Eaton RF System 2.42

Manual

Содержание RF System 2.42

Страница 1: ...Eaton RF System 2 42 Manual...

Страница 2: ...Redo 13 Connection Mode 14 Selection mode 15 Define password 15 Load password 16 Delete password 16 Options 18 Insert menu 18 Commands of the Insert menu 19 Background grafic 20 Project Note 21 Group...

Страница 3: ...e input 77 Gateway 79 Home Manager RF 80 Analog actuator 83 Room Manager 83 Overview Room Manager 87 Heating and cooling with the Room Manager 91 Outputs and the Room Manager 92 Ventilation control wi...

Страница 4: ...lse input 139 Remote control with display 139 Overview Remote control with display 140 Remote control with display Functions 141 Remote control with display Timer 141 Remote control with display Gener...

Страница 5: ...08 Configuration Example of the Room Controller 210 7 Things to know 210 How to correctly update SHC from 1 x to 2 x 211 Icons and their meaning 214 How does the routing work 215 What is a group funct...

Страница 6: ...ncerning Devices and Zones as well as administration of Interfaces If you already have an existing SHC Configuration where these settings have been done in the Web Admin Console please read the topic...

Страница 7: ...ick Software USB V2 05 RF V2 08 the actual file and Changelog can be found in the Subfolder Device Software in the Eaton RF System main folder Contains the Ethernet CI Software LAN V1 04 RF V2 00 the...

Страница 8: ...ections is now realized for all devices Energy measurement sensor RF Radiator thermostat etc missing before It is no longer possible to use datapoints of intelligent devices as outputs in the connecti...

Страница 9: ...y in the subfolder Device software Room Manager Virtual Room controllers used for Heating actuators will now be inserted with the right mode Send temperature value How to start After starting the prog...

Страница 10: ...give them a name Additional setting possibilities See System password See Connection Mode See Selection mode See Load See Symbols and their meaning See Configuration Examples Commands of the File Menu...

Страница 11: ...he Command Save File Menu Use this command to save the active project under its current name and directory When saving a project for the first time use the Dialog Field Save as so you can type a name...

Страница 12: ...devices will also be displayed here By left clicking on one of the column headers the list will be alphabetically sorted by this category Individual elements within the list can be moved by using the...

Страница 13: ...Load password Loads the defined password in the devices Delete password Deletes the password in the devices and resets the system password Options Opens the window with the setting options Undo When...

Страница 14: ...e Toolbar Selection mode The main purpose of selection mode is to include new devices in an existing project but it can also be used to recalculate the reception quality of individual selected devices...

Страница 15: ...nt to allocate the selected devices Copy selected devices Copies the selected devices to the clipboard as virtual devices Remove selected devices Removes the selected devices from the project Load cha...

Страница 16: ...usly or which did not yet have a password will not be included The password for the project will also be reset to No password The password can also be deleted individually from one device via Device d...

Страница 17: ...ity connections This raises the number of routing paths but guaranties a safer transmission In the professional version you can determine the behaviour when drawing connections 1 Calculate immediately...

Страница 18: ...Configuration Stick you can set the Transmit and Receive power of the Gateway Default 90 In some situations it may be of advantage to work with a reduced range in special when you want to scan only s...

Страница 19: ...eft to the user s discretion The function Insert background grafic can be executed in several ways 1 Menu Insert Background grafic 2 Right click on blank MRF workspace Insert background grafic 3 Tool...

Страница 20: ...device groups in the project or general information on the configuration The function Insert project note can be executed in several ways 1 Menu Insert Project note 2 Right click on blank MRF workspac...

Страница 21: ...nction Insert group frames can be executed in several ways 1 Menu Insert Group frames 2 Right click on blank MRF workspace Create group frames 3 Tool bar As with the selection mode the function remain...

Страница 22: ...nu options View Group frames or by Right clicking in the workspace Display group frames Insert MRF project This function offers the option of inserting devices incl all settings from an already existi...

Страница 23: ...er the function has been executed the insertion options will be displayed Here you can select whether the original project or a configuration template for the selected project is to be inserted and wh...

Страница 24: ...24 Eaton RF System Help 2015 Eaton Electrical Group Insert configuration template All devices in the selected project will be inserted as virtual devices...

Страница 25: ...ctions the configuration of a virtual device can be transferred to a particular real device The function Insert virtual devices can be executed in several ways 1 Menu Insert Virtual devices 2 Right cl...

Страница 26: ...ices to a project simply by scanning a barcode stickered to the devices The device then can be immediately configured and later only a scan of the reception quality and a short recheck of the device i...

Страница 27: ...so helpful to configure the Barcode Scanner in a way that it will add a Tabulator sign after a data scan In that case pressing the Verify button would no longer be necessary and the Barcode would be c...

Страница 28: ...ill be replaced by the scanned device Already changed settings to the selected device will be transferred the selected device will be removed of the project After the desired settings have been made c...

Страница 29: ...lace device You can replace defective devices with new ones Transfer virtual device funtions Transfers the function of selected virtual devices to real devices Scan The reception area is scanned for E...

Страница 30: ...Eaton RF System Help 2015 Eaton Electrical Group There are some main supplied devices already scanned how you can see in the part list and the reception area is scanned for further main supplied devic...

