8-64
6205s2 BATHYMETRIC AND SIDE SCAN SONAR
0025262_REV_A
Figure 8-20: Checking Sensors’ Usages
12.
When satisfied with incoming data, press
OK
in the ‘System Status’ window, as shown in
FIGURE
8-
20
.
13.
Finally, close the Sonar - 192.9.0.101 - Remote Desktop Connection window.
NOTE:
If this window is left open during data acquisition, you may
experience a very slow computer because the Remote Desktop uses a
large amount of the link capacity to stay open. When finished with the
configurations, it is wise to close the Remote Desktop.
8.3.3
Three Sensors
Three sensors, such as a gyro (heading), a GNSS (position and time source), and a Motion Reference Unit
(roll, pitch, and heave), may be used to supply the necessary information. For this type of configuration,
all available COM ports will be used.
The following steps should be carried out to configure the COM ports for the three sensors.
Содержание 6205S2
Страница 32: ...2 32 Figure 2 2 6205s2 Sonar Head with Adaptor Flange ICD...
Страница 33: ...2 33 Figure 2 3 6205s2 Side Scan Transducer...
Страница 34: ...2 34 Figure 2 4 6205s2 Side Scan Transducer Details...
Страница 35: ...2 35 Figure 2 5 6205s2 Deck Cable Wiring Diagram...
Страница 36: ...2 36 Figure 2 6 6205s2 GNSS INS Deck Cable Wiring Diagram...
Страница 37: ...2 37 2 6 2 6205s2 Topside Figure 2 7 6205s2 Rack Mounted Topside...
Страница 38: ...2 38 Figure 2 8 6205s2 Rack Mount in Case...
Страница 41: ...3 41 3 1 2 2 Sonar Processor Endcap and Pinout Drawings Figure 3 5 6205S2 Forward End Cap...
Страница 42: ...3 42 6205s2 BATHYMETRIC AND SIDE SCAN SONAR 0025262_REV_A Figure 3 6 6205s2 Aft End Cap...
Страница 46: ...3 46 Figure 3 11 6205s2 Acoustic Center Location X Y Z and Bolt Pattern...
Страница 47: ...3 47 Figure 3 12 6205s2 with Adaptor Flange Acoustic Center Location X Y Z and Bolt Pattern...
Страница 91: ...8 67 Figure 8 22 Checking all COM Ports...