29
Manual for PC connection setting_DV55.fm
J
Devices required for data communication
(OBEX
™
communication)
To perform data communication, downloading data
transfer software complied with OBEX
™
standard from
the Internet, and installing this software to your PC is
necessary. Refer to the software manual for
information on operating environment and installation
methods. In addition, installation of the FOMA
communication setting file (
n
P. 4 to P. 6) is
necessary beforehand.
A FOMA USB Cable with Charge Function 01/02 is
required to connect the FOMA terminal to a PC.
Send data from a PC to a FOMA terminal one item at a
time.
Sending one item at a time from a FOMA terminal to a
PC is not possible.
Data transfer operating methods differ depending on
the software used. Refer to the software manual for
details.
1
Send data from a PC using data
transfer software (Write 1).
Refer to the software manual for details on
sending data.
Write and read all data at once, between a PC and the
FOMA terminal.
“Write all” and “Read all” operations require data
transfer software and your FOMA terminal
authentication password.
Data transfer operating methods differ depending on
the software used. Refer to the software manual for
details.
1
Send data from a PC using data
transfer software (Forward all).
Refer to the software manual for details on
sending data.
Entering your authentication password on the
PC will be necessary.
Enter your authentication password (four digits).
2
Enter the terminal security code (four
to eight digits) and the authentication
password (four digits).
3
Start data transmission.
Mail with i-
a
ppli start up designations can be sent
after attached data has been deleted.
Mail attachment data exceeding 100 KB (including
the message text) are deleted and only message is
sent.
Data such as phonebook entries cannot be sent or
received while All lock is set. Data of locked functions
cannot be received while Function lock is set.
Phonebook data cannot be sent or received when
Keypad dial lock is set.
Depending on data size, data communication may
take some time. In addition, the FOMA terminal may
not be able to receive data due to data size.
When receiving phonebook data, data will be added
from memory number [010] for single entry, or in
accordance with memory number information when
receiving all entries.
When receiving all phonebook entries, Owner
information (excluding first phone number) registered
in Own number will be overwritten.
Phonebook entries are sent in memory number order.
When sending all phonebook entries, Owner
information from own number screen is also sent.
PDF files which exceed 2 MB cannot be sent.
Alternatively, send and receive data (OBEX) with the
following methods.
Ir exchange
iC transmission
microSD Card
Bluetooth communication
Note
The FOMA terminal data communication (OBEX
™
communication) function complies with IrMC
™
1.1
standard. However, depending on the application,
some data may not be sent or received even when
the other party’s terminal complies with IrMC
™
1.1
standard.
Sending single data item (Write 1)
Note
Note
When phonebook data is sent (from a PC to the
FOMA terminal handset) one entry at a time, entries
are saved to the smallest available memory number
from [010] to [999]. If all memory numbers from [010]
to [999] are already used, entries are saved to the
smallest available memory number between [000]
and [009].
When phonebook data is received and 1,000 entries
(names, phone numbers, or mail addresses) are
already registered, or more than 1,000 entries have
been registered, a message appears notifying that
no further entries can be saved.
Sending all data (Write all/Read all)
Note
Performing Write all from a PC to your FOMA
terminal replaces all data stored in the FOMA
terminal. All data previously stored in your FOMA
terminal will be deleted. This includes phonebook,
schedule, and protected mail data saved as secret
data.
If an error occurs during data transmission from a PC
to the FOMA terminal, all data stored in the FOMA
terminal may be deleted. Check the cable
connection, the FOMA terminal battery level, and the
PC power supply before performing Write all.
Performing operations while charging the FOMA
terminal in the desktop holder is recommended.
Depending on the connected device, the
transmission status (bar display) may not appear.
Manual for PC connection setting_DV55.fm 29 ページ 2008年5月6日 火曜日 午前8時55分
Содержание FOMA SH906i
Страница 1: ... 08 5 08 5 08 5 1st Edition TINSEA160AFZZ 08E 2 42 DS SM548 1 ...
Страница 196: ...e09_dv55_7e fm 194 194 194 LMEMO9 dv55_E book 194 ページ 2008年5月6日 火曜日 午前8時59分 ...
Страница 254: ...e11_dv55_7e fm 252 252 252 LMEMO9 dv55_E book 252 ページ 2008年5月6日 火曜日 午前8時59分 ...
Страница 266: ...e12_dv55_7e fm 264 264 264 LMEMO9 dv55_E book 264 ページ 2008年5月6日 火曜日 午前8時59分 ...
Страница 520: ...e23_dv55_7e fm 518 518 518 LMEMO9 dv55_E book 518 ページ 2008年5月6日 火曜日 午前8時59分 ...
Страница 521: ...e24_dv55_7e fm 519 533 519 Index Quick Manual Index 520 Quick Manual 534 dv55_E book 519 ページ 2008年5月6日 火曜日 午前8時59分 ...
Страница 548: ... 08 5 08 5 08 5 1st Edition TINSEA160AFZZ 08E 2 42 DS SM548 1 ...
Страница 592: ...区点コード一覧_dv55_E fm Kuten Code List 08 4 1st Edition 区点コード一覧 _dv55_E fm 0 ページ 2008年5月6日 火曜日 午前8時57分 ...