Страница 31: ...will be added to the part list New main supplied devices are scanned as long s you press the button switch to battery supplied devices You can switch back to main supplied devices every time but it s...

Страница 32: ...new menu item Actions Scan reception quality the reception quality of all known devices can be scanned separately Scan reception quality By using this command the reception quality of all devices on...

Страница 33: ...ilt in position of the devices in an existing system this is where you have the possibility to recalculate all the connections after a Scanning process including the routing paths The calculation is b...

Страница 34: ...r The list will help you to see the progress The name of the device that is currently loaded will be bolded You can scroll through the list at any time to see which devices are still waiting to be loa...

Страница 35: ...ton RF System 2015 Eaton Electrical Group All devices that must be loaded are additionally displayed as question marks but keeps their name After the device has been loaded the symbol is shown normal...

Страница 36: ...ut such devices the function cannot be used Depending on the result of the calculation the user will be informed whether resenders have been found for all status connections or not and for what status...

Страница 37: ...ossible successful calculation of resenders necessary Reset all Devices All the devices which are scanned and can be seen on the screen will be reset to the state at the time of their delivery All the...

Страница 38: ...ayed on the battery status full almost full average weak and empty and or whether the device is powered New for 2 30 Now also system and configuration messages will be displayed to have better analyza...

Страница 39: ...roject names By selecting the project name entering a name in the name field and clicking on the New button a new Level 1 area is created By selecting a Level 1 area entering a name and clicking on th...

Страница 40: ...ea and all sub areas can be deleted from the project Devices that are allocated to one of these areas will be set to No allocation The current project topology can be exported to a file using the Expo...

Страница 41: ...he individual routing segments To be able to use this function the option Allow the use of manual routing must first be activated in the programme options Following this activation the function can be...

Страница 42: ...bility that you have to select the sensor channel multiple times for each of the resulting connections is possible if multiple connections are set up as a result of the drawn out routings Replace devi...

Страница 43: ...nctions With this function you can transfer all the settings and connections of virtual devices to real devices As a result the virtual devices are removed from the project At least one virtual device...

Страница 44: ...n to select a connection result and to delete it at any time by pressing the button Both devices would then be returned to their respective lists With the option Transfer the reception quality of virt...

Страница 45: ...of individual devices are transferred separately For information Similar to the function Replace device the Bluethooth configuration of a Room Manager with Bluetooth will not be transfered Commands o...

Страница 46: ...ee Gateway Go Offline Use this command to disconnect the Gateway Go to menu item Gateway and select Go off line to disconnect the Gateway Also see Gateway Identify Use this command to identify the con...

Страница 47: ...nt functions through the mouse In order to show or hide the tool bar you can select the command Tool bar from the View menu ALT A S The MRF 2 0 version provides 2 different display formats for the too...

Страница 48: ...roperties into an actual project Imports virtual devices from a database into the current project Zooms the workspace to 100 Zooms the workspace to 50 Provides Information about the Eaton RF System St...

Страница 49: ...defined Project Topology window Activates deactivates the window for the Topology View In the process a window to the left of the workspace will appear and display the current topology structure By ri...

Страница 50: ...clicking on an area in the Project Topology window a pop up menu will appear with the following new options Copy devices copies all devices in this area to the clipboard Insert copied devices pastes t...

Страница 51: ...of the Project notes can be activated deactivated in 2 different ways 1 Menu View Project notes 2 Right click on blank MRF workspace Show project notes see also Insert project notes Normal view 100 Wh...

Страница 52: ...t intelligent device in the actuator sensor list and cannot be routed and is also not repeated by the actuator In earlier MRF versions the old Status message has only been sent by an actuator that was...

Страница 53: ...ation The new status connection is generally an own back channel from the actuator new generation to the intelligent device that supports this special channel The connection path can be direct or rout...

Страница 54: ...no reception quality none no reception quality Should you wish to see the reception quality of a particular device you can display the reception quality of this particular xComfort device by right cli...

Страница 55: ...the new generation are at 50 maximum capacity You can also delete the reception quality between two routers in the router view This may be helpful if there are two routers in the direct vicinity which...

Страница 56: ...e Pendant remote control MEP device Ethernet CI Radiator thermostat Multi Heating actuator USB RF Communication Stick Smart Home Controller Switching Actuator General information The switching actuato...

Страница 57: ...on Moving the mouse pointer to the different command icons will display a tool tip which briefly explains how to trigger this command 3 The box top right includes the following command buttons OK Conf...

Страница 58: ...g Actuators Output is blinking 15 seconds before it switches OFF Push button Key Mode occupies 2 command buttons The Switching Actuator is only ON while its sensor is activated Otherwise it is OFF Sur...

Страница 59: ...electable for and Push button Key Mode free selectable for and Surge free selectable for and Blinking free selectable for and Configuration Example for Switching Actuator Dimming Actuator General info...

Страница 60: ...e push button long push at the top of the push button long push at the bottom of the push button and short push at the bottom of the push button Moving the mouse pointer to the different command icons...

Страница 61: ...upies 4 command buttons Switches ON presp OFF On Switch on Delay occupies 1 command button ON command that comes either immediately or after an adjustable delay time Off On with Switch off Delay occup...

