190 Alphabetical list of commands

Other MC Status

The operational status of the Management Controller in the partner controller. This is not factored 

into system health.

Operational

Not Operational

Not Communicating

Unknown

PFU Status

Shows whether partner firmware update is running on the system, or is idle.

Supported Locales

Supported display languages: English, Spanish, French, German, Italian, Japanese, Dutch, 

Chinese-Simplified, Chinese-Traditional, Korean.

Example

Show information about the system.

# show system

Basetypes •

system

unhealthy-component

status

See also •

set system

show system-parameters

Содержание AssuredSAN 6004

Страница 1: ...nce Guide For firmware release GF101 or later P N 83 00006818 1 1 01 Revision A May 2015 Abstract This guide provides information about managing a Dot Hill AssuredSAN 6004 storage system by using its...

Страница 2: ...ll other trademarks and registered trademarks are proprietary to their respective owners The material in this document is for information only and is subject to change without notice While reasonable...

Страница 3: ...Specifying initiators and hosts 20 Specifying fan modules 20 User password rules 20 Command completion editing and history 21 Viewing help 21 Size representations 21 Event log 22 2 Categorical list of...

Страница 4: ...stics 77 restart mc 78 restart sc 79 restore defaults 80 scrub vdisk 81 scrub volume 82 set advanced settings 83 set auto write through trigger Deprecated 87 set awt Deprecated 87 set cache parameters...

Страница 5: ...parameters 154 show enclosures 155 show events 157 show expander status 159 show fans 161 show frus 163 show host maps Deprecated 164 show host parameters Deprecated 164 show host phy statistics 165...

Страница 6: ...230 cli parameters 231 code load readiness 234 code load readiness reasons 235 compact flash 236 controller cache parameters 237 controllers 239 controller statistics 243 debug log parameters 245 degr...

Страница 7: ...atus 313 shutdown status 314 snmp parameters 315 status 316 syslog parameters 317 system 318 system parameters table 320 tasks 323 time settings table 324 unhealthy component 325 unwritable cache 327...

Страница 8: ...ics properties 251 23 disk statistics properties 253 24 drawer sensors properties 255 25 drawers properties 257 26 drive parameters properties 259 27 drive summary properties 260 28 drives properties...

Страница 9: ...ies 320 67 tasks properties 323 68 time settings table properties 324 69 unhealthy component properties 325 70 unwritable cache properties 327 71 users properties 328 72 vdisk hist statistics properti...

Страница 10: ...mbols CAUTION Indicates that failure to follow directions could result in damage to equipment or data IMPORTANT Provides clarifying information or specific instructions NOTE Provides additional inform...

Страница 11: ...Document conventions and symbols 11 TIP Provides helpful hints and shortcuts...

Страница 12: ...CI Console format enables users to interact with the CLI and obtain easily readable information This format automatically sizes fields according to content and adjusts content to window resizes These...

Страница 13: ...0001 dg0001_v0001 100 7GB 100 7GB Linear standard OK Success Command completed successfully 2014 07 10 13 43 36 exit Using a script to access the CLI The following example shows how to construct a Per...

Страница 14: ...minate scripts must use an expect type mechanism to scan output for prompts It is more efficient to use the HTTP interface to access the XML API The following example shows how to construct a Perl scr...

Страница 15: ...in the system url http 10 0 0 2 api show disks req HTTP Request new GET url req header sessionKey sessionKey req header dataType ipa res ua request req url2 http 10 0 0 2 api exit req2 HTTP Request n...

Страница 16: ...te allows output in brief mode to be correlated with metadata to reduce the overhead of each command as described in XML API optimization This is also a good field to use to detect the type of the obj...

Страница 17: ...15 draw false sort nosort display name Return Code 0 PROPERTY PROPERTY name component id type string size 80 draw false sort nosort display name Component ID PROPERTY PROPERTY name time stamp type st...

Страница 18: ...OPERTY PROPERTY name controller numeric key true type string 1 PROPERTY PROPERTY name port key true type string A0 PROPERTY PROPERTY name health recommendation type string PROPERTY OBJECT basetype sas...

Страница 19: ...by colons with no spaces RAID 50 example 1 1 3 1 4 6 1 7 1 10 11 Specifying vdisks You can specify A vdisk by its name or serial number A unique serial number is automatically assigned when a vdisk i...

Страница 20: ...1 Specifying initiators and hosts You can specify A SAS initiator by its nickname or 16 hex digit WWPN A host by name in the format host name where represents all initiators in the host Example Mail_S...

Страница 21: ...s enter help To view full help for a command name enter help command name To view the information shown in Command syntax above enter help syntax To view the information shown in this topic and in Com...

Страница 22: ...t may affect system stability but not data integrity Evaluate the problem and correct it if necessary Informational A configuration or state change occurred or a problem occurred that the system corre...

Страница 23: ...t syslog parameters show email parameters show events show snmp parameters show syslog parameters test System configuration and utilities check firmware upgrade health clear cache create certificate p...

Страница 24: ...otes about its usage Min role The minimum user role required to use the command Syntax The command s syntax Parameters Descriptions of the command s parameters Output Descriptions of fields shown in c...

Страница 25: ...separated list of the names or serial numbers of the vdisks to stop scrubbing A name that includes a space must be enclosed in double quotes volume volumes Optional A comma separated list of the names...

Страница 26: ...n of specified disk groups or vdisks Min role manage Syntax abort verify vdisk vdisks Parameters vdisk vdisks Optional A comma separated list of the names or serial numbers of the vdisks to stop verif...

Страница 27: ...A dedicated spare is assigned to a fault tolerant vdisk with the same disk type A vdisk can have 4 dedicated spares Min role manage Syntax add spares vdisk vdisk disks Parameters vdisk vdisk Optional...

Страница 28: ...nditions that are detected are listed with their potential risks You can use commands in the See also section to determine which components have health problems to be resolved Min role manage Syntax c...

Страница 29: ...rs indicate a critical temperature Code load failure At least one controller contains unwritten cache data Data corruption data loss One or more supercapacitors have failed Code load failure One or mo...

Страница 30: ...CAUTION Only use this command when all disk groups are online Improper use of this command may result in data loss You can clear unwritable cache data for a specified volume or for all volumes Min ro...

Страница 31: ...d is run error counts used to measure disk medium errors are restarted Min role manage Syntax clear degraded disk disks Parameters disks The IDs of the disks to operate on For disk syntax see Command...

Страница 32: ...The disk s health becomes Degraded and its How Used state becomes LEFTOVR The disk is automatically excluded from the vdisk causing the vdisk s health to become Degraded or Fault depending on the RAID...

Страница 33: ...se by or with direction from technical support Min role manage Syntax clear events a b both Parameters a b both Optional The controller event log to clear If this parameter is omitted both event logs...

Страница 34: ...tatus command NOTE If a rescan is in progress the clear operation will fail with an error message saying that an EMP does exist Wait for the rescan to complete and then retry the clear operation Min r...

Страница 35: ...and can include printable UTF 8 characters except space or semicolon An example is CO US ST CO O MyOrganization CN www mysite com You must specify either this parameter or the restore parameter or the...

Страница 36: ...ursday Friday Saturday of year month January February March April May June July August September October November December Constrains the days or months when the task is permitted to run Ensure that t...

Страница 37: ...e first time on March 1 2014 and on the first weekday of each month with no expiration create schedule schedule specification start 2012 03 01 00 01 only first weekday of month task name Task2 Sched2...

Страница 38: ...for all disks You can use this to disable or suspend spin down during hours of frequent activity name A name for the new task Input rules The value is case sensitive The value can have a maximum of 3...

Страница 39: ...renheit f timeout trap host IP address type novice standard advanced diagnostic units auto MB GB TB name Parameters authentication type MD5 SHA none Optional For an SNMPv3 user this specifies whether...

Страница 40: ...able ASCII characters must include at least one uppercase character one lowercase character and one non alphabetic character If this parameter is omitted the command prompts you to enter and re enter...

Страница 41: ...t that will receive SNMP traps type novice standard advanced diagnostic Optional Identifies the user s experience level This parameter is informational only and does not affect access to commands The...

Страница 42: ...4 authentication type SHA privacy type AES privacy password Abcd5678 MIB Create user Traps that can receive SNMP trap notifications using authentication without encryption create user interfaces snmpt...

