Topside Provided Isolation
The two most common sources of electrical noise (interference) are power supplies and poor grounding
on survey vessels. Edgetech’s proprietary signal conditioning and isolation board is shipped with every
topside to protect against the noise fluctuations on the ground line of the subsea electronics. This board
isolates the sensitive subsea electronics from potentially noisy grounds provided by the trigger and serial
port inputs. Noise can often be identified as repeating patterns at the edge of the usable range of data
within Discover’s waterfall display.
Figure 4-6: Chevron Pattern Noise in a Cropped Portion of Discover Bathymetric
Chevron Pattern Noise
Chevron Pattern Noise
Содержание 6205S2
Страница 32: ...2 32 Figure 2 2 6205s2 Sonar Head with Adaptor Flange ICD...
Страница 33: ...2 33 Figure 2 3 6205s2 Side Scan Transducer...
Страница 34: ...2 34 Figure 2 4 6205s2 Side Scan Transducer Details...
Страница 35: ...2 35 Figure 2 5 6205s2 Deck Cable Wiring Diagram...
Страница 36: ...2 36 Figure 2 6 6205s2 GNSS INS Deck Cable Wiring Diagram...
Страница 37: ...2 37 2 6 2 6205s2 Topside Figure 2 7 6205s2 Rack Mounted Topside...
Страница 38: ...2 38 Figure 2 8 6205s2 Rack Mount in Case...
Страница 41: ...3 41 3 1 2 2 Sonar Processor Endcap and Pinout Drawings Figure 3 5 6205S2 Forward End Cap...
Страница 42: ...3 42 6205s2 BATHYMETRIC AND SIDE SCAN SONAR 0025262_REV_A Figure 3 6 6205s2 Aft End Cap...
Страница 46: ...3 46 Figure 3 11 6205s2 Acoustic Center Location X Y Z and Bolt Pattern...
Страница 47: ...3 47 Figure 3 12 6205s2 with Adaptor Flange Acoustic Center Location X Y Z and Bolt Pattern...
Страница 91: ...8 67 Figure 8 22 Checking all COM Ports...