Страница 62: ...before off can be selected at random from and Surge Standard only selectable for Blinking free selectable for and Desired Brightness free selectable for and Dim brighter can be selected at random fro...

Страница 63: ...one of these sensors you can select the function you want to carry out 2 The next box top center depends on the sensor and displays the commands a sensor can send to an actuator They are depicted as...

Страница 64: ...object Every sensor for example a binary input with a wind or solar sensor that has been assigned to the actuator and configured with the function Safety function when ON or Safety function when OFF N...

Страница 65: ...red Runtime Close occupies 1 command button Close for the length of the configured Runtime Stop occupies 1 command button Stop Command Sequencer occupies 1 command button Toggles with every Command in...

Страница 66: ...t Bat 230 Mode2 and Mode3 Switch Open free selectable for and Standard for Close free selectable for and Standard for Stop free selectable for and Functions for Room Controller and Temperature Input O...

Страница 67: ...hbutton you have to draw a connection from either the left or right side of the device icon to assign a connection from the left or right rocker If you draw a connection from a 4 fold pushbutton to a...

Страница 68: ...68 Eaton RF System Help 2015 Eaton Electrical Group Configuration window 2 fold pushbutton Configuration window 4 fold pushbutton...

Страница 69: ...el B where the voltage applied can be measured see Instructions for Installation and from where different commands can be sent depending on the value and configuration mode of the binary input Battery...

Страница 70: ...he push button and a long push at the push button With channel B we distinguish between ON contact closed and OFF contact open Mode 4 In this mode both inputs A and B are combined so they offer the sa...

Страница 71: ...ettings and returns to the MRF main window OK Load Confirms returns to the MRF main window and immediately loads the modifications into the device Cancel Discards the modifications entered and returns...

Страница 72: ...ng contacts A and B you can select whether or not the status is to be sent cyclically If you select send cyclically the cycle time default 1 hour minimum 10 minutes to maximum 18 hours can be set by m...

Страница 73: ...tuator etc it can also send information temperature to the Home Manager Room Manager etc In order to scan the room controller turn the adjustment wheel to the upper lower stop or actuate the activatin...

Страница 74: ...s sent But it is also possible to set a hysteresis standard 0 5 C This will be explained in detail in an example that follows later A second switching point can be entered for the new room controller...

Страница 75: ...nother device the line is drawn from the left side of the icon whereas it is drawn from the right for humidity values See also Configuration Example for Room Controller Temperature Input The temperatu...

Страница 76: ...ed is lower than the pre set switching point the command below is sent If the temperature measured exceeds the pre set switching point the command beyond is sent But it is also possible to set a hyste...

Страница 77: ...vice is battery supplied it will work for an extended period of time 6 hours with permanent operation without any external power supply USB RF Configuration Stick It can be connected to a PC or Laptop...

Страница 78: ...Electrical Group Open the Folder Universal Serial Bus Controllers Double click every single USB Root Hub and Generic USB Hub and deactivate the option Allow the computer to turn off this device to sav...

Страница 79: ...to other xComfort devices is established by means of datapoints As soon as a connection has been drawn from a device to the Home Manager RF the Home Manager datapoint window will open There you can se...

Страница 80: ...x 20mA control signal und its functions are similar to the dimming actuator With the additional relay loads can also be switched By using the MRF configuration window you can enable or disable the rel...

Страница 81: ...top of the push button long push at the bottom of the push button and short push at the bottom of the push button Moving the mouse pointer to the different command icons will display a tool tip which...

Страница 82: ...direct percentage value command 0 100 by dimming to that value instead of immediately jumping to that value The set dimming time will be taken into consideration The option will only be available if t...

Страница 83: ...Switch On Off Standard ON OFF only selectable for On Switch on Delay free selectable for and Off Switch off Delay free selectable for and Off with preliminary Warning free selectable for and Flashing...

Страница 84: ...motion Moving away the finger in under 1 second a short key press is detected a short click sound is played 2 Long key press Operation somewhere in the ring shaped sensor area without circular motion...

Страница 85: ...Manager is divided in several pages In its basic state only 3 pages Room 1 Time and Date and Miscellaneous are active According to the configuration more pages are generated Room 1 The room temperatur...

Страница 86: ...n about configuration possibilities and operation of the several pages functions you can find by following the links below Heating and cooling and the Room Manager Ventilation and the Room Manager Sha...

Страница 87: ...umidity measurement Room 1 to 6 or only used as an input Once a temperature sensor and a heating cooling actuator is assigned the room can be configured You can change the set points for the temperatu...

Страница 88: ...is displayed The normal function switching light etc is deactivate if a room main page is displayed and active if another main page is displayed Connection to a RF Radiator thermostat If there is one...

Страница 89: ...Operation type output needs to be connected to the channel Heating Cooling of the Multi Heating actuator for details see Operation Mode and Type toggle of the Room Manager Rooms of the Room Manager t...

Страница 90: ...tors Possible cooling request connections for a room only actuators Switching Dimming Analog Shutter actuator Channels of intelligent devices Multi Heating actuator as cooling request In this configur...

