show cache-parameters 129
Cache Flush
•
Enabled
: If the controller loses power, it will automatically write cache data to the
CompactFlash card. Cache flush is normally enabled, but is temporarily disabled during
controller shut down.
•
Disabled
: Cache flush is disabled.
Volume cache parameters:
Serial Number
If a volume is specified, its serial number.
Name
If a volume is specified, its name.
Cache Write Policy
If a volume is specified, its cache write policy:
•
write-back
: Write-back caching does not wait for data to be completely written to disk before
signaling the host that the write is complete. This is the preferred setting for a fault-tolerant
environment because it improves the performance of write operations and throughput. This is the
default.
•
write-through
: Write-through caching significantly impacts performance by waiting for data
to be completely written to disk before signaling the host that the write is complete. Use this
setting only when operating in an environment with low or no fault tolerance.
Cache Optimization
If a volume is specified, its cache optimization mode:
•
standard
: Optimizes cache for both sequential and random reads. Appropriate for
applications that read and write small files in random order, such as transaction-based and
database update applications. This is the default.
•
no-mirror
: When this mode is enabled, each controller stops mirroring its cache metadata to
the partner controller. This improves write I/O response time but at the risk of losing data during
a failover. ULP behavior is not affected, with the exception that during failover any write data in
cache will be lost.
Read Ahead Size
If a volume is specified, its read-ahead cache setting:
•
Disabled
: Read-ahead is disabled.
•
Adaptive
: Adaptive read-ahead is enabled, which allows the controller to dynamically
calculate the optimum read-ahead size for the current workload.
•
Stripe
: Read-ahead is set to one stripe. The controllers treat non-RAID and RAID-1 vdisks
internally as if they have a stripe size of 512 KB, even though they are not striped.
•
512 KB
,
1 MB
,
2 MB
,
4 MB
,
8 MB
,
16 MB
, or
32 MB
: Size selected by a user.
Example
Show the cache parameters for the system and for volume
V1
.
# show cache-parameters V1
Basetypes •
•
•
See also •
•
Содержание AssuredSAN 6004
Страница 11: ...Document conventions and symbols 11 TIP Provides helpful hints and shortcuts...
Страница 58: ...58 Alphabetical list of commands exit Description Log off and exit the CLI session Min role monitor Syntax exit...
Страница 107: ...set led 107 Identify drawer 1 in enclosure 1 set led drawer 1 1 on Identify fan 1 in enclosure 1 set led fan 1 1 on...
Страница 114: ...114 Alphabetical list of commands See also set cli parameters show protocols...
Страница 139: ...show controller statistics 139 See also reset all statistics reset controller statistics...
Страница 153: ...show disk statistics 153 See also reset all statistics reset disk error statistics reset disk statistics show disks...
Страница 162: ...162 Alphabetical list of commands See also show power supplies...
Страница 207: ...show volume reservations 207 Basetypes volume reservations status See also release volume show volumes...