ecoGEO C Installation and User Manual (Version 1.0)
page 57
11.
Only if indoor th-Tune terminals are installed go to TH-TUNE and enable the th-Tune option. Set values
of 1 and 2 for the indoor terminal address of the main and secondary zones, respectively. This second
zone only exists if you have selected Scheme 4. We recommend not changing the default values that
appear on the screen in "BMS SETTINGS" (
Figure 4.7
). Press
[Esc]
to return to menu INSTALLER CONF.
12.
Only if conventional relay type thermostats are installed Go to MANUAL CONF. In the digital inputs
display, enable the THERMOSTAT IMPUT DI1 and choose the operating logic, NO or NC (normally open
or normally closed). If you choose the NC option, the input entered in contacts 38 and 39 (see section
8.3) so the pump is activated must be an open circuit. If the NO option is chosen, the input required for
the activation of the pump is a closed circuit. For ecoGEO C3 models, the same thermostat can be used
to control active heating and cooling. To do so, when choosing, you must take into account the heat
pump logic to produce heating or cooling, respectively.
13.
Go to PROBE CONF. In this menu, you can make corrections to the values measured by the
temperature probes. These are factory calibrated and we only recommend correcting the value of the
outdoor probe if using a long cable. Press
[Esc]
to return to menu INSTALLER CONF.
14.
We recommend changing the password once the computer settings are complete to prevent users
accessing those menus for use by the installer. Once modified, write it down and keep it handy for
future maintenance work. Select the CHANGE PASSWORD and change it.
Parameter
System
Recommended
Value
Comments
Indoor design temperature
-
(21-23) ºC
Regulation of Thermal
Installations in Buildings
Outdoor design temperature
-
1
-
UNE 1000012001
Heating outlet design
temperature
Low temperature
radiators
50 ºC.
Technical Committee CEN /
TC 228
Fancoils / Convectors
45 ºC.
Underfloor heating
35 ºC.
Heating curve gradient
-
1
-
1
Table 6.2.
Recommended values for the parameters of climate control.
Minimum environmental temperature for operating the installation. It is based on the place where the installation is located.
6.6
Final inspection and commissioning of the installation
NOTE
The initial start-up should only be done after verifying that the heating/cooling, brine and DHW
circuits have been filled and purged properly. Damage may cause equipment malfunction.
Note that if during start up any alarm is triggered, it may be due to faulty circuit purging.
ecoGEO heat pumps have a program for drying the floors when underfloor heating is installed (see
section ).