Страница 43: ...ber before moving to the next member of the vdisk For RAID 50 this option sets the chunk size of each RAID 5 subvdisk The chunk size of the RAID 50 vdisk is calculated as configured chunk size x subvd...

Страница 44: ...aces and printable UTF 8 characters except A value that includes a space must be enclosed in double quotes Example Create the RAID 1 vdisk VD1 using two disks in the first enclosure create vdisk level...

Страница 45: ...n to the mapping on all ports ports ports Optional The ports through which the host can access the volume All specified ports must be the same type For port syntax see Command syntax page 18 If this p...

Страница 46: ...46 Alphabetical list of commands See also create volume set delete volumes set volume show ports show vdisks show volumes...

Страница 47: ...ed by the ports parameter If the baselun and ports parameters are omitted the volumes are not mapped If a LUN to be assigned to a volume is already in use an error message is displayed and that volume...

Страница 48: ...that size Any larger value will be rounded down to the next multiple of that size The maximum volume size is 140 TB 128 TiB vdisk vdisk Optional required for linear volumes The name or serial number...

Страница 49: ...ckname of a discovered initiator commands will show the initiator by its ID Min role manage Syntax delete initiator nickname initiators Parameters initiators A comma separated list of the nicknames or...

Страница 50: ...age Syntax delete schedule prompt yes no schedule Parameters prompt yes no Optional For scripting this specifies whether to automatically reply yes or no to confirmation prompts If this parameter is o...

Страница 51: ...es no Optional For scripting this specifies whether to automatically reply yes or no to confirmation prompts If this parameter is omitted you must manually reply to confirmation prompts task The name...

Страница 52: ...Min role manage Syntax delete user noprompt name Parameters noprompt Optional in console format required for XML API format Suppresses the confirmation prompt which requires a yes or no response Spec...

Страница 53: ...ax delete vdisks prompt yes no vdisks Parameters prompt yes no Optional For scripting this specifies an automatic reply to the confirmation prompt that appears if a utility is running on the vdisk yes...

Страница 54: ...ta it contains and its schedules Min role manage Syntax delete volumes volumes Parameters volumes A comma separated list of the names or serial numbers of the volumes to delete A name that includes a...

Страница 55: ...n inaccessible disk event 172 is logged If quarantine occurs to prevent writing invalid data event 485 is logged For recommended actions for these events see the Event Descriptions Reference Guide Exa...

Страница 56: ...the event s recommended action text If event 485 was logged use the dequarantine command only as specified by the event s recommended action text to avoid data corruption or loss When a disk group is...

Страница 57: ...D1 QTDN RAID 6 quarantined with a down disk dequarantine vdisk VD1 Info Vdisk VD1 was dequarantined VD1 Success Command completed successfully 2013 08 01 14 06 09 show vdisks Name Status VD1 FTDN RAID...

Страница 58: ...58 Alphabetical list of commands exit Description Log off and exit the CLI session Min role monitor Syntax exit...

Страница 59: ...add 2 or 4 disks at a time Can expand the vdisk one RAID 5 sub vdisk at a time The added RAID 5 sub vdisk must contain the same number of disks as each original sub vdisk 1 16 2 16 32 IMPORTANT Vdisk...

Страница 60: ...10 vdisk R10 to include an additional mirror pair expand vdisk disks 2 9 10 R10 Expand RAID 50 vdisk R50 which has four 3 disk sub vdisks to include an additional 3 disk sub vdisk expand vdisk disks 2...

Страница 61: ...pand volume size size B KB MB GB TB KiB MiB GiB TiB max volume Parameters size size B KB MB GB TB KiB MiB GiB TiB Specifies either The amount of space to add the volume The unit is optional B represen...

Страница 62: ...formation that is only available via a crash dump CAUTION Do not use this command in a production system Use only for testing This command will interfere with the operation of volumes in vdisks owned...

Страница 63: ...mapping read write rw read only ro or no access If the access parameter is specified as read write or read only the lun parameter must be specified For an explicit mapping no access causes the volume...

Страница 64: ...or Init1 v2 Map volumes v2 and v3 with read write access for Init2 using ports A1 and B1 and LUN 101 map volume access rw ports a1 b1 lun 101 initiator Init2 v2 v3 Mask volume v4 from Init1 and Init3...

Страница 65: ...ta basetypes Parameters basetypes A basetype or a list of basetypes separated by commas with no spaces to specify the objects for which to show metadata For names and descriptions of supported basetyp...

Страница 66: ...its for replies Min role monitor Syntax ping host address count Parameters host address The remote host s IP address in dotted decimal form count Optional The number of packets to send The default is...

Страница 67: ...to a clean state CAUTION Releasing reservations for volumes may allow unintended access to those volumes by other initiators which may result in data corruption Before issuing this command quiesce all...

Страница 68: ...s linear storage only in the same command Min role manage Syntax remove spares disks Parameters disks The IDs of the spares to remove For disk syntax see Command syntax page 18 Example Remove dedicate...

Страница 69: ...en resumes normal operation It can take up to two minutes for the enclosure IDs to be corrected A manual rescan may be needed after system power up to display enclosures in the proper order Whenever y...

Страница 70: ...ipting this specifies an automatic reply to the confirmation prompt that will appear if the historical parameter is specified yes Allow the command to proceed no Cancel the command If the historical p...

Страница 71: ...reset controller statistics a b both Parameters a b both Optional Specifies whether to reset statistics for controller A B or both If this parameter is omitted statistics are reset for both controller...

Страница 72: ...he disk and not categorized as media errors Number of block reassignments Number of bad blocks found To reset other disk statistics use the reset disk statistics command Min role manage Syntax reset d...

Страница 73: ...r statistics To reset these use the reset disk error statistics command Min role manage Syntax reset disk statistics Example Reset statistics for all disks reset disk statistics See also reset all sta...

Страница 74: ...es a COMINIT COMRESET sequence and might reset other ports Min role manage Syntax reset host link ports ports Parameters ports ports A controller host port ID a comma separated list of IDs a hyphenate...

Страница 75: ...t number of ports for which to reset statistics For port syntax see Command syntax page 18 If this parameter is omitted statistics are reset for all controller host ports Example Reset statistics for...

Страница 76: ...e names or serial numbers of the vdisks for which to reset statistics A name that includes a space must be enclosed in double quotes If this parameter is omitted statistics are reset for all vdisks Ex...

Страница 77: ...mbers of the volumes for which to reset statistics A name that includes a space must be enclosed in double quotes If this parameter is omitted statistics are reset for all volumes Example Reset statis...

Страница 78: ...rt If this parameter is omitted the command affects the controller being accessed noprompt Optional in console format required for XML API format Suppresses the confirmation prompt which requires a ye...

Страница 79: ...information see help for commands that show statistics Min role manage Syntax restart sc a b both noprompt Parameters a b both Optional The controller module containing the controller to restart If t...

Страница 80: ...store defaults noprompt prompt yes no Parameters noprompt Optional in console format required for XML API format Suppresses the confirmation prompt which requires a yes or no response Specifying this...

Страница 81: ...round scrub enabled with the set advanced settings command You can use a vdisk while it is being scrubbed To check the progress of a vdisk scrub VRSC job use the show vdisks command When a vdisk scrub...

Страница 82: ...ng scrubbed To check the progress of a volume scrub job use the show volumes command NOTE Only one scrub operation can be running on a vdisk at a time If a manual scrub is started while a background s...

Страница 83: ...nd recovers the system so that at least one controller is operational thus avoiding data unavailability situations This feature focuses on Active Active I O stalls and failover recovery stalls When a...

Страница 84: ...rough when a controller fails disabled or off The controller failure trigger is disabled This is the default enabled or on The controller failure trigger is enabled dynamic spares enabled disabled on...

Страница 85: ...equest is illegal Sense data returned is sensekey 5 code 25h qualifier 0 partner firmware upgrade enabled disabled on off Optional Sets whether component firmware versions are monitored and will be au...

Страница 86: ...back to write through when the supercapacitor that provides backup power for cache is not fully charged or fails disabled or off The supercapacitor failure trigger is disabled enabled or on The superc...

Страница 87: ...Use set advanced settings Example Enable partner firmware upgrade set advanced settings partner firmware upgrade enabled Enable managed logs set advanced settings managed logs enabled Enable auto sta...

