179
Open/Close Reports
LOCATION 333 - 334
Location
Description
333
Opening Report
334
Closing Report
Table 84: Open/Close Reporting Locations
An "Opening" report (Contact ID Event Code 401) will be transmitted to the base station
receiver when the system has been disarmed from AWAY Mode. A "Closing" report (Contact
ID Event Code 401) is transmitted at the end of exit time when the system has been armed in
AWAY Mode.
If an expanded format has been selected, this code will be used as the expansion code and the
user number that armed or disarmed the system will follow in the same transmission.
Refer to Option 2 in "LOCATION 178" on page 146 for programming "Open/Close" reports in
STAY Mode. To program "Open/Close" reports only after a previous alarm, refer to Option 1
in "LOCATION 178" on page 146.
If you do not require "Open/Close" reports, program "LOCATION 333 - 334" with zero.
Open/Close Reporting Options
LOCATION 335
Option
Description
0
No Report Required
1
Receiver 1
2
Receiver 2
4
Receiver 1 and Receiver 2
8
Receiver 2 Only When Receiver 1 Fails
Table 85: Open/Close Reporting Options Location
This location is factory default to report only to receiver 1. You can select whether the
open/close reports will report on receiver 1, receiver 2, both receiver 1 and receiver 2, receiver
2 only when receiver 1 fails or no reporting at all.
Electronics Design and Manufacturing Pty Limited
ISSUE130
1
Содержание Solution 862
Страница 1: ...Solution 862 Installation Manual ISSUE 1 30...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 15: ...Introduction This section includes the following Introduction Features Quick Start Zone Defaults Zone Types...
Страница 43: ...Codepad Indicators This section includes the following CP5 Eight Zone LED Codepad CP5 Eight Zone LCD Codepad...
Страница 74: ...74 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 111: ...Remote System Operations Via Telephone This section includes the following Remote Arming Via The Telephone...
Страница 118: ...118 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 149: ...User Codes This section includes the following Installer Code User Codes User Code Priority...
Страница 154: ...154 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 188: ...188 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 212: ...212 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 228: ...228 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 237: ...Appendices This section includes the following Telephone Anti Jamming Test Reports Only When Armed...
Страница 240: ...240 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 245: ...Programming Sheets...
Страница 254: ...254 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Страница 255: ...Index...
Страница 262: ......