Appendix B – MANET recessed pull grips
Follow these instructions in addition to the Installation
and Maintenance Instructions in order to avoid damage
of product or property and injury to persons.
NOTICE
All users have to be informed about relevant
points referenced in these safety-related
instructions and the Installation and
Maintenance Instructions.
B.1.1 General information.
1. dormakaba recommends using TSG-H (heat soaked
toughened safety glass) to DIN EN 12150-1).
2. dormakaba glass fittings are not suitable for
applications in rooms where chemicals (e.g. chlorine)
are used, such as in indoor swimming pools, saunas,
or salt water pools.
3. Never move sliding glass panels faster than walking
speed and always stop the door manually before it
reaches the end position.
B.1.2 Mounting
1. Only properly qualified and specially trained staff
are authorized to mount dormakaba glass fittings.
2. Never use glass with conchoidal fractures and/or
damaged edges.
3. Due to crushing hazards, among others in the area
of the secondary closing edge, and possible injury
caused by the breakage of glass during mounting,
corresponding protective clothing (especially gloves
and protective goggles) are required.
4. Before mounting the glass fitting, clean clamping
area with fat solvent (standard commercial cleaning
agent).
5. Never use clamping shoes on structured glass
surfaces (except on satined glass) or glass of heavily
varying thickness unless used with a corresponding
leveling layer.
6. Never use clamping shoes on self-cleaning coatings.
7. When adjusting glass elements, always maintain the
required clearance for the respective fitting.
Adjust clearance so that the glass does not touch
hard components such as glass, metal or concrete.
8. Make sure not to use excessive force when installing
the glass (avoid local stress resulting from very tight
screws).
B.1.3 Maintenance
1. Check fittings at regular intervals for proper
positioning and smooth running.
2. Check door for correct adjustment.
3. Highly used door systems require inspection by
properly qualified staff (specialized companies or
installation firms).
4. Immediately replace damaged glass elements (no
glass flaking and/or conchoidal fractures)!
5. Only use suitable cleaning and care products to
clean the surfaces.
B.1 Safety-related information for the mounting and use of dormakaba
glass fittings