Страница 88: ...reverse decreasing LBAs Increasing the read ahead size can greatly improve performance for multiple sequential read streams However increasing read ahead size will likely decrease random read performa...

Страница 89: ...nge A name that includes a space must be enclosed in double quotes Example Set the cache policy optimization mode and read ahead size for volume V1 set cache parameters write policy wb optimization st...

Страница 90: ...pecify a base 2 or base 10 size unit the resulting size will be in base 2 10 Sizes are shown as powers of 10 using 1000 as a divisor for each magnitude This is the default In base 10 when you set a si...

Страница 91: ...This is the default timeout Optional Sets the timeout value in seconds for the login session Valid values are 120 43200 seconds 2 720 minutes The default is 1800 seconds 30 minutes units auto MB GB TB...

Страница 92: ...ate and time manually by specifying a timestamp set controller date timestamp timestamp timezone hh mm To configure use of NTP set controller date ntp enabled disabled on off ntpaddress IP address tim...

Страница 93: ...sep 22 13 45 0 2011 Manually set the system date and time to 4 30 50 PM on November 2 201 1 by specifying a timestamp and an offset for the Central Time zone set controller date timestamp 1320273050...

Страница 94: ...s Enabled by default fruid FRU ID debug messages Enabled by default hb Not used host Host interface debug messages Enabled by default init Not used ioa I O interface driver debug messages standard Ena...

Страница 95: ...tional severity warning Generate an event with Warning severity none Do not generate an event disk error policy fail none Optional Specifies the action to take when a disk is determined to be degraded...

Страница 96: ...accumulates errors before a threshold value is set and the newly set value has already been reached an event will not be logged until the next time that threshold is reached Changing a threshold afte...

Страница 97: ...ot differentiated by disk tier RAID redundancy levels are defined as single Disks used in a RAID type other than RAID 6 dual Disks used in RAID 6 target recoverable errors unrecoverable errors Specifi...

Страница 98: ...ix unrecoverable errors over the period of the next two days and degrade an archive disk should it incur seven unrecoverable errors over the period of one week set degraded disk threshold name archive...

Страница 99: ...rs smart enabled disabled on off detect only Optional Sets whether SMART is enabled or disabled for disks disabled or off Disables SMART for all disks in the system and for all disks added to the syst...

Страница 100: ...ogs email notifications that are sent to the log collection system This option is disabled by default notification level crit error warn info none The minimum severity for which the system should send...

Страница 101: ...ics are 2 bytes and most Asian characters are 3 bytes The value can include spaces and printable UTF 8 characters except A value that includes a space must be enclosed in double quotes location locati...

Страница 102: ...ilure occurs Min role manage Syntax set expander fault isolation controller a b both enabled disabled on off encl enclosure ID wwn enclosure wwn Parameters controller a b both Optional The I O module...

Страница 103: ...the wwn parameter phy phy ID The logical PHY number type drive inter exp sc sc 0 sc 1 sca p scb p sca a scb a ingress expander ingress 0 expander ingress 1 egress expander egress 0 expander egress 1 d...

Страница 104: ...re containing the PHY Specify either this parameter or the encl parameter Example Disable the first egress PHY in controller A set expander phy encl 0 controller a type egress phy 0 disabled Enable th...

Страница 105: ...e name Optional Sets the name of the initiator to the specified name Input rules The value is case sensitive The value can have a maximum of bytes where ASCII characters are 1 byte most Latin Western...

Страница 106: ...t locator LED on the I O module and on the enclosure s right ear disk ID Specifies the disk to locate For disk syntax see Command syntax page 18 This affects the fault LED drawer ID Specifies the draw...

Страница 107: ...set led 107 Identify drawer 1 in enclosure 1 set led drawer 1 1 on Identify fan 1 in enclosure 1 set led fan 1 1 on...

Страница 108: ...e not routable This prevents the DHCP server from reassigning the addresses and possibly causing a conflict where two controllers have the same IP address As soon as possible change these IP values to...

Страница 109: ...ing broadcast enabled disabled on off Optional Enables the storage system to respond when a ping to a broadcast address is issued on the system s subnet The default is Disabled Example Use DHCP to set...

Страница 110: ...ess Optional The network address of an available NTP server timezone hh mm Optional The system s time zone as an offset in hours 12 through 14 and optionally minutes 00 59 from Coordinated Universal T...

Страница 111: ...ASCII characters must include at least one uppercase character one lowercase character and one non alphabetic character If this parameter is omitted the command prompts you to enter and re enter a va...

Страница 112: ...pt Parameters prompt The new prompt Input rules The value is case sensitive The value can have a maximum of 16 characters The value can include printable UTF 8 characters except A value that includes...

Страница 113: ...rivileged diagnostic user IDs This is disabled by default ftp enabled disabled on off Optional Enables or disables the expert interface for updating firmware This is enabled by default http enabled di...

Страница 114: ...114 Alphabetical list of commands See also set cli parameters show protocols...

Страница 115: ...m AM PM and hh mm AM PM Constrains the time range during which the task is permitted to run Ensure that the start time is within the specified time range only any first second third fourth fifth last...

Страница 116: ...re disabled read community string Optional Sets a community string for read only access Input rules The value is case sensitive The value can have a maximum of 31 bytes where ASCII characters are 1 by...

Страница 117: ...l is other than none host ip must be specified host port port number Optional A specific port number on the host notification level crit error warn info none The minimum severity for which the system...

Страница 118: ...pean characters with diacritics are 2 bytes and most Asian characters are 3 bytes The value can include spaces and printable UTF 8 characters except A value that includes a space must be enclosed in d...

Страница 119: ...timeout trap host IP address type novice standard advanced diagnostic units auto MB GB TB name Parameters authentication type MD5 SHA none Optional For an SNMPv3 user this specifies whether to use a s...

Страница 120: ...his specifies the authentication password precision Optional Sets the number of decimal places 1 10 for display of storage space sizes The default is 1 privacy password encryption password Optional Fo...

Страница 121: ...d diagnostic Optional Identifies the user s experience level This parameter is informational only and does not affect access to commands The default is standard units auto MB GB TB Optional Sets the u...

Страница 122: ...t supported and may cause data loss or unavailability All volumes in the vdisk must be unmapped or attached hosts must be shut down before the ownership of a vdisk is changed spin down delay delay Opt...

Страница 123: ...e value can include spaces and printable UTF 8 characters except A value that includes a space must be enclosed in double quotes name new name Optional A new name for the volume Input rules The value...

Страница 124: ...s This does not affect vdisk background scrub which always runs at background priority High Utilities have higher priority than host I O This can cause heavy I O to be slower than normal This is the d...

Страница 125: ...eady Sends a reply that there is a LUN where a gap has been created but that it s not ready Sense data returned is sensekey 2 code 4 qualifier 3 This is the default Illegal Request Sends a reply that...

Страница 126: ...his is the default Enabled Drive spin down for available disks and global spares is enabled Inactive Drive Spin Down Delay Shows the period of inactivity in minutes after which available disks and glo...

Страница 127: ...avoiding data unavailability situations This feature focuses on Active Active I O stalls and failover recovery stalls When a stall is detected event 531 is logged Disabled Auto stall recovery is disab...

Страница 128: ...Unified LUN Presentation Data for volumes configured to use write back cache is automatically mirrored between the two controllers to provide fault tolerance Single Controller There is only a single...

Страница 129: ...is specified its cache optimization mode standard Optimizes cache for both sequential and random reads Appropriate for applications that read and write small files in random order such as transaction...

Страница 130: ...ut Certificate Status Customer supplied The controller is using a certificate that you have uploaded System generated The controller is using system generated certificates Unknown status The controlle...

Страница 131: ...is is the default Base The base for entry and display of storage space sizes 2 Sizes are shown as powers of 2 using 1024 as a divisor for each magnitude 10 Sizes are shown as powers of 10 using 1000 a...

Страница 132: ...atures are shown in degrees Fahrenheit Celsius Temperatures are shown in degrees Celsius This is the default Management Mode Not applicable Example Show current CLI settings show cli parameters Basety...

Страница 133: ...information from show controllers Controller firmware and hardware version information from show versions with the detail parameter Host and expansion port information from show ports Disk information...

Страница 134: ...te Date and time in the format year month day hour minutes seconds Time Zone Offset The system s time zone as an offset in hours and minutes from Coordinated Universal Time UTC This is shown only if N...

