Application
•
DHW and heating in houses, small apartment blocks, offices or shops with underfloor heating systems,
fan coil units, thermo-convector or low-temperature radiators.
Operation
The heat pump pumps hot water directly to the heating system adapting to your needs. The outlet
temperature is adjusted to the type of installation and is optimized with regards to indoor and outdoor
temperatures. The flow rate is adjusted to maintain a constant working temperature difference (5°C by
default).
When there is a demand for DHW, the heat pump stops the production of heating and sends hot water to the
coil in the hot water tank. The temperature and flow rate are controlled to minimize heating time (maximum
accumulation temp 50-55°C). Once a week, the electric heater located in the hot water tank is activated to
raise the temperature to 70°C to prevent possible outbreaks of legionella in the tank.
Additional control elements
Besides the heat pump control equipment you must install the following components.
•
An indoor terminal that registers the temperature, one or more relay type indoor thermostats (see
section 5.7).
•
An outdoor temperature probe (see section 5.7).
Configuration
1.
Enter the SERVICE MENU
([Prg]
+
[Esc])
-> INSTALLER CONF. (Enter service password PW1) ->
OPERATING SCHEME -> 1 ZONE.