8-57
8.3
Configuring COM Ports
There are three available COM ports on the Topside Interface Box to provide the necessary information
to the 6205s2. This information includes position (latitude/longitude), heading, attitude (roll, pitch, and
heave), and time. This appendix explains how to configure the three COM ports depending on the type of
sensors used.
NOTE:
Most COM port configurations should be completed via the
Discover Bathymetric Software.
8.3.1
One Sensor
One sensor, such as the Applanix PosMV, may be used to supply position (latitude/longitude), heading,
attitude, and a time source. For this type of configuration, only COM1 will be utilized.
To configure the COM ports for one sensor:
1.
Turn on Topside PC and connect the 6205s2 via the deck cable to the 6205s2 Topside Interface
Box.
2.
Turn on the 6205s2 Sonar Head and run the Remote Desktop Application, named Sonar. The main
should appear.
Figure 8-11: Sonar Remote Desktop Application, Main Screen
Here, the user will see the Sonar Application running (designated by the blue arrow). Sonar.exe is
the firmware that controls the system.
3.
Click on the 'X' at the top right to close the firmware.
4.
Double click on the Shortcut to EdgeTech icon and open the SSSonarBathy folder, then the Sonar
folder.
5.
Look for the SonarSerial.ini file, as shown in
, and open it using WordPad or Notepad,
Содержание 6205S2
Страница 32: ...2 32 Figure 2 2 6205s2 Sonar Head with Adaptor Flange ICD...
Страница 33: ...2 33 Figure 2 3 6205s2 Side Scan Transducer...
Страница 34: ...2 34 Figure 2 4 6205s2 Side Scan Transducer Details...
Страница 35: ...2 35 Figure 2 5 6205s2 Deck Cable Wiring Diagram...
Страница 36: ...2 36 Figure 2 6 6205s2 GNSS INS Deck Cable Wiring Diagram...
Страница 37: ...2 37 2 6 2 6205s2 Topside Figure 2 7 6205s2 Rack Mounted Topside...
Страница 38: ...2 38 Figure 2 8 6205s2 Rack Mount in Case...
Страница 41: ...3 41 3 1 2 2 Sonar Processor Endcap and Pinout Drawings Figure 3 5 6205S2 Forward End Cap...
Страница 42: ...3 42 6205s2 BATHYMETRIC AND SIDE SCAN SONAR 0025262_REV_A Figure 3 6 6205s2 Aft End Cap...
Страница 46: ...3 46 Figure 3 11 6205s2 Acoustic Center Location X Y Z and Bolt Pattern...
Страница 47: ...3 47 Figure 3 12 6205s2 with Adaptor Flange Acoustic Center Location X Y Z and Bolt Pattern...
Страница 91: ...8 67 Figure 8 22 Checking all COM Ports...