Страница 135: ...C Address Controller network port MAC address WWNN Storage system World Wide Node Name WWNN IP Address Controller network port IP address IP Subnet Mask Controller network port IP subnet mask IP Gatew...

Страница 136: ...the controller in the enclosure Top The controller is in the top slot Bottom The controller is in the bottom slot Phy Isolation Shows whether the automatic disabling of SAS expander PHYs having high e...

Страница 137: ...trollers are operational Operational but not redundant In active active mode one controller is operational and the other is offline In single controller mode the controller is operational Down This co...

Страница 138: ...nterval since these statistics were last requested or reset This value will be zero if it has not been requested or reset since a controller restart Reads The number of read operations since these sta...

Страница 139: ...show controller statistics 139 See also reset all statistics reset controller statistics...

Страница 140: ...driver debug messages lower layer verbose Disabled by default misc Internal debug messages Enabled by default rcm Removable component manager debug messages Disabled by default raid RAID debug messag...

Страница 141: ...k Error Notification Informational Generate an event with Informational severity Warning Generate an event with Warning severity None Do not generate an event Disk Error Action Fail Fail the disk None...

Страница 142: ...e Performance tier any RAID level all single All disks single redundancy RAID all dual All disks dual redundancy RAID all All disks any RAID level Disk tiers are defined as archive Disks with rotation...

Страница 143: ...A numeric value for the threshold count Threshold is not set Example Show information for all threshold names show degraded disk thresholds Show information for threshold name archive single only show...

Страница 144: ...um Maximum number of times a timed out I O operation can be retried before the operation is failed Attempt Timeout Number of seconds before an I O operation is aborted and possibly retried Overall Tim...

Страница 145: ...pecified disks this parameter shows performance statistics from the latest historical sample for each disk Statistics shown include total I Os reads and writes total amount of data transferred and ave...

Страница 146: ...average time in microseconds to complete I O Jobs Shown by default DRSC The disk is being scrubbed EXPD The disk group is being expanded INIT The disk group is being initialized RCON The disk group is...

Страница 147: ...rough the second port to the other controller blank The disk is operating normally Size Shown by default and by any parameter except temp The disk capacity formatted to use the current base precision...

Страница 148: ...Critical The disk sensor detected a critical error condition The temperature currently exceeds the critical threshold Unknown The disk sensor is present but status is not available Total I Os Shown b...

Страница 149: ...on show disks encl Show disk performance statistics show disks perf Show disk temperature information show disks temp Show detailed information for disk 1 1 show disks 1 1 detail Basetypes drives encl...

Страница 150: ...ata samples to display from 1 to 100 Each sample will be shown as a separate row in the command output If this parameter is omitted 100 samples will be shown If you specify this parameter do not speci...

Страница 151: ...inutes seconds when these statistics were last reset either by a user or by a controller restart Output Historical Durable ID The disk ID in the form disk_enclosure number disk number Serial Number Th...

Страница 152: ...Shown by the all parameter The average data size of read operations since the last sampling time Average Write I O Size Shown by the all parameter The average data size of write operations since the l...

Страница 153: ...show disk statistics 153 See also reset all statistics reset disk error statistics reset disk statistics show disks...

Страница 154: ...lt This parameter does not apply to managed logs notifications Email Address 1 3 Shows up to three email addresses for recipients of event notifications Log Destination Shows the email address for the...

Страница 155: ...enclosure vendor Model The enclosure model EMP controller ID BUS ID Rev The channel ID and firmware revision of the Enclosure Management Processor in each controller s Expander Controller Midplane Ty...

Страница 156: ...rawer Up Warning Error Unknown Unavailable Not Present Health OK Degraded Fault N A Unknown Reason If Health is not OK this field shows the reason for the health state Action If Health is not OK this...

Страница 157: ...ts from both controllers Do not use this parameter with the from event parameter or the to event parameter error Shows Warning Error and Critical events detail Optional Shows additional information an...

Страница 158: ...dule that logged the event Severity CRITICAL A failure occurred that may cause a controller to shut down Correct the problem immediately ERROR A failure occurred that may affect data integrity or syst...

Страница 159: ...Egress Drawer 0 egress PHY Drawer0 Ingress Drawer 0 ingress PHY Drawer1 Egress Drawer 1 egress PHY Drawer1 Ingress Drawer 1 drawer ingress PHY Drive Drive slot PHY Egress Expansion port egress PHY Ex...

Страница 160: ...into operation Disabled Enabled PHY is enabled Disabled PHY is disabled Reason Blank if Elem Status is OK Error count interrupts PHY disabled because of error count interrupts Phy control PHY disabled...

Страница 161: ...Status Up Error Off Missing Speed The fan speed revolutions per minute Position The fan position as viewed from the back of the enclosure Left Right Serial Number blank Not applicable Firmware Versio...

Страница 162: ...162 Alphabetical list of commands See also show power supplies...

Страница 163: ...losure disk drawer Description The FRU description Part Number The FRU part number Serial Number The FRU serial number Revision The hardware revision level Dash Level The FRU template revision number...

Страница 164: ...he left as viewed from the back RIGHT FAN SLOT Fan module on the right as viewed from the back LEFT DRAWER SLOT Drawer on the left as viewed from the front RIGHT DRAWER SLOT Drawer on the right as vie...

Страница 165: ...rt number of the SAS host ports for which PHY statistics are displayed Phy Identifies a PHY s logical location within a group based on the PHY type Logical IDs are 0 3 for host port PHYs Each SAS host...

Страница 166: ...tics were last requested or reset This value will be zero if it has not been requested or reset since a controller restart Reads The number of read operations since these statistics were last reset or...

Страница 167: ...w hosts Deprecated Use show initiators Show live performance statistics for host port A1 show host port statistics ports a1 Basetypes host port statistics status See also reset all statistics reset ho...

Страница 168: ...a name for the initiator Syntax show initiators initiators Parameters initiators Optional A comma separated list of the names of initiators for which to show information If this parameter is omitted i...

Страница 169: ...ry Output Product vendor name product ID and vendor ID Management Controller firmware version and loader version Storage Controller firmware version and loader version Controller module serial number...

Страница 170: ...this parameter is omitted mapping information is shown by volume IDs Optional A comma separated list of the names or serial numbers of initiators or volumes for which to show mappings Do not include...

Страница 171: ...apped as no access Serial Number The serial number of the volume Example Show mappings for all volumes show maps Show mapping information for all initiators show maps initiator Basetypes initiator vie...

Страница 172: ...Link Speed Unknown For a system operating in Single Controller mode this controller module is not present 10mbps The network port link speed is set to 10 Mb s 100mbps The network port link speed is se...

Страница 173: ...ress The current NTP server IP address if NTP is enabled The last set NTP server IP address if NTP was enabled and has been disabled 0 0 0 0 if the NTP server IP address has not been set Last Server C...

Страница 174: ...eed A Actual link speed in Gbit s Blank if not applicable Speed C Configured host port link speed Not shown for SAS Blank if not applicable Health OK Degraded Fault N A Unknown Reason If Health is not...

Страница 175: ...how ports 175 Example Show information about host ports in each controller module show ports Show detailed information about host ports in each controller module show ports detail Basetypes port statu...

Страница 176: ...power supply identifier and location Firmware Version blank Not applicable The firmware revision of the power supply Health OK Degraded Fault N A Unknown Reason If Health is not OK this field shows th...

Страница 177: ...SNMP interface is enabled or disabled When this is disabled all SNMP requests to the MIB are disabled and SNMP traps are disabled The default is Enabled Service Debug Shows whether the Telnet debug po...

Страница 178: ...he command output to find the associated controller and disks Min role monitor Syntax show provisioning disks disks luns LUNs ports ports vdisks vdisks volumes volumes no mapping unhealthy Parameters...

Страница 179: ...pping information Yes The volume is mapped No The volume is not mapped Mapping information Ports Controller host ports that the mapping applies to Blank if not mapped or mapped as no access LUN LUN th...

Страница 180: ...ovisioning for the system show provisioning Show provisioning for vdisk myR1 show provisioning vdisks myR1 Show provisioning for all unhealthy vdisks show provisioning unhealthy Basetypes provisioning...

Страница 181: ...e its partner is not operational The system has lost redundancy Down Both controllers are not operational Controller Redundancy Status Redundant with independent cache Both controllers are operational...

