26
Chapter 1 Before Operation
Copyright © 2019 Duplo Corporation All Rights Reserved
6-10. Folding A/Folding B input screen
[6]
[8]
[7]
[2]
[1]
[5]
[6]
[8]
[7]
[4]
[3]
[5]
No.
Name
Function
[1]
Folding A setting value display
Displays the currently set folding A value.
[2]
Folding A outline display
Displays the position of folding A on the paper.
When the input value is outside the specification range, a warning message
is displayed.
[3]
Folding B setting value display
Displays the currently set folding B value.
[4]
Folding B outline display
Displays the position of folding B on the paper.
When the input value is outside the specification range, a warning message
is displayed.
[5]
(Return) key
Saves the input value and returns to the [Custom Fold] screen.
[6]
(Clear) key
Sets the input value to "0".
[7]
Numeric keypad
Inputs the value.
Setting range
Folding A: 42.0 to *** mm/1.65 to *** inches
***: 325.0 mm/12.80 inches or “Paper 5.0 mm/+0.197 inch”,
whichever is shorter.
Folding B: 0/47.0 to *** mm/1.85 to *** inches
***: 217.0 mm/8.54 inches or “Paper 5.0 mm/+0.197 inch”,
whichever is shorter.
[8]
(Cancel) key
Returns to the previous screen without saving the input content.
Press and hold to return to the [Ready] screen.