Dialler Information
141
Telephone Line Fault Options
LOCATION 176
0
When programming this location, you will notice that there are four options per location. If
you require options 1, 2, 4 or all of these options, only one number needs to be programmed.
This number is calculated by adding the option bit numbers together. Program a 7 if you
require options 1, 2 and 4 simultaneously (i.e. 1 + 2 + 4 = 7).
Option
Description
1
Display FAULT Indicator When Telephone Line Fails
2
Sound Alarm When System Is Armed
4
Sound Alarm When System Is Disarmed
8
Reserved
Table 61: Telephone Line Fault Options
The control panel has the ability to monitor the telephone line. If the telephone line has been
cut or disconnected for more than forty seconds, the control panel will recognise this and the
FAULT
indicator will illuminate on the codepad. The
FAULT
indicator will extinguish once the
telephone line has been restored for more than forty seconds.
Option 2 and 4 will not operate unless option 1 has been enabled.
1
2
4
8
Display FAULT Indicator When Telephone Line Fails
The
FAULT
indicator will flash and the codepad buzzer will beep once every minute if the
control panel detects that the telephone line has been disconnected. Refer to Fault Descriptions
on page 64 for more information.
Sound Alarm When System Is Armed
Option 1 in this location will also need to be selected for this option to operate. If the control
panel detects that the telephone line has been disconnected when the system is armed in
AWAY Mode, STAY Mode 1 or STAY Mode 2, the horn speaker, bell and strobe outputs will
operate.
Sound Alarm When System Is Disarmed
Option 1 in this location will also need to be selected for this option to operate. If the control
panel detects that the telephone line has been disconnected when the system is disarmed, the
horn speaker, bell and strobe outputs will operate.
Reserved
If Options 1, 2 and 4 have been added together, the horn speaker, bell, strobe and
EDMSAT outputs will operate when the system is armed or disarmed.
Electronics Design and Manufacturing Pty Limited
ISSUE130
Содержание Solution 862
Страница 1: ...Solution 862 Installation Manual ISSUE 1 30...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 15: ...Introduction This section includes the following Introduction Features Quick Start Zone Defaults Zone Types...
Страница 43: ...Codepad Indicators This section includes the following CP5 Eight Zone LED Codepad CP5 Eight Zone LCD Codepad...
Страница 74: ...74 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 111: ...Remote System Operations Via Telephone This section includes the following Remote Arming Via The Telephone...
Страница 118: ...118 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 149: ...User Codes This section includes the following Installer Code User Codes User Code Priority...
Страница 154: ...154 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 188: ...188 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 212: ...212 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 228: ...228 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 237: ...Appendices This section includes the following Telephone Anti Jamming Test Reports Only When Armed...
Страница 240: ...240 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 245: ...Programming Sheets...
Страница 254: ...254 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 255: ...Index...
Страница 262: ......