Страница 91: ...if single or multiswitching of actuators By using the sensor wheel you can operate the outputs On Off Dim Devices that can be assigned to a output are switching actuator dimming actuator analogue act...

Страница 92: ...nager Ventilation control with the Room Manager One or more actuators can be assigned to a unique ventilation output that is controlled by a timer On the ventilation page of the Room Manager the room...

Страница 93: ...s and the Room Manager Up to 10 different inputs can be defined temperatures binary values analogue values and displayed in the Room Manager If you have binary values you can define the displayed text...

Страница 94: ...he Shadings open close step up step down For every shading you can define a timer in which you can set at what time the shading should be opened or closed Additionally the shading group can be control...

Страница 95: ...e and Operation type toggle Any binary sensor or binary outputs of other intelligent devices can be connected to that inputs For Room Managers with a software version under V40 only the input for Oper...

Страница 96: ...d sensors the operation type can be set to none heating only cooling only and Heating and Cooling ATTENTION If a Multi Heating actuator is used in any Room it is necessary to set heating only for OFF...

Страница 97: ...timer is ON and beyond the time it is OFF For every day you can define 3 different time spans directly in the Room Manager or by using the MRF programme The actual state and the operation mode for ea...

Страница 98: ...outdoor temperature main page At the outdoor temperature main pages are the outdoor temperature and two further values as the MIN MAX measured outdoor temperature inputs e g brightness wind speed the...

Страница 99: ...tputs that are defined in the Room Manager can be used for the presence simulation and will be switched ON and OFF selective for unsteady times 10 to 60 minutes The start of the presence simulation ca...

Страница 100: ...Room Manager you can use the extended functions Logic functions at the Room Manager With the logic functions on the Room Manager you can switch binary and analogue outputs shadings or markers if the s...

Страница 101: ...the configuration window of the Room Manager you can use the extended functions Scenes on the Room Manager With a scene you can switch up to 6 different binary and analoge outputs shadings and marker...

Страница 102: ...after clicking OK and re opening the configuration window of the Room Manager you can use the extended functions General Information on the Room Manager with Safety Function Overview The Room Manager...

Страница 103: ...he window contacts of the existing rooms can also be included in the surveillance All smoke detectors via binary input need to be assigned to a smoke detector input at the Room Manager max 5 smoke det...

Страница 104: ...on looks like You can do the following settings Field 1 This is where the code can be defined for the customer to acknowledge an alarm It is also possible to either allow or not allow the customer to...

Страница 105: ...upon activation switch it off upon deactivation Field 6 This is where you can define what actions should be started in case of an alarm In case of an alarm it is possible to switch on 2 different out...

Страница 106: ...age within that preset time the alarm will be triggered Field 5 Under Zone you can assign the Safety Inputs to the different safety zones zone 1 zone 2 zone1 2 Field 6 Here you can display the names o...

Страница 107: ...e a status message from the smoke detector input If the Room Manager does not receive a status message within that preset time the alarm will be triggered Field 4 Here you can display the names of the...

Страница 108: ...mption values to the Room Manager Since MRF 1 60 and RM V38 it is possible to connect the xC MEP device which is connected to a Smart Meter with the Room Manager The following functions can be carried...

Страница 109: ...m Manager you will now see a new tab with the number of this energy input This is what the Settings window for the energy input with impulse input looks like General information Name This is where the...

Страница 110: ...ariff per measuring unit Please enter the tariff per measuring unit CO2 per kWh If you have selected kWh or Wh as a variable to be measured you can enter the CO2 factor per kWh here Threshold value su...

Страница 111: ...e a new tab with the number of this Energy input This is what the Settings window for an Energy input with Energy measuring sensor looks like General information Name Here you can enter the name of th...

Страница 112: ...at the display of the Room Manager but they can be changed at any time again via the Settings menu in the Room Manager Possible settings for the display dependend if consumer or generator is selected...

Страница 113: ...113 Eaton RF System 2015 Eaton Electrical Group This is what the setting window for the energy input assigned to a tariff energy channel of the xC MEP device looks like...

Страница 114: ...nager and the calculation of the costs Show text or chart page on the Room Manager It is possible to display or to hide the text or the chart page of this energy input Settings for costs Here you can...

Страница 115: ...any time again via the Settings menu in the Room Manager Settings possible for the display dependend on if consumer of generator is selected Values for xC MEP device total energy channel total active...

Страница 116: ...elected source is fixed defined for Pos 1 Pos 2 the energy consumption of the selected source is fixed defined for Pos 2 The time area can be changed as desired Pos 3 the present energy areas outdoor...

Страница 117: ...ilable energy inputs The settings if an input is a generator or a consumer will be considered For each line it is possible to define a different time area Further you have the option to display a char...

Страница 118: ...can define up to 3 predefined SMS texts It can be selected for sending in the alarms page It can also be chosen to use the first message for the beginning of a status message Room Manager with Blueto...

Страница 119: ...defined duration before sending out the SMS max 120 minutes 0 minutes 30 seconds The SMS will be sent to the phone number that is selected afterwards If you chose in the next line wait for confirmatio...

Страница 120: ...ough the call will not be picked up As event you can select a desired output or marker to be set to ON OFF or being toggled Room Manager signalizes event by call You can define to call a desired phone...

