Read selected positon in database:
[CC]GREC,X<CR LF>
Instrument’s answer:
[CC]GREC,X,PPPP<CR LF>
In which:
X
database index:
0 customer database
1 material database
2 input text database
3 vehicle database
PPPP
Position number selected in the database
( NULL if no position has been selected)
Reading of compiled positions and total number of positions in the database:
[CC]NREC,X<CR LF>
Instrument’s answer:
[CC]NREC,X,CCCC,TTTT<CR LF>
In which:
X
database index:
0 customer database
1 material database
2 input text database
3 vehicle database
CCCC
Number of compiled positions in the database
TTTT
Total number of available positions in the database
5.8 ALIBI MEMORY
The memorisation of a weigh takes place:
Following the reception of a command through the serial line,
.
Upon the printing made with the F5 key or upon totalisation
By setting the
SEtuP >> SEriAL >> CoMPrn >> ProtoC
parameter on "Alibi"
.
It’s possible also to transmit the string (weigh/ID) on the PC port, by setting the
SEtuP >> SEriAL >> CoMPC >>
ProtoC
parameter on "Alibi"
.
The string is transmitted in the same format of the string received in response to the “WEIGHT VALUE REQUEST
WITH WEIGH ID” command.
The identification of the weigh takes place through the ID code; a code is given to each weigh, allowing finding the weigh in
the database.
If the weight can be saved in the alibi, the numeric ID will be substituted with the message "NO".
The ID has the following format:
<Rewriting number > — < Weigh number >
- Rewriting number: number of 5 digits which may go from 0 to 00255; it indicates the number of complete rewritings of
the alibi memory.
- Weigh number: number of 6 digits which may go from 0 to 131071; it indicates the weigh number in the current rewriting
of the alibi memory
With each storage the weigh number is increased of 000001; when this reaches the value 131071, it restarts from 000000
and the rewriting number increases of 00001.
If the weigh can not be saved in the alibi, the numeric ID will be substituted with the message "NO".
For example:
If the weigh which has been stored is the following:
“PIDST,1,
1.000kg,
1.000kg,00126-131071”
the following will be:
“PIDST,1,
1.000kg,
1.000kg,00127-000000”