35
CS 80 MAGNEO
10-2022
DL3316-010
Installation and Maintenance Manual
Chapter 5
5.6 Safety
functions
Static forces in Low-Energy mode.
The system does not exceed a value of 15 lbf [67 N]
during opening and closing cycles.
Opening cycle
As soon as the door hits an obstacle during an opening
cycle, it will immediately stop and remain in its position
for 3 seconds. Then the operator will try to continue the
opening cycle.
If the door hits the obstacle three times during an
opening cycle, it will close.
Closing cycle
When the door panel hits an obstacle while closing, it
will immediately stop and perform an opening cycle.
5.7 Safety sensors
Sensors can be installed to detect obstacles. An
automatic sensor test can be activated or deactivated
via the DIP switches located inside the operator.
Opening cycle.
The door will stop immediately when the sensor detects
an obstacle during an opening cycle and will continue
the cycle as soon as the object has been removed. In
case the obstacle has not been removed, the door will
close on completion of the adjusted hold-open time.
Closing cycle.
The door will stop immediately and reverse when the
sensor detects an obstacle during the closing cycle.
Door in closed position.
This function is not activated while the door is in the
closed position (then the sensor is deactivated).