Страница 121: ...tically generate Bluetooth passkey If this option is activated the key that is used to establish a connection to another device is generated automatically Enter passkey You can define a passkey manual...

Страница 122: ...nd controlling of objects Beginning of every SMS Password afterwards object name following for request for control state There is the possibility to request or control more than one object with only 1...

Страница 123: ...123 Eaton RF System 2015 Eaton Electrical Group State Syntax of RM to user...

Страница 124: ...ry mobile phone is acting the same it is recommended to only use devices that has been tested by Eaton The real connection to the mobile phone must be done by using the Room Manager menu Bluetooth and...

Страница 125: ...ware has been loaded successful a window pops up that informs you and the Room Manager restarts You have to rescan the Room Manager so that the MRF eventually detects changes made by the software upda...

Страница 126: ...e sent to the Room Manager Home Manager and the Comm interface Channel A is the detection output and sends depending on the ambient light value a ON command if movement is detected and after a adjusta...

Страница 127: ...automatically switches OFF Now if new movement is detected in this time the delay time begins to run new So for example the light is at least ON for the defined delay time if no new movement is detec...

Страница 128: ...me goes for channel B So that s how you can assign the motion detector to actuators or activate it for scanning in the comfort mode When you do a long key press of the activation key the channel that...

Страница 129: ...face itself merely serves as a communication tool whilst the process is controlled by means of the software in the connected device Allocations from devices can be made in Comfort Mode but also functi...

Страница 130: ...real USB interface Several communications interfaces can also be connected to one device server via a USB hub or several device servers can be connected to one communications interface Eaton has test...

Страница 131: ...t at Analog input The analog input is a mains powered sensor and can control all xComfort actuators switching actuator dimming actuator shutter actuator analog actuator or it can send a measured value...

Страница 132: ...If the measured value is lower than the pre set switching point the command below is sent If the measured value exceeds the pre set switching point the command over is sent But it is also possible to...

Страница 133: ...ured and converted value is sent by menu item Send measured value You can select how many times and how precisely the value should be measured and sent and whether it is to be sent as part of a cycle...

Страница 134: ...itching actuator dimming actuator shutter actuator etc but it can also send commands to the Home Manager Room Manager etc e g to start complex processes The functions of this remote control are almost...

Страница 135: ...he yellow LED lights up briefly if you actuate it twice the green LED lights up briefly The switch rocker functions as a single button and should be regarded as 1 sensor channel A command is sent when...

Страница 136: ...an then choose the appropriate channel which you wish to allocate The command button rocker of the 12x remote control can send the following commands short press on the button top long press on the bu...

Страница 137: ...Basic Mode see installation instructions for further information New since Software Version 10 Routers with a software version of 10 or higher are Routers of the new generation The general performanc...

Страница 138: ...ers or the status of one of the 5 output channels can also be selected if available Depending on the selection of the logic operation the second input variable can also be a fixed value set by the use...

Страница 139: ...e impulse input has two 32 bit counters 1 for each channel and counts all impulses at its S0 inputs in absolute figures until they are reset or until they are supposed to run over The maximum counting...

Страница 140: ...no further action is carried out the remote control will switch to standby mode again after a pre defined time default is 10 seconds All timers will of course continue to operate in standby mode Also...

Страница 141: ...he respective timer to stay ON If the option Activate cyclical sending is active the status of the timer will be sent to the assigned output every hour on the hour Also refer to chapter General Inform...

Страница 142: ...RF read in the remote control into which you want to load the new software 2 Make sure your infrared interface at the PC Laptop has been activated 3 Activate the infrared interface of the Remote Contr...

Страница 143: ...lso refer to chapter General Information on the Remote Control with Display Energy measuring sensor The Energy measuring sensor measures various consumption related values active power voltage and cur...

Страница 144: ...e measured can be activated deactivated and the accuracy of measuring can be adjusted Current The transmission of this variable to be measured can be activated deactivated and the accuracy of measurin...

Страница 145: ...om Manager 1 Operation without Room Manager or Room controller In this mode the temperature measurement and set value preset is given by the radiator that is connected to the heating actuator The conf...

Страница 146: ...m controller via the switch It can be defined if the actual temperature and the set value preset is given by the Room controller or the radiator After assigned to the heating actuator you can set the...

Страница 147: ...147 Eaton RF System 2015 Eaton Electrical Group 3 Operation with Room Manager The heating actuator is assigned as the heating request for a room of the Room Manager minimum firmware version is 6 35...

Страница 148: ...eating actuator will react after a power failure Backup mode As long as no new control commands or temperature commands are received by its assigned devices all control commands will come from the con...

Страница 149: ...y input in Mode 1 ON Einzeltaste UP Press UP RELEASE Different to normal sensors the device will repeat a command more often if it will not be acknowledged So it has an improved transmission guarantee...

Страница 150: ...l configuration and the activation of the option The MEP device has been configured and can now used a connection to another device can be drawn Following connection possibilities are maximal availabl...

Страница 151: ...n of the energy vlaue activated deactivated and definition of the cyclical time Power value Transmission of the power value activated deactivated and definition of the cyclical time Tariff info Transm...

