64
CS 80 MAGNEO
10-2022
DL3316-010
Installation and Troubleshooting Manual
Appendix A
Appendix A – MAGNEO Single MANET
ON-WALL
Operator
Package
A.1
MAGNEO Operator single door package.
A. Operator:
• Angle bracket to mount MAGNEO on wall.
• Low profile aluminum header.
• MANET kit for glass door panel.
• 3/8" [10] to 1/2" [13] Solid Tempered glass
required (provided by others).
• Floor mounted bottom guide.
B. Header length includes:
• MAGNEO, covers and end caps.
C. Connection kit:
• #10 x 2" [51] SPAX flathead Phillips screws to
mount wall angle bracket.
• 5/16" - 24 x 3/8" [10] socket head cap screws to
mount header.
• Shim kit.
A.2 Finishes
A. Extruded cover:
• Clear anodized (BHMA 204), customer anodized,
custom painted or cladding.
B. End caps - painted silver.
C. MANET panel hanging hardware - stainless steel.
A.3
Typical package options.
A. Concealed lock.
(DK3588-010)
B. Electronic bolt kit.
(DK3305-0_G)
C. Recessed door grip.
(DK3309-01G)
D. Elegant Touch/Touchless
(DX3337-0_ _)
Activation
E.
Ladder
pulls
(DK3308-0_G)
F. Other pull handles: Reference applicable door
hardware
manual.
A.4 Drawing
notes.
A. Drawing dimensions are in English & Metric units.
Metric units are displayed as: 1" [24] millimeters.
B. Operator lengths are fixed (Ref. Table A1.1).
C. Operator weight: 23 lb [80 kg].
D. Maximum panel weight: 175 lb [80 kg].
• 3/8" glass = Max. 36 ft
2
• 1/2" glass = Max. 27 ft
2
A.5 Power
requirements.
A. 115 Vac, 50/60 Hz, 15 A max., 14 AWG (per operator).
A.6
Standards of compliance.
A. UL 325 & CSA 22.2 (listed with ETL).
B. Designed to comply with these standards depending
on installation and application.
• International Building Code (Section 1008).
• ANSI/BHMA 156.10 (Requires additional overhead
activation and safety sensors).
• ANSI/BHMA 156.38 (Requires additional knowing
activation sensors).
• NFPA 101 Life Safety Code (Section7.2.1.9).
C. For egress minimum door height and minimum/
maximum width requirements, refer to Local, State,
National or AHJ Building Code.
A.7
Contact dormakaba Architectural Services for
additional information:
A. Email: [email protected]
B. Phone: 1-844-SPEC-NOW (1-844-773-2669)
NOTICE
THIS PRODUCT DOES NOT BREAKOUT; NOT
INTENDED FOR EMERGENCY EGRESS.
MAGNEO available in three (3) fixed sizes (By operator length)
Operator
Length
Min. Clear
Opening
Max. Clear
Opening
Overall
Header Length
Fixed Panel
Mounts
End Bracket
Location
Center Bracket
Location
68.90" [1750]
25" [635]
32" [813]
72.42" [1840]
22.64" [575]
66.73" [1695]
34.45" [875]
78.74" [2000]
30 3/8" [ 937]
36 7/8" [937]
82.28" [2-90]
27.56" [700]
76.57" [1945]
39.37" [1000]
88.58" [2250]
34 1/4" [870]
41 3/4" [1061]
92.11" [2340]
32.48" [825]
86.42" [2195]
44.30" [1125]
Table A.1 MAGNEO fixed sizes
Operator
Length
Minimum
Travel
Maximum
Travel
Minimum Panel
Width
68.90" [1750]
27.56" [700]
34.45" 875]
30" [762]
78.74" [2000]
32.87" [835]
39.37" [1000]
35.39" [899]
88.58" [2250]
36.81" [935]
44.30" [1125]
39.33 [999]
Shown in Fig. A1.1