48
CS 80 MAGNEO
10-2022
DL3316-010
Installation and Troubleshooting Manual
Chapter 9
9 Installation instructions – in-wall mounting
9.1 Installation
instructions
9.1.1 Minimum recess for CS 80 MAGNEO operator.
The CS80 MAGNEO sliding door operator is also
suitable for an "invisible" in-wall mounting.
For this type of mounting, a recess with a minimum
width of 2" [50 mm] and a depth of 2.95" [75 mm] is
required.
A special door frame manufactured by BOSS can be
used. Contact dormakaba for additional details.
9.1.2 Installation dimensions.
NOTICE
Dimension X
• When using a Wooden door panel:
X = door panel 3" [78 mm].
• When using a glass clamping rail:
X = door panel 4 1/2" [114 mm].
• When using dormakaba MANET single
point fixings:
X = door panel 2 29/32" [74 mm].
2" [50 mm]
]
m
m
5
7[
"
5
9.
2
Fig. 9.1.1
Minimum recess, in-wall mounting
Table 9.1.1
Installation dimensions
L
68.9" [1750 mm]
78.7" [2000 mm]
88.6" [2250 mm]
M
17.2" [437.5 mm]
19.7" [500 mm]
22.1" 562.5 mm]
A
73.6" min.
[1750 mm] min.
83.5" min.
[2120 mm] min.
73.6" min.
[2370 mm] min.
C
22.7" [575 mm]
27.6" [700 mm]
32.5" [825 mm]
A = minimum L + 4.72” [120 mm]
L
2” min.
[50 mm] min.
2.75” min.
[70 mm] min.
Bottom edge of header
2
.75” min.
[7
0 mm] min.
C
Centered
=
=
M
“Closed” position
2
.50” .
[63.5 mm]
X
Dimension
X
must be
measured at the highest point
of floor within movement
range of door system,
• Dimension
L
: Operator length.
• Dimension
M
: Distance from center of passage area.
to side of operator where connections are located.
• Dimension
A
: Minimum width between frames.
• Dimension
X
: Height of top of operator from floor.
Fig. 9.1.2 Door system installation dimensions
CAUTION
Holes for cables must be sufficiently large
and must not have sharp edges.
TIPS AND
RECOMMENDATIONS
The wall must not be
closed before the
system has been
installed.