Страница 182: ...ted The value 0 means the data has never been updated and is not cached A value other than 0 is a timestamp indicating that the data has been updated If the value has changed since the last time you c...

Страница 183: ...ted to an egress expansion port in a controller module or an expansion module Status Up The port is cabled and has an I O link Warning Not all of the port s PHYs are up Error The port is reporting an...

Страница 184: ...cheduled time Suspended The task had an error and is holding in its current state Expired The task exceeded a constraint and will not run again Invalid The task is invalid Deleted The task has been de...

Страница 185: ...its value For Overall Unit Status one of the status values below Status OK The sensor is present and detects no error condition Warning The sensor detected a non critical error condition Temperature...

Страница 186: ...ot installed Controller B up active down shut down or killed not installed Other MC Status The operational status of the Management Controller in the partner controller This is not factored into syste...

Страница 187: ...traps and traps are disabled SNMP Trap Host IP The IP address of each trap host SNMP read community The community string for read only access The value is obscured for users having only the monitor ro...

Страница 188: ...h the system sends notifications crit Sends notifications for Critical events only error Sends notifications for Error and Critical events warn Sends notifications for Warning Error and Critical event...

Страница 189: ...ninitialized Contact System Location The location of the system The default is Uninitialized Location System Information A brief description of what the system is used for or how it is configured The...

Страница 190: ...Not Communicating Unknown PFU Status Shows whether partner firmware update is running on the system or is idle Supported Locales Supported display languages English Spanish French German Italian Japan...

Страница 191: ...cache redundancy mode is shown as Active Active ULP ULP uses the T10 Technical Committee of INCITS Asymmetric Logical Unit Access ALUA extensions in SPC 3 to negotiate paths with aware host systems U...

Страница 192: ...he task is complete Deleted The task has been deleted Task State The current step of the task which is always Start Error Message If an error occurred while processing the task the error message Blank...

Страница 193: ...ow tasks 193 Example Show information about all tasks show tasks Show information about task Task1 show tasks Task1 Basetypes tasks status See also create schedule create task delete task show schedul...

Страница 194: ...s disks must be brought online If the data is not needed it can be cleared in which case it will be lost and data will differ between the host and disk Min role monitor Syntax show unwritable cache Ou...

Страница 195: ...and change system settings diagnostic The user can view and change system settings User Type The user s experience level Novice Standard Advanced or Diagnostic This parameter does not affect access to...

Страница 196: ...Privacy Password The encryption password for an SNMPv3 user whose privacy type is set to DES or AES Trap Host Address SNMP trap destination for an SNMPv3 user that can receive trap notifications Exam...

Страница 197: ...r the partner controller when the preferred owner is offline Pref The controller that owns the vdisk and its volumes during normal operation RAID The vdisk RAID level Class Linear The vdisk acts as a...

Страница 198: ...ine or if after 60 seconds from being quarantined the vdisk is QTCR or QTDN the vdisk is automatically dequarantined QTOF Quarantined offline The vdisk is offline with multiple inaccessible disks caus...

Страница 199: ...e health state Action If Health is not OK this field shows recommended actions to take to resolve the health issue Example Show information about all vdisks show vdisks Show information about vdisk vd...

Страница 200: ...n live output This is caused by a difference in the way that historical and live values are calculated Live values are calculated based on the vdisk as viewed from the controller cache perspective In...

Страница 201: ...t Live Name The vdisk name Serial Number The vdisk serial number Bytes per second The data transfer rate calculated over the interval since these statistics were last requested or reset This value wil...

Страница 202: ...data read since the last sampling time Data Written Shown by the all parameter The amount of data written since the last sampling time Total B s The data transfer rate in bytes per second since the la...

Страница 203: ...show vdisk statistics 203 Basetypes vdisk statistics live virtual disk summary historical vdisk hist statistics historical status See also reset all statistics reset vdisk statistics show vdisks...

Страница 204: ...rsions detail Parameters detail Optional Shows information about the versions of firmware and hardware in each controller module If this parameter is omitted only firmware bundle information is shown...

Страница 205: ...es or serial numbers of the volumes for which to show information A name that includes a space must be enclosed in double quotes If this parameter is omitted information is shown for all volumes Outpu...

Страница 206: ...space must be enclosed in double quotes Output Name The name of the volume Serial Number The serial number of the volume Volume Reserved Free The volume is not reserved Reserved The volume has been r...

Страница 207: ...show volume reservations 207 Basetypes volume reservations status See also release volume show volumes...

Страница 208: ...ch to show information A name that includes a space must be enclosed in double quotes Output Properties are described in alphabetical order Action If Health is not OK this field shows recommended acti...

Страница 209: ...tandard Standard volume Vdisk The name of the vdisk that contains the volume WR Policy Shown by the details parameter The cache write policy write back Write back caching does not wait for data to be...

Страница 210: ...or reset This value will be zero if it has not been requested or reset since a controller restart IOPS The input output operations per second calculated over the interval since these statistics were l...

Страница 211: ...ule is shut down hosts cannot access the system s data Perform a shut down before removing a controller module or powering down the system Min role manage Syntax shutdown a b both Parameters a b both...

Страница 212: ...vailable When a drawer is successfully restarted the health will change to OK and the status to Up and event 526 will be logged Use the show enclosures command and event log to determine when a drawer...

Страница 213: ...wer the availability and or health of the vdisk may be affected To avoid data loss quiesce I O to volumes on vdisks in the drawer Min role manage Syntax stop drawer prompt yes no drawer ID Parameters...

Страница 214: ...ification Specify this option to test receipt of event notification messages by every interface that is configured to receive them such as email and SNMP Event 312 snmp This option behaves the same as...

Страница 215: ...istance in determining if the trust operation is applicable to your situation and for assistance in performing it CAUTION 1 Do not use the trust command when the storage system is unstable For example...

Страница 216: ...p performed in step 2 7 Run verify vdisk vdisk name fix no to verify that the correct disk was used in the trust command 8 Restore original vdisk ownership 9 Re enable background scrub operations Min...

Страница 217: ...he age of the disk in the vdisk The age value starts at 1 and is incremented for all good disks in the vdisk each time there is a change in the disk configuration of the vdisk such as when a disk is d...

Страница 218: ...simulated failure performed with the fail command which requires the manage role If you attempt to unfail a controller that is operating the command will have no effect Min role manage Syntax unfail...

Страница 219: ...le manage Syntax unmap volume host hosts initiator initiators volumes Parameters host hosts Deprecated use the initiator parameter instead initiator initiators Optional A comma separated list of initi...

Страница 220: ...the show vdisks command When verification is complete event 21 is logged and specifies the number of inconsistencies found Such inconsistencies can indicate that a disk is going bad TIP Unless you wa...

Страница 221: ...etype by name This chapter excludes basetypes that are for internal use only Each basetype topic includes the following information References to CLI commands that directly use the basetype For each p...

Страница 222: ...e numeric uint32 Numeric equivalents for partner firmware upgrade values 0 Disabled 1 Enabled utility priority string Priority at which data redundancy utilities such as vdisk verify and reconstruct r...

Страница 223: ...g Shows the cache redundancy mode for a dual controller storage system Disabled Controller failover is enabled and data in a controller s write back cache is mirrored to the partner controller Enabled...

Страница 224: ...supply fails Disabled The power supply failure trigger is disabled This is the default Enabled The power supply failure trigger is enabled power supply failure numeric uint32 Numeric equivalents for...

Страница 225: ...isk defects to ensure system health The interval between background disk scrub finishing and starting again is 72 hours Disabled Background disk scrub is disabled This is the default Enabled Backgroun...

Страница 226: ...feature is enabled which detects situations where a controller stall is preventing I O operations from completing and recovers the system so that at least one controller is operational thus avoiding d...

Страница 227: ...rough 1 write back cache optimization string If a volume is specified its cache optimization mode standard Optimizes cache for both sequential and random reads Appropriate for applications that read a...

Страница 228: ...2 Numeric equivalents for read ahead size values 2 Stripe 1 Adaptive 0 Disabled 524288 512 KB 1048576 1 MB 2097152 2 MB 4194304 4 MB 8388608 8 MB 16777216 16 MB 33554432 32 MB 2147483648 Maximum Table...

Страница 229: ...rs while there is data in controller cache Active Active ULP Both controllers are active using ULP Unified LUN Presentation Data for volumes configured to use write back cache is automatically mirrore...

