay zone). If the entry
guard timer has been programmed as "0" each zone will act as per its programmed zone type.
Refer to Arming The System In STAY Mode 1 on page 54 for more information.
Zone Isolation Allowed
If this option has been selected, it will allow the system operator to isolate the zone before
arming the system. If this option is not selected, the zone can not be manually isolated. When
a zone has been manually isolated, a zone bypass report (Contact ID Event Code 570) will be
sent. Refer to Isolating Zones on page 60 for more information.
When isolating 24 hour zone types, the 24 hour zone will automatically send a zone bypass
report at the time the zone is selected to be isolated. All non 24 hour zone types will only send
a bypass report at the time the system is armed.
If you require the system not to report zone bypass reports, program “LOCATION 325 - 326”
on page 176 as zeros.
Forced Arming Allowed
If this option has been selected, it will allow the system to be armed with the zone unsealed. If
this option is not selected, the system will not allow the user code holder to arm the system
until the zone in question has been sealed or manually isolated. Refer to Isolating Zones on
page 60 for more information.
Zone Restore Report
If this option bit has been selected, the zone will send restore reports as soon as the zone has
restored. If this option bit has not been selected, the zone will not send restore reports after the
zone has restored.
If a non 24 hour zone has not restored at the time the system is disarmed, the system will
automatically send a zone restore report for that zone. All 24 hour zone types will only send a
zone restore report at the time the zone has restored.
Electronics Design and Manufacturing Pty Limited
ISSUE130
Содержание Solution 862
Страница 1: ...Solution 862 Installation Manual ISSUE 1 30...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 15: ...Introduction This section includes the following Introduction Features Quick Start Zone Defaults Zone Types...
Страница 43: ...Codepad Indicators This section includes the following CP5 Eight Zone LED Codepad CP5 Eight Zone LCD Codepad...
Страница 74: ...74 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 111: ...Remote System Operations Via Telephone This section includes the following Remote Arming Via The Telephone...
Страница 118: ...118 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 149: ...User Codes This section includes the following Installer Code User Codes User Code Priority...
Страница 154: ...154 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 188: ...188 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 212: ...212 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 228: ...228 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 237: ...Appendices This section includes the following Telephone Anti Jamming Test Reports Only When Armed...
Страница 240: ...240 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 245: ...Programming Sheets...
Страница 254: ...254 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 255: ...Index...
Страница 262: ......