73
CS 80 MAGNEO
10-2022
DL3316-010
Installation and Troubleshooting Manual
Appendix C
Appendix C – Power Fail Locking
NOTICE
In conjunction with an electromechanical
locking device, an external program switch is
required.
C1.1
When program switch set to "OFF", the
operator closes and locks the door.
C1.2
Whenever an opening pulse is triggered at the
"internal activator" (terminals 3 and 42), the
locking device unlocks and the operator opens
the
door.
C1.3
On expiration of the adjusted hold open time,
the operator closes and locks the door.
C.1 Functional
description
WARNING
Safety instructions ( ) "Mounting
instructions and instructions for use of
operator" must be observed.
C.2 Mounting
NOTICE
Preparation of mounting:
1) Determine"closed" position.
2) Mount drive unit.
3) Attach door panel and move door to
"closed" position.
C2.1 Overview: Removing end stop attachment screws
and end stop.
1. Carefully pull out carrier until the attachment
screws of the "stop" are visible.
2. Remove end stop screws; remove end stop.
Reference Para. C2.2 through C2.9 for step by step
instructions.
C1.5
An opening pulse at the "external activator"
(terminals 3 and 41), has no effect while the
program switch is set to "OFF".
These terminals are only activated while the
program switch is set to "AUTOMATIC" mode
(reference operating instructions).
C1.6
In the event of a power failure, the locking
device unlocks so that users may manually open
the
door.
1.
3.
2.
Fig. C2.1 End stop attachment screw removal