redundancy 299
redundancy
Table 52
redundancy properties
Name
Type
Description
redundancy-mode
string
The system’s operating mode, also called the cache redundancy mode.
•
Independent Cache Performance Mode
: For a dual-controller system,
controller failover is disabled and data in a controller’s write-back cache is
not mirrored to the partner controller. This improves write performance at the
risk of losing unwritten data if a controller failure occurs while there is data
in controller cache.
•
Active-Active ULP
: Both controllers are active using ULP (Unified LUN
Presentation). Data for volumes configured to use write-back cache is
automatically mirrored between the two controllers to provide fault tolerance.
•
Single Controller
: The enclosure contains a single controller.
•
Failed Over
: Operation has failed over to one controller because its
partner is not operational. The system has lost redundancy.
•
Down
: Both controllers are not operational.
redundancy-
mode-numeric
uint32
Numeric equivalents for
redundancy-mode
values.
•
1: Independent Cache Performance Mode
•
2: Active-Active ULP
•
3: Single Controller
•
4: Failed Over
•
5: Down
redundancy-
status
string
•
Redundant with independent cache
: Both controllers are
operational but are not mirroring their cache metadata to each other.
•
Redundant
: Both controllers are operational.
•
Operational but not redundant
: In active-active mode, one
controller is operational and the other is offline. In single-controller mode,
the controller is operational.
•
Down
: This controller is not operational.
•
Unknown
: Status information is not available.
redundancy-
status-numeric
uint32
Numeric equivalents for
redundancy-status
values.
•
0: Redundant with independent cache
•
1: Redundant
•
3: Operational but not redundant
•
4: Down
•
5: Unknown
controller-a-
status
string
•
Operational
: The controller is operational.
•
Down
: The controller is installed but not operational.
•
Not Installed
: The controller is not installed.
controller-a-
status-numeric
uint32
Numeric equivalents for
controller-a-status
values.
•
0: Operational
•
1: Down
•
2: Not Installed
controller-a-
serial-number
string
•
Controller module serial number
•
Not Available
: The controller is down or not installed.
controller-b-
status
string
•
Operational
: The controller is operational.
•
Down
: The controller is installed but not operational.
•
Not Installed
: The controller is not installed.
Содержание AssuredSAN 6004
Страница 11: ...Document conventions and symbols 11 TIP Provides helpful hints and shortcuts...
Страница 58: ...58 Alphabetical list of commands exit Description Log off and exit the CLI session Min role monitor Syntax exit...
Страница 107: ...set led 107 Identify drawer 1 in enclosure 1 set led drawer 1 1 on Identify fan 1 in enclosure 1 set led fan 1 1 on...
Страница 114: ...114 Alphabetical list of commands See also set cli parameters show protocols...
Страница 139: ...show controller statistics 139 See also reset all statistics reset controller statistics...
Страница 153: ...show disk statistics 153 See also reset all statistics reset disk error statistics reset disk statistics show disks...
Страница 162: ...162 Alphabetical list of commands See also show power supplies...
Страница 207: ...show volume reservations 207 Basetypes volume reservations status See also release volume show volumes...