Страница 152: ...lue activated deactivated and definition of the cyclical time Rate 3 Energy value Transmission of the rate 1 Energy value activated deactivated and definition of the cyclical time Rate 4 Energy value...

Страница 153: ...uration and cyclical transmission every hour of the status of each rate output only if the rate is active see Overview MEP device MEP device General outputs This page displays the connected devices to...

Страница 154: ...154 Eaton RF System Help 2015 Eaton Electrical Group see Overview MEP device MEP device General On this page general information is displayed and the enabling of the MEP device can be done...

Страница 155: ...ed The version verify shows if the software version of the MEP device is equal to the scanned version in the MRF project see Overview MEP device RF Radiator thermostat The RF Radiator thermostat serve...

Страница 156: ...ly the temperature measured near the radiator can be different than the temperature in other areas of the room So you can make sure that the thermostat will regulate to the right temperature in the ro...

Страница 157: ...e thermostat will regulate to the night temperature Using the Copy function you can copy the times of a day to another Autonomous manual Set value Here you can define the Set value for the manual mode...

Страница 158: ...ated Request Regulation time You can set the time that the device will communicate with the intelligent device in order to get a new Set and actual temperature If new data has been received the valve...

Страница 159: ...es can be done by a 3rd party application that has access to the ECI over Ethernet Routing of connections between xComfort RF devices over Ethernet If there are at least 2 ECI in the project it is pos...

Страница 160: ...eds to have a unique IP address For the Ethernet Routing it is important that all devices are loaded and that there are no ECI with the same IP address in the project In the MRF options you have the p...

Страница 161: ...ame for the datapoint list can be entered max 11 characters When selecting download by RF the datapoint list will be downloaded to the memory of the ECI where it can be used by other applications The...

Страница 162: ...etwork test Clicking START will trigger a ping request from this ECI to all selected While the test is running the state of the respective ECI will be pinging The result will also be displayed in the...

Страница 163: ...exadecimal number 0 9 A F Net Prefix Length Length of the Ipv6 Net prefix Ethernet Routing Allow Etherner Routing If this option is activated the ECI can be used as Ethernet Router and will be conside...

Страница 164: ...e mounting instruction General information about the different channels of the Multi Heating actuator Heating inputs 1 12 Inputs for Set and Actual temperature from Room controllers Room Manager etc S...

Страница 165: ...Manager Each Room can be connected to multiple inputs of the Multi Heating actuator but each input can only have one connection If an input of the Multi Heating actuator is used for Heating only Cool...

Страница 166: ...datapoint of a Home Manager or other intelligent device Each datapoint can be connected to multiple inputs of the Multi Heating actuator but each input can only have one connection If an input of the...

Страница 167: ...RF Communication Stick The USB RF Communication Stick is used to enable the Eaton wireless system to communicate with the PC e g using display software or a different control system The connection to...

Страница 168: ...y inactive When making connections in the basic mode the LED has the same functionality as a LED of an actuator When the device is resetted using the pushbutton it will blink as described in the mount...

Страница 169: ...on of all interfaces can be done by the MRF It is also possible to copy the project by the MRF and reuse it Making connections The connection to other xComfort devices is done using data points If you...

Страница 170: ...f the listed interface the IP address of the SHC is not static and therefore not displayed All ECI need to have a valid and unique IP address You can change the IP address of an ECI by right clicking...

Страница 171: ...onnection List In Connection list all device channels connected to the SHC or any of its extension interfaces ECI will be shown There are different configuration possibilities for each connected devic...

Страница 172: ...onnected device channel how it will be displayed later in the Smart Home Controller This name can be freely edited max 40 characters Function Defines the function of the connected device channel if no...

Страница 173: ...simply can be displayed in the SHC The desired unit can be defined in Column Extra setting 1 Outdoor temperatu re Analog input Channel A B Marker Analog Input Temperature input Ch A B A temperature va...

Страница 174: ...in Extra 2 and Extra 3 max 10 characters and is if nothing is defined MOTION or NO MOTION General Energy sensor Energy Ch Impulse input Ch A B Switching actuator Energy Ch A general Energy or counter...

Страница 175: ...mate function Depending on the connected device type it is treated as a binary or analog value Main cooling Switching actuator Actuator Dimming actuator Analog actuator An output for a sum cooling req...

Страница 176: ...a 2 Gas Impulse input Channel A B The value of a Gas meter that can be used in the Energy function or simply be displayed in the SHC The counter constant impulses per measured unit can be defined in c...

Страница 177: ...e statistic for Top Consumer Producer of a Zone Can be used in an Energy function or simply be displayed in the SHC The counter constant impulses per measured unit can be defined in column Extra 1 and...

Страница 178: ...lso be used in Macro Scenes to trigger events etc Marker type Use similar as Explanation Marker Binary output Switching actuator Can be programmed with a simple logic e g State should be set to ON or...

Страница 179: ...where the type cannot be determined correctly when drawing a connection in the MRF will be created as generic device channels in the Smart Home Controller Connections to the following devices are aff...

Страница 180: ...ng Remove Zone will delete a Zone from the project using Add Zone will add a new Zone to the project and using Rename Zone will change the name of a Zone A zone can have a name with a maximum of 40 ch...

