ecoGEO C Installation and User Manual (Version 1.0)
page 70
8.4
Wiring diagrams ecoGEO C1
ecoGEO C1 power diagram
230 V ~
95
85
86
87
96
97
RA
92
82
230V ~
83
84
93
94
EXTENSION FILTER
EF_2
EF_1
INVERTER
EF_4
EF_3
M
3 ~
I_1
I_2
I_4
I_3
I_5
COMPRESOR
80
91
81
G0
G
88
89
PRA
PRB
44
43
42
41
ALARM
BCl
BCap
69
68
71
72
74
75
73
70
90
T_1
T_2
230V ~
VACS
45
47
46
48
BIT
2
36
35
37
NO11
NO12
NO10
NO9
NO8
NC7
NO7
NO6
NO4
NO3
NO2
NO1
C1
NO5
Micro
-controlador
ecoGEO C1 POWER CONNECTIONS
Nomenclature
Description
G
Micro-controller power supply (Phase)
G0
Micro-controller power supply (Neutral)
EF_X
Connection X EMI extension filter
I_X
Connection X Inverter
Digital outputs (to relay)
VACS_X
DHW Valve, Wire X
BIT2
Circulating pump (2
nd
BCap
zone)
Brine circuit pump
BCl
Heating circuit pump
ALARM
Alarm
RA
Electric heater (legionella protection)
Содержание ecoGEO C
Страница 1: ...ecoGEO C Installation and user manual...