40
CS 80 MAGNEO
10-2022
DL3316-010
Installation and Troubleshooting Manual
Chapter 8
8 Installation instructions for on-wall
mounting
8.1.1 Mounting procedure.
If there is a door frame, the angle bracket must be
shimmed with a shim plate (Para. 8.1.7).
1. Auxiliary lines for positioning purposes (Para. 8.1.2).
2.1 Installation without shim plate (Para. 8.1.5).
2.2 Installation with shim plate (Para 8.1.7).
8.1.2 Positioning guide.
1. For installation without shim plate mark the center
of passage on the wall.
2. For installation with shim plate mark center of
passage on the wall.
• Refer to Table 8.1.1 for required
M
dimension for the
operator reference line.
• L corresponds to operator length.
3. Mark the reference line (Fig. 8.1.3).
• Always mark the reference line on the side of the
main closing edge (Fig. 8.1.4).
**
34.4" [875]
39.4" [1000]
44.3" [1125]
C
22.7" [575]
27.6" [700]
32.5" [825]
L
68.9" [1750]
78.7" [2000]
88.6" [2250]
M
17.2" [437.5]
19.7" [500]
22.1" 562.5]
TIPS AND RECOMMENDATIONS
In case the door panel is not positioned in the
center of the passage, the bracket or shim
plate must be shifted by the desired dimension.
Fig. 8.1.1 Glass door panels with MANET single-point
attachment
M
=
=
Main closing edge
R
e
fe
renc
e
line
Fig. 8.1.3 Reference line
Table 8.1.1
Max. passage width, C, L and M dimensions
Fig. 8.1.2 Door panel information
Main closing edge
Secondary closing edge
Fig. 8.1.4 Main closing edge
8.1 Mounting
procedure
Edge grinded glass
=
=
CENTERED
2.5" [63 mm]
2.2" [55 mm]
Min. 2.76"
Min 70 mm]
Glass heigh
t
= H - 5” [
12 mm]
Ø1.03” [Ø26 mm] hole
CSink Ø1.26” [Ø32 mm] x 90⁰
“Closed” side
Glass width
Drill hole for
recessed door grip
(optional)
Ø0.1.97” [Ø50 mm] hole
CSink Ø2.05” [Ø52 mm] x 90⁰
C
90⁰
90⁰
Min. 0
.2”
Min. 5 mm
2.
5
”
62 mm
Max.
.31”
8 mm
.250”
6 mm
Finished floor
Angle floor guide rail
compl.
**
Maximum passage width.