Страница 230: ...en installed Customer supplied A custom or alternate certificate has been installed certificate status numeric uint32 Numeric equivalents for certificate status values 0 Default 1 Customer supplied ce...

Страница 231: ...Alternate form of XML output json Alternate data interchange format output format api string console api api brief api embed api embed brief json json full output format api numeric uint32 Numeric equ...

Страница 232: ...n uint8 Number of decimal places 1 10 for display of storage space sizes The default is 1 storage size units string Unit for display of storage space sizes Auto Lets the system determine the proper un...

Страница 233: ...perience level Novice Standard the default Advanced Diagnostic user type numeric uint32 Numeric equivalents for user type values 1 Novice 2 Standard 3 Advanced 4 Diagnostic username string The logged...

Страница 234: ...Type Description overall health string Pass There are no risks to performing firmware upgrade Fail At least one condition exists that presents a risk of upgrade failure or loss of availability overall...

Страница 235: ...ame Type Description readiness reason string The condition that was detected readiness reason numeric string Numeric equivalents for readiness reason values failure risks string The problems that are...

Страница 236: ...ric uint32 Numeric equivalents for status values 0 Not Installed 1 Installed cache flush string Enabled If the controller loses power it will automatically write cache data to the CompactFlash card Ca...

Страница 237: ...ondition such as a CompactFlash failure is met the cache policy for all volumes changes to write through overriding the volume specific settings When the problem is corrected the cache policy reverts...

Страница 238: ...data to the CompactFlash card Cache flush is normally enabled but is temporarily disabled during controller shut down Disabled Cache flush is disabled cache flush numeric uint32 Numeric equivalents f...

Страница 239: ...sion uint32 Not applicable ip address string Controller network port IP address ip subnet mask string Controller network port IP subnet mask ip gateway string Controller network port gateway IP addres...

Страница 240: ...or type sc cpu speed sint32 Storage Controller processor speed internal serial number string Internal serial number of the controller cache lock string Shows whether hosts are prevented from using the...

Страница 241: ...Degraded Fault Unknown N A health numeric string Numeric equivalents for health values 0 OK 1 Degraded 2 Fault 3 Unknown 4 N A health reason string If Health is not OK the reason for the health state...

Страница 242: ...not operational The system has lost redundancy Down Both controllers are not operational redundancy mode numeric uint32 Numeric equivalents for redundancy mode values 1 Independent Cache Performance M...

Страница 243: ...hits uint64 Not applicable read cache misses uint64 Not applicable number of writes uint64 For the controller whose host ports had I O activity the number of write operations since these statistics we...

Страница 244: ...ted start sample time value stop sample time string Date and time in the format year month day hour minutes seconds when sampling stopped for the iops and bytes per second values stop sample time nume...

Страница 245: ...ory debug messages are enabled for inclusion in the Storage Controller debug log Off Disabled On Enabled mem numeric uint32 Numeric equivalents for mem values 0 Off 1 On fo string Shows whether failov...

Страница 246: ...in the Storage Controller debug log Off Disabled On Enabled iod numeric uint32 Numeric equivalents for iod values 0 Off 1 On misc string Shows whether internal debug messages are enabled for inclusion...

Страница 247: ...api numeric uint32 Numeric equivalents for capi values 0 Off 1 On mui string Shows whether internal service interface debug messages are enabled for inclusion in the Storage Controller debug log Off D...

Страница 248: ...t used dms numeric uint32 Not used fruid string Shows whether FRU ID debug messages are enabled for inclusion in the Storage Controller debug log Off Disabled On Enabled fruid numeric uint32 Numeric e...

Страница 249: ...Type Description degraded disk error notification string Shows degraded disk error information Informational Generate an event with Informational severity Warning Generate an event with Warning severi...

Страница 250: ...y errors of the target type must occur within a certain time period for a disk to be considered degraded The format is period duration threshold value where period Hour day or week duration A numeric...

Страница 251: ...iops uint64 Number of write operations per second since the last sampling time total bytes per sec uint64 Total data transfer rate in bytes per second since the last sampling time total bytes per sec...

Страница 252: ...etected since the last sampling time Error types include number of SMART events number of timeouts accessing the disk number of times the disk did not respond number of attempts by the storage system...

Страница 253: ...the controller was restarted data read numeric uint64 Unformatted data read value data written uint64 Amount of data written since these statistics were last reset or since the controller was restarte...

Страница 254: ...timeout count 2 uint32 For port 2 the number of SMART events recorded no response count 2 uint32 For port 2 the number of timeouts accessing the disk spinup retry count 2 uint32 For port 2 the number...

Страница 255: ...dition Temperature voltage or current exceeds the critical threshold Unavailable The sensor is present with no known errors but has not been turned on or set into operation because it is initializing...

Страница 256: ...trollers 20 iom 21 power supplies 22 fan 31 drawer sensor type string Temperature Voltage Current Charge Capacity Unknown Type sensor type numeric uint32 Numeric equivalents for sensor type values 0 T...

Страница 257: ...Processor EMP Sin a drawer s Expander Controller emp a rev string Firmware revision for the Enclosure Management Processor EMP A in a drawer s Expander Controller emp b busid string SCSI channel ID of...

Страница 258: ...th string OK Degraded Fault N A Unknown health numeric uint32 Numeric equivalents for health values 0 OK 1 Degraded 2 Fault 3 Unknown 4 N A health reason string If Health is not OK the reason for the...

Страница 259: ...Numeric equivalents for drive write back cache values 0 Detect Only 1 Enabled 2 Disabled drive timeout retry max uint8 Maximum number of times a timed out I O operation can be retried before the opera...

Страница 260: ...k statistics when the historical parameter is specified Table 27 drive summary properties Name Type Description durable id string Disk ID in the form disk_enclosure number disk number serial number st...

Страница 261: ...ks serial number string Disk serial number vendor string Disk vendor model string Disk model revision string Disk firmware revision level secondary channel uint32 SCSI ID assigned to this disk for the...

Страница 262: ...ror disk hardware failure or unsupported disk GLOBAL SP The disk is a global spare LEFTOVR The disk is a leftover UNUSABLE The disk cannot be used in a disk group because the system is secured because...

Страница 263: ...d property 0 Off 1 On speed uint32 Not used smart string Disabled SMART is disabled for this disk Enabled SMART is enabled for this disk smart numeric string Numeric equivalents for smart values 0 Dis...

Страница 264: ...on system performance This rate adjustment persists until the controller is restarted or power cycled transfer rate numeric uint32 For internal use only attributes string Shows which controller a sing...

Страница 265: ...lass spinning SAS disks 10k 15k RPM higher capacity storage tier numeric uint32 Numeric equivalents for storage tier values 0 N A 2 Standard 4 Archive ssd life left string 100 0 For an SSD this field...

Страница 266: ...r the temperature value temperature status string OK The disk sensor is present and detects no error condition Warning The disk sensor detected a non critical error condition The temperature is betwee...

Страница 267: ...1 Degraded 2 Fault 3 Unknown 4 N A health reason string If Health is not OK the reason for the health state health recommendation string If Health is not OK the recommended actions to take to resolve...

Страница 268: ...tifications email notification filter numeric uint32 Numeric equivalents for email notification filter values 8 crit 4 error 2 warn 1 info 0 none email notify address 1 string Up to three email addres...

Страница 269: ...location string City state province and country where the FRU was manufactured mfg vendor id string JEDEC ID global manufacturing code of the FRU manufacturer fru location string Location of the FRU...

Страница 270: ...wer OFF The FRU is powered off original serialnumber string For a power supply module the original manufacturer serial number Otherwise N A original partnumber string For a power supply module the ori...

Страница 271: ...resent but is not detected by the expander Unknown Initial status when the disk is first detected or powered on Not Present The disk slot indicates that no disk is present Unrecoverable The disk is pr...

Страница 272: ...enclosure rack position uint8 Position of the enclosure in the rack number of coolings elements uint8 Number of fan units in the enclosure number of disks uint8 Number of disk slots not installed dis...

Страница 273: ...ng Shows the state of the locator LED on an enclosure Off On locator led numeric uint32 Numeric equivalents for locator led values 0 Off 1 On drive orientation string vertical Disks are oriented verti...

