![EDM Solution 862 Скачать руководство пользователя страница 215](http://html1.mh-extra.com/html/edm/solution-862/solution-862_installation-manual_2362278215.webp)
System and Consumer Options
215
System Options 1
LOCATION 424
1
Option
Description
1
EDM Smart Lockout Allowed
2
Horn Speaker Monitor
4
Strobe Indications For Radio Arm/Disarm
8
Horn Speaker Beeps For Radio Arm/Disarm
Table 123: System Options 1
EDM Smart Lockout Allowed
1
This feature allows the control panel to remove any zones that are programmed for lockout
dialler from the lockout list while the sirens are running. This feature allows a monitoring
station to receive zone alarm reports from previously locked out zones during siren time. Refer
to Zone Options 1 on page 167 for information on programming zones for lockout dialler and
lockout siren.
Refer to Swinger Shutdown Count For Dialler on page 174 to program the number of times the
zone can report before being locked out.
Horn Speaker Monitor
2
If this option has been selected, the control panel will detect when the horn speaker has been
disconnected from the speaker terminals. The
FAULT
indicator will illuminate when the horn
speaker has been disconnected and will extinguish when the horn speaker has been
reconnected. If an output is required to operate when the horn speaker has been disconnected,
refer to Output Event Type – Horn Speaker Monitor Fail on page 194 for more information.
Strobe Indications For Radio Arm/Disarm
4
This option will allow the strobe to indicate when the system is armed and disarmed when
remotely operating the system via the Solution Wireless On/Off Interface (WE800).
No Of Seconds
System Status
3 Seconds
System Disarmed
6 Seconds
System Armed In AWAY Mode
6 Seconds
System Armed In STAY Mode 1
Table 124: Strobe Indications For Remote Operations
Horn Speaker Beeps For Radio Arm/Disarm
8
This option will allow the horn speaker to indicate when the system is armed and disarmed
when remotely operating the system via the Solution Wireless On/Off Interface (WE800).
No Of Beeps
System Status
1
System Disarmed
2
System Armed In AWAY Mode
1 Two Tone
Beep
System Armed In STAY Mode 1
Table 125: Horn Speaker Beeps For Remote Operations
Electronics Design and Manufacturing Pty Limited
ISSUE130
Содержание Solution 862
Страница 1: ...Solution 862 Installation Manual ISSUE 1 30...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 15: ...Introduction This section includes the following Introduction Features Quick Start Zone Defaults Zone Types...
Страница 43: ...Codepad Indicators This section includes the following CP5 Eight Zone LED Codepad CP5 Eight Zone LCD Codepad...
Страница 74: ...74 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 111: ...Remote System Operations Via Telephone This section includes the following Remote Arming Via The Telephone...
Страница 118: ...118 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 149: ...User Codes This section includes the following Installer Code User Codes User Code Priority...
Страница 154: ...154 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 188: ...188 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 212: ...212 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 228: ...228 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 237: ...Appendices This section includes the following Telephone Anti Jamming Test Reports Only When Armed...
Страница 240: ...240 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 245: ...Programming Sheets...
Страница 254: ...254 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 255: ...Index...
Страница 262: ......