Страница 181: ...it is no longer necessary to load the Datapoint list into the Smart Home Controller Additionally to the SHC Configuration a copy of the actual MRF Project is also saved to the ZIP File It will also be...

Страница 182: ...switching actuator Varia nt Symbo l Type designation Type name max Load max ambient temperature Binary input Energy function Old CSAU 01 01 Switching actuator old 8A R L 5 45 C 0 CSAU 01 01 10 Switch...

Страница 183: ...e own actuator function and or connected to other xComfort devices The type with the Energy measurement function will additionally measure the active power and record the Energy of the connected Load...

Страница 184: ...uts of intelligent devices Output 2 Energy Energy value in X XXXkWh Room Manager Energy input all inputs of intelligent devices Inputs Router Output 3 Power active power in X XW Room Manager Energy in...

Страница 185: ...uator Function Configuration window actuator function After drawing the desired connections to the actuator right click the device symbol and select Settings to open the configuration window Depending...

Страница 186: ...t to carry out The possible functions are depending on the type of the sensor resp the RF Commands of the sensor The different colored frames around the sensor symbols have the following meaning only...

Страница 187: ...entered and returns to the MRF main window Cancel Discards the modifications carried out and returns to the MRF main window Info Opens the Help dialog for Switching Actuator 10A All functions of the S...

Страница 188: ...ches the output ON again is only possible if the internal temperature falls below 15 C of the maximum value Functions for Pushbuttons Remote control intelligent devices and Binary inputs Mode 4 On Off...

Страница 189: ...and Activate Lock free selectable for and Release Lock free selectable for and See also Switching actuator 10A 16A General Switching actuator 10A 16A Binary input Switching actuator 10A 16A Energy me...

Страница 190: ...ee all configuration possibilities for the Energy measurement function Energy For the output channel of the energy the cyclic time can be set between 10 minutes and 1 hour Power The sending frequency...

Страница 191: ...entered minimum nominal Load If that is the case the output will switch to ON otherwise it s OFF as long as this error state is active If the entered value is 0 the function is disabled Generally we r...

Страница 192: ...will behave like an old actuator and send the status message in the old format and also not from the status channel This also applies to the mixed mode of old and new connected intelligent devices The...

Страница 193: ...193 Eaton RF System 2015 Eaton Electrical Group...

Страница 194: ...on Send Status Message after a state changes is activated the extended Status message will be sent automatically every time the Output State changes Changes to other information will not trigger the s...

Страница 195: ...e for a group of 60 devices Configuration examples Configuration example Switching actuator Configuration example Dimming actuator Configuration example shutter actuator Configuration example Room con...

Страница 196: ...System Help 2015 Eaton Electrical Group 3 The standard function ON OFF at and is pre set and will not be modified Instead we click the command button next to long push at the top of the key to assign...

Страница 197: ...197 Eaton RF System 2015 Eaton Electrical Group 4 Now we select the desired function e g On switch on delay...

Страница 198: ...select the control time and delay time in the functions box by using the slider controls Control time Indicates how long a key needs to be activated until the function is started in the switching actu...

Страница 199: ...199 Eaton RF System 2015 Eaton Electrical Group 6 Then we select the command button for long push at the bottom of the key...

Страница 200: ...200 Eaton RF System Help 2015 Eaton Electrical Group 7 And assign the function Blinking to it...

Страница 201: ...on RF System 2015 Eaton Electrical Group 8 Again select the control time 1 second and the interval time 10 seconds An interval time of 10 seconds means that the output will change its status every 5 s...

Страница 202: ...202 Eaton RF System Help 2015 Eaton Electrical Group 9 Now that all functions have been configured let us select the behaviour in case of power recovery Off...

Страница 203: ...5 Eaton Electrical Group 10 The switching actuator configuration is completed and we confirm the configuration by pressing the OK command button which closes the configuration window and takes us back...

Страница 204: ...ator In this item you will learn how and why to set a dimming time a desired brightness value and dimming limits In our example let s use the hand held transmitter for the dimming actuator We assign t...

Страница 205: ...205 Eaton RF System 2015 Eaton Electrical Group 2 Then we change the dimming limits from the standard setting 20 to 100 to 40 to 90...

Страница 206: ...starts dimming at 40 brightness and will reach a brightness of 90 within 2 seconds These settings are only valid for the function Dimming at not for the function ON OFF at 3 Then we click the functio...

Страница 207: ...the Switching Actuator A shutter actuator has no selection options for operating status after power recovery nor for Blinking in case of a low sensor battery The only time related settings that can b...

Страница 208: ...f the Room Controller Sending a switching command A room controller is supposed to send a switching command to a switching actuator valve at a switching point of 25 C hysteresis 1 C 1 Connect the room...

Страница 209: ...is not until a temperature of 24 C as the hysteresis is 1 C is reached that it sends beyond The reaction depends on the configuration of the switching actuator Sending a temperature value The room con...

Страница 210: ...mware is also shown please also update the RF Firmware as well 2 Wait until the SHC has completely restarted after the update Power LED must be green 3 Save the SHC Configuration over 2 System Export...