Страница 274: ...not capable of using PCI Express version 2 True Enclosure is capable of using PCI Express version 2 pcie2 capable numeric uint32 Numeric equivalents for pcie2 capable values 0 False 1 True health stri...

Страница 275: ...cause a controller to shut down Correct the problem immediately ERROR A failure occurred that may affect data integrity or system stability Correct the problem as soon as possible WARNING A problem o...

Страница 276: ...o help diagnose problems severity string Event severity CRITICAL A failure occurred that may cause a controller to shut down Correct the problem immediately ERROR A failure occurred that may affect da...

Страница 277: ...ort on an expansion module Can be connected to an egress expansion port in a controller module or an expansion module name numeric uint32 2 In Port 3 Out Port status string Expander port status Up War...

Страница 278: ...ses values 0 Unsupported 1 OK 2 Critical 3 Warning 4 Unrecoverable 5 Not Installed 6 Unknown 7 Unavailable extended status uint32 A numeric value that provides additional information to supplement th...

Страница 279: ...on of a fan FRU hw revision string blank Not applicable locator led string Shows the state of the locator LED on a fan unit Off On locator led numeric uint32 Numeric equivalents for the locator led pr...

Страница 280: ...data written since these statistics were last reset or since the controller was restarted data written numeric uint64 Unformatted data written value queue depth uint32 The number of pending I O opera...

Страница 281: ...tically created No The host entry was manually created host mapped string Yes At least one volume is explicitly mapped to the host No No volumes are explicitly mapped to the host host profile string S...

Страница 282: ...show host maps Deprecated Table 39 host view properties Name Type Description id string SAS host port WWN hba nickname string User defined name of the host port or blank host profile string Standard...

Страница 283: ...lume serial string Volume serial number lun string LUN assigned to the mapping access string no access Host is denied access to the volume not mapped The volume is not mapped read only Host has read a...

Страница 284: ...xplicitly mapped to the initiator profile string Standard Default profile host bus type string If the host was discovered and its entry was automatically created its host interface type SAS If the hos...

Страница 285: ...e initiator parameter is specified Table 42 initiator view properties Name Type Description id string For a SAS initiator its WWPN hba nickname string The nickname of the initiator host profile string...

Страница 286: ...sion mc loader string Management Controller loader firmware version sc fw string Storage Controller firmware version sc loader string Storage Controller loader firmware version serial number string Co...

Страница 287: ...seconds UTC when the controller s PCBA was programmed or a power supply module was manufactured mfg date numeric uint32 Unformatted mfg date value mfg location string City state province and country...

Страница 288: ...ational 1 Down 2 Not installed 3 Unknown health string OK Degraded Fault N A Unknown health numeric uint32 Numeric equivalents for health values 0 OK 1 Degraded 2 Fault 3 Unknown 4 N A health reason s...

Страница 289: ...ess if specified in the WBI Save Logs panel log phone string Contact s phone number if specified in the WBI Save Logs panel log comments string Comments describing the problem and specifying the date...

Страница 290: ...m manual static settings DHCP Use DHCP to obtain network address addressing mode numeric uint32 Numeric equivalents for addressing mode values 1 Manual 2 DHCP link speed string Not applicable link spe...

Страница 291: ...em will respond to a broadcast ping Disabled The system will not respond to a broadcast ping ping broadcast numeric uint32 Numeric equivalents for ping broadcast values 0 Disabled 1 Enabled Table 46 n...

Страница 292: ...tivated NTP is enabled deactivated NTP is disabled ntp server address string The current NTP server IP address if NTP is enabled The last set NTP server IP address if NTP was enabled and has been disa...

Страница 293: ...eric equivalents for port type values 8 SAS media string SAS Serial Attached SCSI target id string Port WWN status string Port status Up The port is cabled and has an I O link Warning Not all of the p...

Страница 294: ...numeric uint32 Numeric equivalents for configured speed values 0 1Gb 2 4Gb 3 Auto 7 8Gb 11 12Gb 12 16Gb health string OK Degraded Fault N A Unknown health numeric string Numeric equivalents for health...

Страница 295: ...back of the enclosure Left Right Top Bottom position numeric uint32 Numeric equivalents for position values 0 Left 1 Right 2 Top 3 Bottom part number string FRU part number dash level string FRU templ...

Страница 296: ...ason for the health state health recommendation string If Health is not OK the recommended actions to take to resolve the health issue status string Power supply status Up Warning Error Not Present Un...

Страница 297: ...basetype is used by show inquiry Table 50 product info properties Name Type Description vendor name string Vendor name product id string Product model identifier scsi vendor id string Vendor name ret...

Страница 298: ...er B controller numeric uint32 Numeric equivalents for controller values 0 B 1 A disk display string Shorthand list of the disks within a vdisk or pool disk display full string List or range of the di...

Страница 299: ...e Performance Mode 2 Active Active ULP 3 Single Controller 4 Failed Over 5 Down redundancy status string Redundant with independent cache Both controllers are operational but are not mirroring their c...

Страница 300: ...troller is down or not installed other MC status string The operational status of the Management Controller in the partner controller This is not factored into system health Not Communicating Not Oper...

Страница 301: ...e Type Description basetype name Not shown Shows when the data represented by the base type was last updated 0 The data has never been updated and is not cached nonzero number A timestamp indicating t...

Страница 302: ...ds containing running disparity errors that have been received by the PHY not including those received during Link Reset sequences A running disparity error occurs when positive and negative values in...

Страница 303: ...opology string Direct width string Number of PHY lanes in the SAS port sas lanes expected string Expected number of PHY lanes in the SAS port sas active lanes string Number of active lanes in the SAS...

Страница 304: ...id values drawer id numeric uint8 Not applicable controller string A Controller A B Controller B controller numeric uint32 Numeric equivalents for controller values 0 B 1 A wide port index uint32 The...

Страница 305: ...ed Healthy The PHY is enabled and healthy Enabled Degraded The PHY is enabled but degraded Disabled The PHY has been disabled by a user or by the system status numeric uint32 Numeric equivalents for s...

Страница 306: ...abled because of excessive PHY change counts elem reason numeric uint32 Numeric equivalents for elem reason values 0 blank 32769 Error count interrupts 32771 PHY control 32772 Not ready 32774 Drive re...

Страница 307: ...hronization and restarted the Link Reset sequence invalid dwords uint32 Number of invalid doublewords that have been received by the PHY not including those received during Link Reset sequences reset...

Страница 308: ...un Ready The schedule is ready to run at the next scheduled time Suspended The schedule had an error and is holding in its current state Expired The schedule has exceeded a constraint and will not run...

Страница 309: ...lues 0 Disabled 1 Enabled cli ssh string Disabled The secure shell CLI is disabled Enabled The secure shell CLI is enabled cli ssh numeric uint32 Numeric equivalents for cli ssh values 0 Disabled 1 En...

Страница 310: ...re update operation is active and shows the progress through each step of the operation In addition when the update operation completes status is presented indicating either the successful completion...

Страница 311: ...ceeds the critical threshold Unavailable The sensor is present with no known errors but has not been turned on or set into operation because it is initializing This typically occurs during controller...

Страница 312: ...emperature Voltage Current Charge Capacity Unknown Type sensor type numeric uint32 Numeric equivalents for sensor type values 0 Temperature 1 Current 2 Voltage 3 Charge capacity 4 Unknown Type Table 5...

Страница 313: ...ing Other MC Status other mc status string The operational status of the Management Controller in the partner controller This is not factored into system health Not Communicating Not Operational Opera...

Страница 314: ...down status properties Name Type Description controller string A Controller A B Controller B status string up The controller is operational down The controller is shut down not installed The controlle...

Страница 315: ...Warning error and critical events are sent as traps info All events are sent as traps none No events are sent as traps and traps are disabled snmp filter numeric uint32 Numeric equivalents for snmp f...

Страница 316: ...nd failed Info The command returned an informational message response type numeric uint32 0 Success 1 Error 2 Info response string A message stating what the command accomplished why the command faile...

Страница 317: ...notifications crit Sends notifications for Critical events only error Sends notifications for Error and Critical events warn Sends notifications for Warning Error and Critical events info Sends notif...

Страница 318: ...vendor name returned by the SCSI INQUIRY command scsi product id string The product identifier returned by the SCSI INQUIRY command enclosure count uint32 The number of enclosures in the system health...

