51
CS 80 MAGNEO
10-2022
DL3316-010
Installation and Troubleshooting Manual
Chapter 9
9.1.9
Connection of 120 Vac permanent power
supply.
WARNING
Work on electrical equipment must only be
performed by properly qualified personnel
(electricians).
Before starting installation, make sure that
the 120 Vac power supply is OFF.
1. Loosen the end stop and move it to the center of the
system (Ref. Chapter 7, Fig. 7.3).
2. Cut the wires to length, strip the wire insulation
(1/4" [6 mm]).
3. Connect L1 and N to the terminals of the power
supply.
4. Reference Para.9.1.11 for grounding wire connection.
9.1.10 Conduit
connection.
When using a conduit connection, use the supplied
conduit cover, mounting plate and Phillips screws.
1. Attach mounting plate to operator with 2 screws.
2. Route the wires through the mounting plate and
connect to the operator.
3. Fold the conduit cover as shown.
4. Secure conduit cover to mounting plate with
remaining screw.
9.1.11 Grounding wire (PE) connection to power supply.
1. Using a screwdriver, open the control unit housing
cover.
2. Route the grounding wire through the operator
control unit housing and connect it to the grounding
terminal (PE).
WARNING
The grounding wire must be connected to the
PE terminal.
9.1.12 Connection of external accessories.
1. Connect all external accessories except for safety
sensors. Refer to cable channel instructions.
9.1.13 Close
control
unit cover, move and secure end
stop.
1. Close cover of control unit housing.
2. Secure the cover with control unit housing cover screw.
3. Move end stop to end of channel and tighten end stop
screws.(Ref. Chapter 7, Fig. 7.7).
Fig. 9.1.9 Connection of 120 Vac permanent power supply
L1
N
L1
N
L1
N
6”
[150 mm]
1/4”
[6 mm]
1 3/8”
[35 mm]
1/4”
[6 mm]
Fig. 9.1.10 Conduit connection
1.
3.
2.
5.
4.
Fig. 9.1.11 Grounding wire (PE) connection to power supply
1.
2.
3.
1.
2.
3.
Fig. 9.1.12 Close and secure cover, secure end stop