Страница 211: ...Push button 1 fold Push button 2 fold Push button 1 fold left rocker Push button 2 fold right rocker 4 fold pushbutton 4 fold pushbutton Rocker 1 4 fold pushbutton Rocker 2 4 fold pushbutton Rocker 3...

Страница 212: ...e been scanned yet Analog actuator setting 0 10V Analog actuator setting 1 10V Analog input Analog input Channel A Analog input Channel B 2x remote control 12x remote control Room controller humidity...

Страница 213: ...tor 10A 16A Internal Binary input Mode 2 of Switching actuator 10A 16A New Router New Router with Logic Frame for a device that has been imported by Barcode Scan and not yet been checked by RF See Bar...

Страница 214: ...ied device in between the sensor and the target actuator This is the so called Router So that the message can not be sent directly from the sensor to the target it goes from sensor to router and from...

Страница 215: ...group member does not acknowledge the command however they only know that they are part of the group and repeats the command of the sensor identically We call this behaviour resend Now not every memb...

Страница 216: ...able to use this function one sensor and at least one actuator that has a connection to that sensor has to be selected For executing this function you have to right click the sensor and choose the opt...

Страница 217: ...ep 1 Select the desired actuators the sensor and start the function Step 2 Select the sensor channel For all devices but AA1 and JA1 the connection of FB 2 fold left rocker will be configured now Step...

Страница 218: ...218 Eaton RF System Help 2015 Eaton Electrical Group Step 4 Configuration of device type dimming actuator...

Страница 219: ...219 Eaton RF System 2015 Eaton Electrical Group Step 5 Configuration of device type analogue actuator...

Страница 220: ...220 Eaton RF System Help 2015 Eaton Electrical Group Step 6 Configuration of device type shutter actuator...

Страница 221: ...ould be done before you make connections to other devices This function is available for the following devices Switching actuator Dimming actuator Analogue actuator Heating actuator Binary input batte...

Страница 222: ...arameter can be configured Process If you select more than one device with the selection mode there will be the option configure group basic settings The function will only work if the selected device...

Страница 223: ...223 Eaton RF System 2015 Eaton Electrical Group Group settings analogue actuator...

Страница 224: ...224 Eaton RF System Help 2015 Eaton Electrical Group Group settings heating actuator...

Страница 225: ...225 Eaton RF System 2015 Eaton Electrical Group Group settings binary input battery supplied...

Страница 226: ...226 Eaton RF System Help 2015 Eaton Electrical Group Group settings binary input 230V Group settings Motion detector...

Страница 227: ...227 Eaton RF System 2015 Eaton Electrical Group Group settings Temperature input...

Страница 228: ...228 Eaton RF System Help 2015 Eaton Electrical Group Group settings Room controller Group settings Room controller with humidity...

Страница 229: ...229 Eaton RF System 2015 Eaton Electrical Group Group settings Analogue input Group settings Impulse input...

Страница 230: ...230 Eaton RF System Help 2015 Eaton Electrical Group Group settings Energy measurement sensor Group settings BOS COS Interface...

Страница 231: ...ll be done to all selected devices Device Pop up Menu The Drop Down Menu serves for sending commands directly to the actuator or sensor for carrying out settings or for displaying properties such as r...

Страница 232: ...he reception quality for this device new New for 1 40 Reception quality The reception quality of this device can now be displayed with respect to all the other devices in the system in table form by m...

Страница 233: ...apters or devices which are not always connected to the mains Change name Option to change the device name Load password Loads the defined system password in the device New with 2 00 Copy selected dev...

Страница 234: ...background grafic Shows or hides the background image Create group frames Activates the Create Group Frames mode Display group frames Shows or hides the group frames Create project note Executes the...

Страница 235: ...ning and using the Skip button will continue scanning without changing the device name Connection wizard The function serves to create large group connections fast and without the manual drawing of co...

Страница 236: ...g a topology area a filter is applied and the devices in this area are displayed in Selection Connection to device type Here a filter for the device types of the displayed devices can be applied in th...

Страница 237: ...not possible to delete connections with it Instead connections will always be added with the additional selection of actuators Device note Option to enter a note for an individual device The informati...

Страница 238: ...ning will proceed normally and devices that have passwords different from the current project password will be fully scanned but will be displayed with a blocked symbol After scanning you have the opt...

Страница 239: ...word to one or more devices you will have the option to reset them using the Forgot button however you must have On Site Access to the devices If this involves sensors you must energise activate them...

Страница 240: ...ect will also be reset to No password The password can also be deleted individually from one device via Device drop down menu delete password However parameterization and assignments to other xComfort...

Страница 241: ...re not digitally signed by Microsoft In this case the Software Update function will show the error message Driver installation failed 536870353 The following changes are necessary to allow this functi...

Страница 242: ...n RF System as administrator in 2 different ways 1 Run only once as Administrator Right click on the shortcut of the Eaton RF System and select the option Run as Administrator 2 Always run as Administ...

Страница 243: ...windows installation it may happen that Windows wants to search for a driver automatically using the Windows update function before it allows the MRF to do the driver installation If that is the case...

Страница 244: ...een prepared by the MRF will be installed and the software update can continue If the software update has already been canceled because of the driver installation timeout simply restart it again This...