Страница 319: ...orm type string Platform type platform type numeric uint32 Numeric equivalent for the platform type value platform brand string Platform brand platform brand numeric uint32 Numeric equivalent for the...

Страница 320: ...t32 Number of volumes that the system supports max vdisks uint32 Number of linear disk groups that the system supports max luns uint32 Number of LUNs that the system supports max owned arrays per cont...

Страница 321: ...used ip address mode string CAPI_TWO_IP_ADDRESSES_MODE Dual controller system has a unique IP address for each controller CAPI_ONE_IP_ADDRESS_MODE Dual controller system has the same IP address for bo...

Страница 322: ...etype properties min backing store size uint32 Not applicable max fc speed string Not applicable max fc speed numeric uint32 Not applicable Table 66 system parameters table properties continued Name T...

Страница 323: ...s Uninitialized Task is not yet ready to run Ready Task is ready to run Active Task is running Error Task has an error Invalid Task is invalid Complete The task is complete Deleted The task has been d...

Страница 324: ...minutes seconds UTC reported by the controller being accessed date time numeric uint32 Unformatted date time value time zone offset string The system s time zone as an offset in hours and minutes from...

Страница 325: ...it disk Disk enclosure Enclosure vdisk Vdisk fan CompactFlash disk slot SAS port sensor network port volume host volume map system component type numeric uint32 Numeric equivalents for component type...

Страница 326: ...equivalents for health values 0 OK 1 Degraded 2 Fault 3 Unknown 4 N A health reason string If Health is not OK the reason for the health state health recommendation string If Health is not OK the reco...

Страница 327: ...le cache Table 70 unwritable cache properties Name Type Description unwritable a percentage uint8 The percentage of cache space occupied by unwritable data in controller A unwritable b percentage uint...

Страница 328: ...Korean interface access WBI string x User can use the web browser interface blank User cannot access this interface interface access CLI string x User can use the command line interface blank User ca...

Страница 329: ...es 0 Fahrenheit 1 Celsius timeout uint32 Time in seconds that the session can be idle before it automatically ends Valid values are 120 43200 seconds 2 720 minutes authentication type string For an SN...

Страница 330: ...SNMPv3 user whose privacy type is set to DES or AES trap destination string For an SNMPv3 user whose interface access SNMP property is set to snmptarget this specifies the IP address of the host that...

Страница 331: ...data written value total bytes per sec uint64 Data transfer rate in bytes per second since the last sampling time This is the sum of read bytes per second and write bytes per second total bytes per se...

Страница 332: ...data read value data written uint64 Amount of data written since these statistics were last reset or since the controller was restarted data written numeric uint64 Unformatted data written value avg...

Страница 333: ...ontroller loader firmware version capi version string Configuration API CAPI version mc fw string Management Controller firmware version mc loader string Management Controller loader firmware version...

Страница 334: ...ype is used by show vdisk statistics when the historical parameter is specified Table 75 virtual disk summary properties Name Type Description name string Vdisk name serial number string Vdisk serial...

Страница 335: ...he partner controller when the preferred owner is offline A Controller A B Controller B owner numeric uint32 Numeric equivalents for owner values 0 B 1 A preferred owner string Controller that owns th...

Страница 336: ...Quarantined critical The vdisk is critical with at least one inaccessible disk For example two disks are inaccessible in a RAID 6 vdisk or one disk is inaccessible for other fault tolerant RAID level...

Страница 337: ...ning on the vdisk if any blank No job is running DRSC A disk is being scrubbed EXPD The vdisk is being expanded INIT The vdisk is initializing RCON The vdisk is being reconstructed VRFY The vdisk is b...

Страница 338: ...ype values 1 MIX 4 SAS 8 sSAS 11 SAS MDL is job auto abortable string false The current job must be manually aborted before you can delete the vdisk true The current job will automatically abort if yo...

Страница 339: ...alth values 0 OK 1 Degraded 2 Fault 3 Unknown 4 N A health reason string If Health is not OK the reason for the health state health recommendation string If Health is not OK the recommended actions to...

Страница 340: ...API basetype properties volume names This basetype is used by show volume names Table 77 volume names properties Name Type Description volume name string Volume name serial number string Volume serial...

Страница 341: ...older Exclusive Access Certain access read write commands are only allowed for a single reservation holder Write Exclusive Registrants Only Write commands are only allowed for registered hosts There i...

Страница 342: ...r The volume is in a linear pool storage type numeric uint32 Numeric equivalents for storage type values 0 Linear preferred owner string Controller that owns the volume during normal operation A Contr...

Страница 343: ...Adaptive Adaptive read ahead is enabled which allows the controller to dynamically calculate the optimum read ahead size for the current workload Stripe Read ahead is set to one stripe The controller...

Страница 344: ...fault wwn string World Wide Name of the volume progress string Not applicable progress numeric uint32 Unformatted progress value container name string Vdisk name container serial string Vdisk serial n...

Страница 345: ...alth numeric uint32 Numeric equivalents for health values 0 OK 1 Degraded 2 Fault 3 Unknown 4 N A health reason string If Health is not OK the reason for the health state health recommendation string...

Страница 346: ...was restarted data read numeric uint64 Unformatted data read value data written uint64 The amount of data written since these statistics were last reset or since the controller was restarted data wri...

Страница 347: ...and time in the format year month day hour minutes seconds when these statistics were last reset either by a user or by a controller restart reset time numeric uint32 Unformatted reset time value sta...

Страница 348: ...n durable id string Volume ID in the form V where starts at 1 and increments for each new volume to uniquely identify it The value is generated from available data in the current CLI session and may c...

Страница 349: ...epresented in the group Blank if not mapped or mapped as no access access string no access Host is denied access to the volume not mapped The volume is not mapped read only Host has read access to the...

Страница 350: ...TTPS Debug In band SES Activity Progress Reporting Enabled Enabled Enabled Enabled Disabled Enabled Disabled Enabled Disabled Users All configured users are deleted and replaced with default user defi...

Страница 351: ...e back Disk background scrub Disabled Enabled High preserved 7 Disabled 5 seconds Enabled Enabled Enabled Disabled Native Command Queuing NCQ Enabled Managed Logs Disabled 1 Factory default no tasks o...

Страница 352: ...mode automatically changes from write back to write through CAPI Configuration Application Programming Interface A proprietary protocol used for communication between the Storage Controller and the Ma...

Страница 353: ...CRC DAS Direct Attached Storage A dedicated storage device that connects directly to a host without the use of a switch Data Encryption Standard See DES dedicated spare A disk that is reserved for us...

Страница 354: ...tion failover is the act of temporarily transferring ownership of controller resources from an offline controller to its partner controller which remains operational The resources include volumes cach...

Страница 355: ...at specifies no access to that volume by hosts See also default mapping and explicit mapping MC Management Controller A processor located in a controller module that is responsible for human computer...

Страница 356: ...Monitoring Analysis and Reporting Technology See SMART serial electrically erasable programmable ROM See SEEPROM Service Location Protocol See SLP SES SCSI Enclosure Services The protocol that allows...

Страница 357: ...which the world regulates clocks and time It replaces Greenwich Mean Time UTF 8 UCS transformation format 8 bit A variable width encoding that can represent every character in the Unicode character se...

Страница 358: ...it 58 output formats 12 scripting commands 13 scripting guidelines 17 set base for storage space sizes 90 set locale 91 set output format 90 set paging mode 91 set precision 91 set prompt 112 set temp...

Страница 359: ...t performance statistics 73 set policy for degraded 95 set spin down delay 86 99 show data transfer rate 148 264 show disk scrub setting 126 show information 145 show maximum number of 191 show parame...

Страница 360: ...set 84 show setting 125 host channel See host ports host link See host ports host ports reset 74 reset performance statistics 75 show 164 174 show number of 191 show performance statistics 166 hosts s...

Страница 361: ...olation 102 enable disable specific 103 show performance statistics 165 ping enable disable response to broadcast 109 ping a remote host 66 port syntax 20 ports show health for SAS 183 show provisioni...

Страница 362: ...lobal spares 126 show setting for available disks and global spares 126 SSH interface enable disable 113 statistics reset all performance 70 reset controller performance 71 reset disk error 72 reset d...

Страница 363: ...ormance statistics 76 set interval for background 84 show 197 show maximum number of 191 show maximum number per controller 191 show performance statistics 200 show provisioning 178 start manual scrub...

Отзывы: