ecoGEO C Installation and User Manual (Version 1.0)
page 33
MENU 2.4.4.4. Inverter Contactor
For all ecoGEO heat pump models. The status (On / Off) the inverter contactor can be defined.
MENU 2.4.4.5. Elect. Heater cont.
For all ecoGEO heat pump models and all operating schemes. The status (On / Off) of the
electric heater (legionella protection) contactor can be defined.
MENU 2.4.4.6. Zone valve and pump
For all ecoGEO heat pump models in installations with Scheme 4. The status (On/Off) of the 2
nd
zone pump and the 2
nd
zone valve con be defined.
MENU 2.4.4.7. Alarm system
For all ecoGEO heat pump models. The status (On / Off) of the alarm system signal can be
defined.
MENU 2.4.4.8. DHW valve
For all ecoGEO C1 and ecoGEO C2 heat pump models. The status (On/Off) of the DHW valve
can be defined.
MENU 2.4.4.9. DHW pump
For the ecoGEO C3 heat pump model. The status (On / Off) of the DHW production system,
which includes the activation of the circulation pump and the DHW solenoid valve can be
defined.
MENU 2.4.4.10. Free cooling valve
For the ecoGEO C2 heat pump model. The status (On / Off) of the free cooling system valves
can be defined.
MENU 2.4.4.11. Reversing valve
For the ecoGEO C3 heat pump model. The status (On/Off) of the reversing cycle valve can be
defined.
MENU 2.4.5 Probe conf.
Shows the type of each of the temperature probes in the installation, the measured value for each and
allows the correction of its values. Correction is recommended only when long probe cable lengths are
used.
MENU 2.4.5.1 Brine outlet Temp.
Displays the type and value measured by the brine outlet temperature probe with an offset for
correcting the value.
MENU 2.4.5.2 Brine inlet Temp.
Displays the type and value measured by the brine inlet temperature probe with an offset for
correcting the value.